Event Notification Report for August 25, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/24/2000 - 08/25/2000
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37259
Facility: MCGUIRE
Region: 2 State: NC
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DON BRENTON
HQ OPS Officer: FANGIE JONES
Region: 2 State: NC
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DON BRENTON
HQ OPS Officer: FANGIE JONES
Notification Date: 08/25/2000
Notification Time: 18:16 [ET]
Event Date: 08/25/2000
Event Time: 17:30 [EDT]
Last Update Date: 09/05/2000
Notification Time: 18:16 [ET]
Event Date: 08/25/2000
Event Time: 17:30 [EDT]
Last Update Date: 09/05/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
ROBERT HAAG (R2)
KEN BARR (IAT)
JOHN DAVIDSON (IAT)
ROBERT HAAG (R2)
KEN BARR (IAT)
JOHN DAVIDSON (IAT)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
PHYSICAL SECURITY REPORT
Potential tampering event, immediate compensatory measures taken upon discovery. Contact the NRC Operations Center for additional details.
The licensee intends to notify the NRC Resident Inspector and the R2 Security Inspector (Dave Thompson).
* * * RETRACTED AT 1206 EDT ON 9/5/00 BY VERIDA BELLAMY TO FANGIE JONES * * *
After investigation it was determined that during a planned work activity workers manipulated the wrong component and it was not tampering. Therefore, this event notification is retracted. There will be no written followup to this event.
The licensee notified the NRC Resident Inspector. The NRC Operations Center notified the R2DO (Caudle Julian) and IAT (John Davidson).
Potential tampering event, immediate compensatory measures taken upon discovery. Contact the NRC Operations Center for additional details.
The licensee intends to notify the NRC Resident Inspector and the R2 Security Inspector (Dave Thompson).
* * * RETRACTED AT 1206 EDT ON 9/5/00 BY VERIDA BELLAMY TO FANGIE JONES * * *
After investigation it was determined that during a planned work activity workers manipulated the wrong component and it was not tampering. Therefore, this event notification is retracted. There will be no written followup to this event.
The licensee notified the NRC Resident Inspector. The NRC Operations Center notified the R2DO (Caudle Julian) and IAT (John Davidson).
Transportation Event
Event Number: 37256
Rep Org: NORTHWOOD PANELBOARD
Licensee: NORTHWOOD PANELBOARD
Region: 3
City: MAUSTON State: WI
County: JUNEAU
License #: 22-20033-01
Agreement: N
Docket:
NRC Notified By: ROBERT CLAYPOOL
HQ OPS Officer: JOHN MacKINNON
Licensee: NORTHWOOD PANELBOARD
Region: 3
City: MAUSTON State: WI
County: JUNEAU
License #: 22-20033-01
Agreement: N
Docket:
NRC Notified By: ROBERT CLAYPOOL
HQ OPS Officer: JOHN MacKINNON
Notification Date: 08/25/2000
Notification Time: 11:05 [ET]
Event Date: 08/25/2000
Event Time: 05:00 [CDT]
Last Update Date: 08/25/2000
Notification Time: 11:05 [ET]
Event Date: 08/25/2000
Event Time: 05:00 [CDT]
Last Update Date: 08/25/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
PATRICK HILAND (R3)
BRIAN SMITH (NMSS)
RADDY, NRC (DOT) (NRC)
STAMBAUGH (DOE)
FRANK CONGEL (IRO)
PATRICK HILAND (R3)
BRIAN SMITH (NMSS)
RADDY, NRC (DOT) (NRC)
STAMBAUGH (DOE)
FRANK CONGEL (IRO)
TRACTOR TRAILER TRUCK CARRYING 8 SEALED SOURCES OVERTURNED ON HIGHWAY.
Licensee, Northwood Panelboard, located in Solway, MN reported the following event.
Northwood Panelboard was shipping 8 sealed source holders, each containing 100 mCi of Cs-137, in two boxes to Radiation Technology located in Odessa, Texas. Vitran Express, the shipping company, informed Northwood Panelboard that the shipping tractor trailer had been involved in an accident on a major highway outside of Mauston, Wi. The tractor trailer is lying on its side blocking traffic. Four sealed source holders are contained in each padlocked crate. The crates are type A packages with a transportation index of 0.1. Wisconsin HAZMAT team has been dispatched to the seen of the accident. NRC Region 3 (Darrel Wiedeman & Robert Gattone) were notified of this event by the licensee.
Licensee, Northwood Panelboard, located in Solway, MN reported the following event.
Northwood Panelboard was shipping 8 sealed source holders, each containing 100 mCi of Cs-137, in two boxes to Radiation Technology located in Odessa, Texas. Vitran Express, the shipping company, informed Northwood Panelboard that the shipping tractor trailer had been involved in an accident on a major highway outside of Mauston, Wi. The tractor trailer is lying on its side blocking traffic. Four sealed source holders are contained in each padlocked crate. The crates are type A packages with a transportation index of 0.1. Wisconsin HAZMAT team has been dispatched to the seen of the accident. NRC Region 3 (Darrel Wiedeman & Robert Gattone) were notified of this event by the licensee.
Other Nuclear Material
Event Number: 37257
Rep Org: CROW BUTTE RESOURCES
Licensee: CROW BUTTE RESOURCES
Region: 4
City: CRAWFORD State: NE
County:
License #: SUA 1534
Agreement: Y
Docket:
NRC Notified By: MIKE GRIFFIN
HQ OPS Officer: FANGIE JONES
Licensee: CROW BUTTE RESOURCES
Region: 4
City: CRAWFORD State: NE
County:
License #: SUA 1534
Agreement: Y
Docket:
NRC Notified By: MIKE GRIFFIN
HQ OPS Officer: FANGIE JONES
Notification Date: 08/25/2000
Notification Time: 12:31 [ET]
Event Date: 08/25/2000
Event Time: 00:00 [CDT]
Last Update Date: 08/25/2000
Notification Time: 12:31 [ET]
Event Date: 08/25/2000
Event Time: 00:00 [CDT]
Last Update Date: 08/25/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
LARRY YANDELL (R4)
SCOTT MOORE (NMSS)
LARRY YANDELL (R4)
SCOTT MOORE (NMSS)
LEAK IN PRIMARY LINER
The company had high conductivity on the monitor for primary liner leak detection for a settling pond for ion exchanger backwash. The pond mainly contains brine with some residual uranium. An investigation discovered a previously repaired tear had reopened, the tear is located about 3 feet above the water level. It is thought that wind action formed waves were the source of the water. There is no indication of leakage past the secondary liner. The company plans to continue inspecting the primary liner and will lower water level further to make repairs.
The company contacted the Nebraska Department of Environmental Quality.
The company had high conductivity on the monitor for primary liner leak detection for a settling pond for ion exchanger backwash. The pond mainly contains brine with some residual uranium. An investigation discovered a previously repaired tear had reopened, the tear is located about 3 feet above the water level. It is thought that wind action formed waves were the source of the water. There is no indication of leakage past the secondary liner. The company plans to continue inspecting the primary liner and will lower water level further to make repairs.
The company contacted the Nebraska Department of Environmental Quality.