Event Notification Report for October 14, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/13/2000 - 10/14/2000

EVENT NUMBERS
3742937430374313760339299

Power Reactor
Event Number: 37429
Facility: COOPER
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: WILLIAM GREEN
HQ OPS Officer: LEIGH TROCINE
Notification Date: 10/14/2000
Notification Time: 05:14 [ET]
Event Date: 10/14/2000
Event Time: 03:24 [CDT]
Last Update Date: 10/18/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
DAVE LOVELESS (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC REACTOR SCRAM DUE TO A MAIN GENERATOR TRIP FOR UNKNOWN REASONS

The following text is a portion of a facsimile received from the licensee:

"At 0324 [CDT], a reactor scram occurred due to a main generator trip. Group isolations 2, 3[, and] 6 occurred due to low reactor water level. The lowest [reactor water] level recorded was -20 inches on [the] wide range level recorder. Reactor water level recovered, and both reactor [feedwater] pumps tripped on high reactor water level. Group isolations have been verified and reset. [The] 'A' reactor [feedwater] pump has been returned to service and is being used to control water level. [High pressure coolant injection] and [reactor core isolation cooling] did not inject and were not needed to control reactor water level. The plant will be placed in Cold Shutdown. The electrical grid is stable."

The licensee stated that all control rods fully inserted and that all systems functioned as required. The licensee also stated that alternate rod insertion initiated as a result of high pressure due to the transient. The highest pressure observed was 1,085 psi. None of the relief valves lifted, and the main steam isolation valves remained open throughout the event. Steam is currently being dumped to the condenser.

In addition, the licensee stated that the cause of the main generator trip is currently under investigation. There were no related surveillance or maintenance activities ongoing at the time of the event.

The licensee notified the NRC resident inspector.

* * * UPDATE on 10/18/00 at 0428 ET by Myers taken by MacKinnon * * *

A detailed review of the plant response to the scram has been conducted. This review indicated the following clarification to the initial report are needed:

Alternate Rod Insertion initiated on low level, rather than high pressure. The low level was not in long enough to trip the Recirculation pumps. The pumps trip after a 9 second delay, and the low level signal was only in for ~ 7 seconds.

Initial indications were that reactor pressure had reached 1085 psig, based on pressure recorder LRPR97, the highest reading of the pressure recorders. Additional pressure recorders and the plant computer indicate pressure reached a maximum of ~ 1068 psig. Evaluation of the recorder indicates it is in calibration, and the "overshoot" of indicated pressure is due to mechanical characteristics of the recorder linkage. NRC R4DO (John Pellet) notified.

The NRC Resident Inspector was informed of this update by the licensee.


Power Reactor
Event Number: 37430
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: THOMAS O'QUINN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/14/2000
Notification Time: 18:50 [ET]
Event Date: 10/14/2000
Event Time: 18:30 [EDT]
Last Update Date: 10/14/2000
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED 50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
KEN BARR (R2)
BRUCE BOGER (NRR)
BELCHER (FEMA)
JOHN JOLICOEUR (RCT)
C. MILLER (IRO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
UNUSUAL EVENT DECLARED AT 1830 HOURS DUE TO FIRE IN THE PROTECTED AREA LASTING GREATER THAN 10 MINUTES.

"2A" Heater Drain Pump motor fire reported. Fire reported at 1815 hours, the area was secured and the fire was extinguished using carbon dioxide by the onsite fire brigade at 1831 hours. No injuries. Offsite fire department assistance was initially requested by the licensee but was not needed to extinguish the fire. Damage caused by the fire was the top back of the heater drain pump motor. Plant operation was not affected by the fire. Emergency facilities on site were not activated. State and local counties were notified by the licensee.

After "2A" Heater Drain Pump tripped "2C" Heater Drain Pump was started.

The NRC Residence Inspector was notified of this event by the licensee.

* * * UPDATE on 10/14/00 at 1912ET by Schall taken by MacKinnon * * *

Unusual Event terminated at 1908 ET. R2DO (Ken Barr), FEMA (Belcher), IRO (C. Miller).

