Event Notification Report for September 26, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/25/2000 - 09/26/2000

EVENT NUMBERS
3738237383373783737937380

Power Reactor
Event Number: 37382
Facility: HATCH
Region: 2     State: GA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: ED BURKETT
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/26/2000
Notification Time: 18:45 [ET]
Event Date: 09/26/2000
Event Time: 16:20 [EDT]
Last Update Date: 09/26/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
CHARLES R. OGLE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 95 Power Operation 95 Power Operation
Event Text
EXCESS FLOW CHECK VALVE FOR "A" RECIRCULATION PUMP # 2 SEAL PRESSURE SIGNAL FAILED TO SEAT OFF WHEN TESTED.

Excess flow check valve 1B31F003A failed to check (seat off) when tested per S7SV-SUV-004-1S. This excess flow check valve provides isolation for the "A" Recirculation Pump # 2 seal pressure signal. The excess flow check valve will be isolated per Technical Specification 3.6.1.3.C (Primary Containment Isolation Valve). Technical Specification 3.6.1.3.C states that ,if the valve cannot be isolated, the plant must be in Mode 3 (Hot Shutdown) within 12 hours. The licensee stated that the valve will be isolated before the TS time limit runs out.

The NRC Resident Inspector will be notified by the licensee of this event.


Fuel Cycle Facility
Event Number: 37383
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: JIM McCLEERY
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/26/2000
Notification Time: 20:40 [ET]
Event Date: 09/26/2000
Event Time: 17:30 [EDT]
Last Update Date: 10/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
BRENT CLAYTON (R3)
JOHN HICKEY (NMSS)
FRANK CONGEL (IRO)
Event Text
4-HOUR NRC BULLETIN 91-01 REPORT INVOLVING THE X-705, DECON FACILITY, COMPLEXING HANDTABLE DUCTWORK

At 1730 during a review of Nuclear Criticality Safety Approval (NCSA) Corrective Action Plan (CAP) with NCS it was noted that the X-705 Complexing Handtable was not covered by an active NCSA. NCSA 705_014A00 had been cancelled and the PORC approved 705_014A01 was not activated. Based on security sweep data completed by Applied Nuclear Technology (ANT) personnel it can be conservatively estimated that greater than 15 grams of U-235 exist in the duct work associated with the handtable. TSR 3.11.2 Requires a NCSA when operations involve uranium enriched to 1.0% or higher U-235 and 15 grams or more U-235.

The complexing handtable has not been in operation since NRC transition on 03/03/97 and remains out of service. Upon notification of this issue the Plant Staff Superintendent office directed the facility management to enter an anomalous condition. This is reportable under UE2-RA-RE1030 (Event Report Criteria) 3.C.1 as a 4 hour NRC Bulletin 91-01 event.

SAFETY SIGNIFICANCE OF EVENT:

The safety significance of this event is very low. No operation had taken place on the complexing handtable since transition on 03/03/97. The small amount of hold up may be greater than 15 grams of U-235, however, the available data for the remainder of the handtable operation shows reading at or near background levels.

POTENTIAL CRITICALITY PATHWAYS INVOLVED (BRIEF SCENARIO OF HOW CRITICALITY , ETC.):

Since the handtable and associated piping are favorable geometry for any enrichment, material would have to accumulate in the ductwork or pile up to achieve a critical configuration. The operation is not currently being performed and the ductwork is not connected to any system, therefore, a criticality does not appear credible.

CONTROLLED PARAMETERS (MASS, MODERATION, GEOMETRY, CONCENTRATION, ETC.):

The controlled parameter is geometry. The approved, but not implemented NCSA establishes two controls based on geometry.

ESTIMATED AMOUNT, ENRICHMENT, FORM OF LICENSED MATERIAL (INCLUDE PROCESS LIMIT AND % WORST CASE OF CRITICAL MASS):

The amount of U-235 is not more than 25 grams. Enrichment is not known, but could be as high as 100%. The form of material is either uranyl fluoride or uranyl nitrate.

NUCLEAR CRITICALITY SAFETY CONTROL OR CONTROL SYSTEMS AND DESCRIPTION OF THE FAILURES OR DEFICIENCIES

The only deficiency is that the ductwork for the handtable potentially contains more than 15 grams U-235 without an active NCSA to establish the necessary controls to ensure double contingency.

CORRECTIVE ACTIONS TO RESTORE SAFETY SYSTEM AND WHEN EACH WAS IMPLEMENTED:

Anomalous condition remains in effect until evaluations and testing are completed.

The NRC Resident Inspector was notified of this event by the certificate holder.


* * * UPDATE ON 10/01/00 @ 1010 BY SPAETH TO GOULD * * *

Non-Destructive Assay (NDA) analysis completed on 9/28/00 indicates less than 15 grams of U-235 are present in the X-705 complexing handtable and associated ductwork. The total U-235 identified in the and associated ductwork is less than 6 grams including measurement uncertainties. An NCSA is, therefore, not required for this equipment per TSR 3.11.2.

