Event Notification Report for September 04, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/03/2000 - 09/04/2000

EVENT NUMBERS
372883732337287

Power Reactor
Event Number: 37288
Facility: HATCH
Region: 2     State: GA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: ANDY DISMUKE
HQ OPS Officer: FANGIE JONES
Notification Date: 09/04/2000
Notification Time: 15:30 [ET]
Event Date: 09/04/2000
Event Time: 14:16 [EDT]
Last Update Date: 09/04/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
CAUDLE JULIAN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
INADVERTENT DEENERGIZATION OF THE '2A' RPS MG SET CAUSED GROUP 2 AND 5 ISOLATIONS

Plant personnel inadvertently tripped breaker to the '2A' reactor protection system motor generator (RPS MG) set resulting in de-energization of the '2A' RPS bus. This resulted in the closure of the inboard Group 2 containment isolation valves, the inboard Group 5 reactor water cleanup valve, inboard reactor water sample valve, the control room ventilation swapped to the pressurization mode of operation, and a half scram in the 'A' RPS channel. All actuations have been reset and the '2A' RPS bus is energized from the alternate supply while an investigation is being conducted.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 37323
Facility: WOLF CREEK
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DALE BERRY
HQ OPS Officer: JOHN MacKINNON
Notification Date: 09/14/2000
Notification Time: 18:47 [ET]
Event Date: 09/04/2000
Event Time: 14:24 [CDT]
Last Update Date: 09/14/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
GARY SANBORN (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Hot Standby 0 Hot Standby
Event Text
FEEDWATER ISOLATION

During Post Trip review, it was discovered that a second feedwater isolation signal that occurred was not reported. This second feedwater isolation signal occurred following the reactor trip, see event # 37287, previously reported on 09/04/00. This notification is to report the additional feedwater isolation signal that occurred September 4, 2000 at 1424 hours.

The feedwater isolation signal occurred when the steam dump valves that were being used to control reactor coolant system temperature popped open . This caused "B" steam generator water level to swell above the feedwater isolation signal setpoint of 78%.

All equipment operated as required. The feedwater isolation valves closed due to the feedwater isolation signal. These valves were the only equipment not already in the feedwater isolation system required position.

The effect of the feedwater isolation signal on the plant was minimal. The feedwater isolation valves were reopened at 1514 hours to allow feeding steam generators with the Motor Driven Startup Feedwater Pump.

The plant is currently in Mode 1 at 100% power.

The NRC Resident Inspector will notified of this event by the licensee.


Power Reactor
Event Number: 37287
Facility: WOLF CREEK
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: JIM GILMORE
HQ OPS Officer: FANGIE JONES
Notification Date: 09/04/2000
Notification Time: 15:00 [ET]
Event Date: 09/04/2000
Event Time: 11:32 [CDT]
Last Update Date: 09/04/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION 50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
DAVE LOVELESS (R4)
STUART RICHARDS (NRR)
VICTOR DRICKS (PAO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Standby
Event Text
REACTOR TRIP DUE TO FIRE IN UNIT AUXILIARY TRANSFORMER

At about 1132 CDT a fire was reported in the unit auxiliary transformer, alarms were received in the control room with a unit trip, all rods fully inserted. The on-site fire brigade and the off-site fire department were called to respond. The fire was extinguished by installed fire suppression equipment and declared out at 1143 CDT. The fire is being investigated by fire protection personnel. The off-site fire department was released.

The plant is stable in Hot Standby at normal temperature and pressure. Heat removal is via the main condensers with steam generator level being maintained by auxiliary feedwater.

The auxiliary feedwater system, both turbine and motor driven, started automatically on low steam generator level as expected with this event. All safety equipment performed as designed.

Concurrent with the reactor trip, the 'C' and 'D' reactor coolant pumps tripped along with other loads due to one (PA02) of the two non-vital busses not automatically transferring as expected to off-site power. The bus is presently energized by off-site power and the 'D' reactor coolant pump was restarted. The actual cause of the problem is being investigating.

One of the reactor coolant system power operated relief valve opened and closed one time due the transient of the 'D' reactor coolant pump trip and subsequent loss of pressurizer spray.

The licensee notified the NRC Resident Inspector.