The NRC Resident Inspector was notified by the licensee.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37431
Facility: CATAWBA
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: PAUL McINTYRE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 10/15/2000
Notification Time: 01:42 [ET]
Event Date: 10/14/2000
Event Time: 16:40 [EDT]
Last Update Date: 10/15/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iv)(A) - AIRBORNE RAD RELEASE
Person (Organization):
KEN BARR (R2)
BRUCE BOGER (NRR)
JOSEPH GIITTER (IRO)
ROGER PEDERSON (HP)
STU BAILEY (DOE)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
UNPLANNED, MONITORED, RADIOACTIVE RELEASE OF NOBLE GASES THROUGH THE UNIT VENT DURING ALIGNMENT FOR SAMPLING OF THE REACTOR COOLANT SYSTEM PRESSURIZER STEAM SPACE WHILE ENTERING A REFUELING OUTAGE

The following text is a portion of a facsimile received from the licensee:

"[Based on preliminary data, the licensee reported that an] airborne radioactive release that may have exceeded the reportability limits in Appendix 'B' of 10 CFR [Part] 20, Table 2. Preliminary results from data available as of 2200 hours on 10/14/00 appear to indicate that the release has exceeded the reportability criterion. Additional review and calculation of preliminary results are in progress to determine the actual release. Followup notification will be made to validate or retract this notification."

The licensee reported that this unplanned, monitored, gaseous, offsite release occurred at 1640 on 10/14/00 and that it was terminated within approximately 20 minutes. The weather conditions were very stable at the time. The site boundary dose and noble gas release rate were not available at the time of the event notification. However, the available data indicated the dose at the unit vent. Two radiation monitors exceeded their Trip II setpoints.

Plant Stack Other
EMF 36 EMF 41

Radiation Monitor Readings 3.63 E3 cpm 2.24 E4 cpm
Alarm Setpoints: Trip II 2.71 E3 cpm 4.54 E3 cpm
Percent of Technical Specification Limit Not Available Not Available

The licensee stated that there is no direct correlation between the radiation monitor setpoints or readings and the technical specification limits. The technical specification limits are based upon dose at the site boundary, and determination of the site boundary dose requires extensive calculations and review. The licensee currently anticipates that this information will be available in the followup notification. At this time, the licensee believes that the release was well below the technical specification limits. The licensee stated that nothing was unusual or misunderstood and that all systems functioned as required.

The licensee plans to notify the NRC resident inspector, the States of North Carolina and South Carolina, and the applicable counties (York, Gaston, and Mecklenburg). The licensee does not plan to issue a press release, and media interest is not anticipated at this time.

HOO NOTE: At 0735 and 0818 on 10/15/00, representatives from the Environmental Protection Agency (Paul Wagner) and the South Carolina Department of Health and Environmental Control (John Jesse), respectively, called the NRC Operations Center for information regarding this event. (Call the NRC operations officer for contact information.)

* * * UPDATE ON 10/15/00 @ 1438 BY FRITZ TO GOULD * * * RETRACTION

The Radiation Protection staff have evaluated the release and determined that it did not exceed any limits and also did not meet any reporting requirements of 10 CFR 50.72(b)(2)(iv)(A). Therefore, the licensee is retracting this event.

The NRC Resident Inspector will be notified.

The following individuals have been notified of this update:
Reg 2 RDO Barr NRR EO Boger IRO Giitter DOE Stambaugh EPA(NRC) Crews FEMA Stinederf
USDA Conley NMSS Holahan HHS Cruz HP Pederson SCDHEC Jesse


General Information or Other
Event Number: 37603
Rep Org: WA DIVISION OF RADIATION PROTECTION
Licensee: MDS PHARMA SERVICES, INC.
Region: 4
City: BOTHELL   State: WA
County:
License #: WN-L0106-1
Agreement: Y
Docket:
NRC Notified By: TERRY FRAZEE
HQ OPS Officer: FANGIE JONES
Notification Date: 12/15/2000
Notification Time: 15:37 [ET]
Event Date: 10/14/2000
Event Time: 00:00 [PST]
Last Update Date: 12/15/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
JOHN GREEVES (NMSS)
Event Text
AGREEMENT STATE REPORT

The following is taken from an e-mail report:

This is notification of an event in Washington state as identified by the WA Department of Health, Division of Radiation Protection during a routine license inspection.

