Event Number: 37295
Rep Org: R.D. ZANDE & ASSOCIATES
Licensee: R.D. ZANDE & ASSOCIATES
Region: 2
City: KYSER   State: WV
County: GRANT
License #:
Agreement: N
Docket:
NRC Notified By: JOE STOCK
HQ OPS Officer: FANGIE JONES
Notification Date: 09/06/2000
Notification Time: 15:45 [ET]
Event Date: 09/06/2000
Event Time: 00:00 [EDT]
Last Update Date: 09/06/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MARK LESSER (R2)
GARY SHEAR (R3)
E. WILLIAM BRACH (NMSS)
Event Text
TROXLER GAUGE DAMAGED BY TRUCK RUNNING OVER IT

R.D. Zande and Associates (of Columbus, OH) was conducting a back scatter test on asphalt on State Route 220 in Kyser, WV when an asphalt truck backed over it. The gauge is a Troxler Model 3411 with a cesium source. The case was damaged , case cracked, and the extension rods were damaged. The source was extended at the time and not believed to be damaged. The source was recovered into the shielded position. The gauge will be transported to Cline Technical Services in Amanda, Ohio, will be wipe tested there and final disposition of the gauge will be determined.

The company has contacted NRC Region 3 (John Madera and Sam Mulea).


Power Reactor
Event Number: 37296
Facility: GRAND GULF
Region: 4     State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ERNEST MATHES
HQ OPS Officer: FANGIE JONES
Notification Date: 09/06/2000
Notification Time: 18:38 [ET]
Event Date: 09/06/2000
Event Time: 16:21 [CDT]
Last Update Date: 09/06/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
WILLIAM JOHNSON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
DURING SURVEILLANCE AN AUTOMATIC ISOLATION SIGNAL WAS GENERATED DUE TO MISSED SWITCH POSITIONING

"Reactor Core Isolation Cooling (RCIC) system isolated during performance of Annual Leak Detection surveillance (06-IC-A-1003-02). Investigation revealed leak detection switches not in bypass during test. System responded as designed. ES1-F064 (Mn Steam isolation) and trip Throttle valve closed. System restored to standby."

The licensee determined there was a missed step in the surveillance procedure.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 37293
Facility: SOUTH TEXAS
Region: 4     State: TX
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: W. MOOKHOEK
HQ OPS Officer: FANGIE JONES
Notification Date: 09/06/2000
Notification Time: 12:13 [ET]
Event Date: 09/06/2000
Event Time: 08:45 [CDT]
Last Update Date: 09/06/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
WILLIAM JOHNSON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
VITAL BUS SUPPLY BREAKER FOUND TO HAVE IMPROPER TRIP SETTING AFFECTING OPERABILITY

"On August 29, 2000, at 0038 CDT, Unit 2 experienced a loss of power to Class 1 E 480v motor control center (MCC) E2C1. The power loss resulted in a loss of normal letdown in the Chemical Volume Control System and loss of other safety related loads. The MCC was re-energized at 0108 CDT and plant systems were restored to normal.

"An investigation found the long time overload settings for the feeder breaker to MCC E2C1 to be one-half of the required values. The condition had existed since October 23, 1999, when the breaker was placed in service. At 0845 on September 6, 2000, this condition was determined to be reportable after completion of an engineering evaluation. The engineering evaluation determined that the breaker had a high potential for opening under accident conditions because of the improper settings. The condition was corrected on August 29, 2000, at 1806 CDT. The corresponding breakers in the other ESF trains and in Unit 1 were found to have the correct settings.

"Some safety related equipment powered from the MCC was determined to have been inoperable since October 23, 1999, because opening of the breaker would have interrupted the equipment's ability to perform its
design function. The duration of inoperability exceeded the Technical Specification allowed outage time for some systems, which include:
- 1 of 3 trains of Essential Chilled Water (TS 3/4.7.14): inoperable essential chilled water pump 21C
- 1 of 3 trains of Control Room Envelope HVAC (TS 3/4.7.7): inoperable makeup fan 21C
- 1 of 3 Standby Diesel Generators (TS 3/4.8.1): inoperable emergency supply fan 21C (support system for SDG 23)

"This condition is reportable under 10CFR50.73(a)(2)(i)(B) and notification is required within 24 hours by Section 2G of the Unit 2 Operating License (NPF-80)"

The licensee notified the NRC Resident Inspector.