The NRC Resident Inspector was notified. The DOE Representative will be notified.

The Reg 3 RDO(Clayton) and NMSS(Hickey) were notified.

HOO Note: Portsmouth does not retract 91-01 Bulletins reports.


Power Reactor
Event Number: 37378
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: THOMAS MARSHALL
HQ OPS Officer: STEVE SANDIN
Notification Date: 09/26/2000
Notification Time: 01:23 [ET]
Event Date: 09/26/2000
Event Time: 00:43 [EDT]
Last Update Date: 09/26/2000
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED
Person (Organization):
THOMAS DECKER (R2)
BILL BATEMAN (NRR)
JOSEPH GIITTER (IRO)
CANUPP (FEMA)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
UNIT 1 MET THE CONDITIONS FOR AN UNUSUAL EVENT BASED ON RCS LEAKAGE > 25 GPM WHILE IN MODE 4.

"While placing the '1A' RHR Pump in service for shutdown cooling, the Unit experienced an RCS leak of approximately 45 gpm. It is believed that the cause of the leak is a relief valve that lifted and failed to reseat. The leak was isolated from the RCS when the RHR suction valves from the RCS (1-FCV-74-1 and 1-FCV-74-2) were closed. The leak lasted approximately 10 minutes.

"According to the Plant's Radiological Emergency Plan, the conditions for a Notification of Unusual Event (NOUE) were met, but before it could be declared the leak was isolated, so an NOUE was not declared but will be reported."

The RCS which leak occurred at 0002EDT was terminated at 0012EDT (10 minutes). Operators estimated the leakage at 45 gpm based on the change in PRT (pressurizer relief tank) level. The two relief valves involved are 1-VLV-63-626 and 1-VLV-63-627 with setpoints of approximately 600 psig. RCS pressure was 345 psig when the RHR suction valves were opened. The RHR pumps develop approximately 180 psig which combined with the 345 psig RCS pressure (inlet) indicated about 525 psig RHR discharge pressure in the control room. Both trains of RHR have been declared inoperable pending identification and correction of the problem. Decay heat is current being removed by the main condenser through the steam dumps using both motor-driven auxiliary feedwater pumps. The licensee has no plans for a press release at this time and did inform the NRC resident inspector.


Power Reactor
Event Number: 37379
Facility: SAN ONOFRE
Region: 4     State: CA
Unit: [] [2] [3]
RX Type: [1] W-3-LP,[2] CE,[3] CE
NRC Notified By: CLAY WILLIAMS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/26/2000
Notification Time: 16:35 [ET]
Event Date: 09/26/2000
Event Time: 13:00 [PDT]
Last Update Date: 09/26/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
CHUCK CAIN (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION MADE TO THE CALIFORNIA DEPARTMENT OF ENVIRONMENTAL HEALTH AND THE OFFICE OF EMERGENCY SERVICES FOR A SODIUM HYPOCHLORIDE TANK LEAK.

On September 26, 2000, at about 0816 PDT, control room personnel were notified of a small leak from Unit 2 sodium hypochloride tank. The leak was in the tank discharge line upstream of the outlet isolation valve. At about 1020 PDT, site personnel completed installation of a soft patch to terminate the leak (SCE is planning to implement a more permanent repair after the tank contents have been offloaded). All of the estimated 300 gallons that leaked from the tank was contained within a tank sump and was not released to the environment.

The NRC Resident Inspector has been informed of this event by the licensee.


General Information or Other
Event Number: 37380
Rep Org: CALIFORNIA RADIATION CONTROL PRGM
Licensee: LAW ENGR. ENVIRONMENTAL SERVICE, KY
Region: 4
City: SACARAMENTO   State: CA
County:
License #: KY 201257-51
Agreement: Y
Docket:
NRC Notified By: BOB FUNDERBURG
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/26/2000
Notification Time: 18:10 [ET]
Event Date: 09/26/2000
Event Time: 06:00 [PDT]
Last Update Date: 09/26/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
JOHN HICKEY (NMSS)
Event Text
TROXLER MOISTURE DENSITY GAUGE STOLEN FROM THE BACK OF A PICKUP TRUCK.

An employee of Law Engineering Environmental Service of Kentucky had reciprocity with the state of Nevada. After the employee had completed his work in Las Vegas, NV he decided to take the long way home. He spent the night at the Holiday Inn in downtown Sacramento, CA. In the morning the person discovered that the chain had been cut to the Troxler Moisture Density gauge, Model #3411-B S/N 12599. The Sacramento Police Department was notified of the theft of the gauge. An ad will be placed in the Sacramento Bee newspaper with a $1,000 reward for the return of the gauge. The Radiation Safety Officer for Law Engineering Environmental Service was notified of this incident.