STATUS: new/closed

Licensee: MDS Pharma Services, Inc.
City and state: Bothell, WA
License number: WN-L0106-1
Type of license: Research lab

Date of event: October 14, 1999
Location of Event: Bothell, WA
ABSTRACT: (where, when, how, why; cause, contributing factors, corrective actions, consequences, DOH onsite investigation; media attention) On October 14, 1999, a Yellow II packaged from Amersham Corporation, Arlington Heights, IL, was delivered by Federal Express to the licensee. The package contained 5 millicuries of H-3 and 10 microcuries of I-125 in sealed vials. Laboratory personnel measured 10 mR/hr on the package surface with nothing detectable at a meter thus verifying the Yellow II label. The package appeared in good shape and personnel unpacked the contents and determined that the exterior of the vials and inner packaging were free of contamination. However, upon surveying the empty packaging, the outside corner of the outer package was determined to be contaminated. 12,000 counts per minute of removable contamination were noted using a sodium iodide detector. No reading was detected on the wipe using a pancake probe leading the licensee to conclude the source of the activity was most likely I-125. The licensee immediately called ChemTrec which in turn notified shipper. Amersham called the licensee and informed the RSO that Amersham would take care of any additional notifications including the carrier. The licensee documented the event and instituted additional handling procedures for all future receipts.

On December 5, 2000, during a routine license inspection by the WA Department of Health, the inspectors noted the incident report and that the licensee had failed to notify the department as required (the department estimated the removable contamination to be 120,000 DPM and thus required to be reported). The licensee was cited for failing to notify the department. This report is being made to complete the record.

What is the notification or reporting criteria involved? WAC 246-221-160 Procedures for picking up, receiving, and opening packages.


Power Reactor
Event Number: 39299
Facility: WATERFORD
Region: 4     State: LA
Unit: [3] [] []
RX Type: [3] CE
NRC Notified By: GREGORY SCOTT
HQ OPS Officer: RICH LAURA
Notification Date: 10/17/2002
Notification Time: 15:50 [ET]
Event Date: 10/14/2000
Event Time: 23:00 [CDT]
Last Update Date: 10/17/2002
Emergency Class: NON EMERGENCY
10 CFR Section:
50.73(a)(1) - INVALID SPECIF SYSTEM ACTUATION
Person (Organization):
GREG PICK (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N N 0 Hot Standby 0 Hot Standby
Event Text
INADVERTENT EFW ACTUATION ON 10/14/2000

"Per 10CFR50.73(a), Entergy is providing a verbal notification of an inadvertent actuation of the emergency feedwater (EFW) system at Waterford 3, which occurred on October 14, 2000. This event was initially determined to be not reportable, based on the reasoning that the actuation of the emergency feedwater components were initiated from the Diverse Emergency Feedwater System (DEFAS), and not from an Emergency Feedwater Actuation System (ESFAS) actuation. However, during a technical specification audit in August of 2002, questions were raised regarding the validity of this reportability determination and a condition report was initiated. A subsequent review by licensing completed on August 21, 2002 determined that the event should have been reported per the then existing 10CFR50.72 (b)(3)(iv) requirement as a 4-hour notification and reported as a follow-up LER notification per 10CFR50.73(a). The current applicable reporting criteria do not require immediate notification, however an LER or verbal notification is required per 10CFR50.73(a). Accordingly, this report is provided as a verbal notification per 10CFR50.73(a), Reportable events, which states, in part, in the case of an invalid actuation reported under 50.73(a)(2)(iv), the licensee may, at its option, provide a telephone notification to the NRC Operation Center within 60 days after the discovery of the event instead of submitting a written LER. This actuation was invalid, as described further below.

"On October 14, 2000, the plant was in mode 3 in preparation for refueling outage 10, when an inadvertent actuation of emergency feedwater components occurred. This event occurred during the performance of procedure OP-904-017, Anticipated Transient System Check. While performing section 7.2, Testing of Diverse Emergency Feedwater System (DEFAS), step 7.2.12 (to replace the Diverse Emergency Feedwater Actuation System selector switch to disable) was inadvertently missed. This caused the emergency feedwater components to move to their safety positions when the DEFAS test switch was restored to its normal position. The two motor driven emergency feedwater pumps and the steam driven emergency feedwater pump started. The emergency feedwater isolation valves opened, but the emergency feedwater control valves did not open, as per design, due to adequate steam generator water levels. Accordingly, this event did not result in emergency feedwater flow or emergency feedwater injection into the steam generators. The operator immediately secured the EFW pumps and closed the EFW isolation valves.

"NUREG 1022, revision 2, Event Reporting Guidelines 10CFR50.72 and 50.73 provides guidance for determining if an actuation is invalid. The NUREG states, in part, that invalid actuations include actuations that are not the result of valid signals and are not intentional manual actuations. Valid signals are those signals that are initiated in response to actual plant conditions or parameters satisfying the requirements for initiation of the safety function of the system. This report documents an actuation that was not the result of a valid signal and was not an intentional manual actuation, For these reasons, this event constitutes an invalid actuation."

The NRC resident inspector was notified.