373813737437375373763737737420

Other Nuclear Material
Event Number: 37381
Rep Org: PHILLIP MORRIS, USA
Licensee: PHILLIP MORRIS, USA
Region: 2
City: RICHMOND   State: VA
County:
License #: 45-00385-06
Agreement: N
Docket:
NRC Notified By: CHUCK STIFF
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/26/2000
Notification Time: 18:28 [ET]
Event Date: 09/25/2000
Event Time: 17:00 [EDT]
Last Update Date: 09/26/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2)(ii) - EQUIP DISABLED/FAILS
Person (Organization):
CHARLES R. OGLE (R2)
JOHN HICKEY (NMSS)
Event Text
ACCURAY MICRO 10 GAUGE LEAD FUSIBLE LINK MELTED AND CAUSED THE SHUTTER OF THE GAUGE TO REMAIN OPEN.

24 HOUR NOTIFICATION

An Accuray Micro 10 gauge, containing a 25 millicurie Sr-90 sealed source, fusible lead link melted, preventing the gauge shutter from closing. A warning light associated with Accuray Micro 10 gauge warned plant personnel that the shutter to the gauge was still open. Nobody was exposed. The Accuray Micro 10 gauge registration number is NR-109-D-125-B. The shutter of the gauge was closed, placed in a lead pig and stored in a lead safe.


General Information or Other
Event Number: 37374
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: ARIAF & KEZAR INC
Region: 4
City: SAN ANTONIO   State: TX
County:
License #: L04964-001
Agreement: Y
Docket:
NRC Notified By: OGDEN (FAX)
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 09/25/2000
Notification Time: 09:14 [ET]
Event Date: 09/25/2000
Event Time: 07:30 [CDT]
Last Update Date: 09/25/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHUCK CAIN (R4)
DON COOL (NMSS)
Event Text
TEXAS DEPARTMENT OF HEALTH WAS NOTIFIED BY ONE OF THEIR LICENSEES OF A STOLEN TROXLER GAUGE IN BROWNSVILLE, TEXAS

A Troxler Model 3430, Serial No. 31532, sources: 8 millicurie Cs-137, Serial No. 750-6340; and 40 millicurie Am-241 /Be, Serial No. 47-28154 was apparently stolen from the back of a company truck at an overnight lodging in Brownsville Texas. The operator/driver discovered the theft between 7:30 a.m. and 8:00 a.m. this morning. The security chains in the bed of the truck had been cut. The gauge and the operators tool box were stolen. A police report has been filed with the Brownsville Police Department. The gauge was to be used at a temporary jobsite today. The owner of the stolen gauge is a Texas Licensee, L04964-001. The licensee is considering offering a reward for return of the gauge.


Power Reactor
Event Number: 37375
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: HOWARD
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 09/25/2000
Notification Time: 11:18 [ET]
Event Date: 09/25/2000
Event Time: 10:33 [EDT]
Last Update Date: 09/25/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
THOMAS DECKER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 78 Power Operation 0 Hot Standby
Event Text
REACTOR TRIP FROM 78% POWER DUE TO A LOW STEAM GENERATOR LEVEL

The event was initiated at 1030 EDT when the "1A" main feedwater pump tripped. An automatic runback [from 100%] to 75% turbine power occurred, however, the "1B" main feedwater pump did not automatically speedup to full load as designed. An attempt to manually load the "1B" main feedwater pump was ineffective and a trip occurred as a result of a low steam generator level. All rods fully inserted, no ECCS initiated and no safety valves lifted. They are investigating the cause of this event.

The NRC Resident Inspector was notified.


Power Reactor
Event Number: 37376
Facility: CALVERT CLIFFS
Region: 1     State: MD
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: O'MEARA
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/25/2000
Notification Time: 12:47 [ET]
Event Date: 09/25/2000
Event Time: 08:15 [EDT]
Last Update Date: 09/25/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN KINNEMAN (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
LICENSEE TECHNICAL REQUIREMENT 24 HOUR REPORT

The licensee, in accordance with their Technical Review (Requirement) Manual 15.7.5.c, reported that one of their diesel fire pumps and one pretreatment water storage tank (# 12) was removed from service for planned maintenance. The diesel fire pump was taken out of service to install a flange to isolate the pretreatment water storage tank for maintenance. The pump being out-of-service and having one of two sources of water out-of-service prompted the 24 hour report.

The NRC Resident Inspector was notified of this event by the licensee.

See similar Event # 37367 reported on 09/22/00.


Power Reactor
Event Number: 37377
Facility: HATCH
Region: 2     State: GA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: UNDERWOOD
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/25/2000
Notification Time: 14:30 [ET]
Event Date: 09/25/2000
Event Time: 14:00 [EDT]
Last Update Date: 09/25/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
THOMAS DECKER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 95 Power Operation 95 Power Operation
Event Text
Unescorted access granted inappropriately. Immediate compensatory measures taken upon discovery.

Refer to the HOO Log for additional details.


Other Nuclear Material
Event Number: 37420
Rep Org: MIDAMERICA PETERBUILT
Licensee: MIDAMERICA PETERBUILT
Region: 3
City: O'FALLON   State: MO
County: ST. CHARLES
License #:
Agreement: N
Docket:
NRC Notified By: LONNIE EKEREN
HQ OPS Officer: FANGIE JONES
Notification Date: 10/10/2000
Notification Time: 15:17 [ET]
Event Date: 09/25/2000
Event Time: 00:00 [CDT]
Last Update Date: 10/10/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
MONTE PHILLIPS (R3)
Event Text
LOST STAT ATTACK GUN WITH POLONIUM-210 SOURCE

The company lost an anti-static device used in painting vehicles. The device is a Stat Attack Gun, containing a nominal 10 mCi Po-210 sealed source. The device is a model # PBM1002H, serial #9807KB. The device is believed lost in the trash after an extensive search of the facility.