Event Notification Report for August 24, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/23/2000 - 08/24/2000

EVENT NUMBERS
372533725437280

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37253
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: SQUIRES
HQ OPS Officer: JOHN MacKINNON
Notification Date: 08/24/2000
Notification Time: 05:27 [ET]
Event Date: 08/24/2000
Event Time: 04:35 [EDT]
Last Update Date: 09/06/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(vi) - INTERNAL THREAT
Person (Organization):
CHRISTOPHER CAHILL (R1)
CHARLES MILLER (IRO)
TAD MARSH (NRR)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 53 Power Operation
Event Text
SMOKE AND SMALL FLAMES FROM "B" REACTOR FEED PUMP (RFP) OUTBOARD BEARING. FIRE LESS THAN 15 MINUTES.

Control room plant received a high bearing temperature alarm from the "B" RFP. Plant personnel were dispatched to investigate. Smoke and small flames were seen around the outboard bearing of "B" RFP. Onsite fire brigade was dispatched to extinguish the fire. Fire brigade was unsuccessful in extinguishing the fire using carbon dioxide. Fire was extinguished using a fire hose. No other electrical systems were wetted by the fire hose. Reactor power was reduced from 100% to approximately 53% power at which time the "B" RFP was taken out service. A reflash fire watch is stationed at the "B" RFP. Lagging has been removed from the RFP and the lagging where the smoke and fire issued from is oil soaked. Investigation of fire is in progress. Unnecessary personnel were evacuated from the area of the fire. "B" RFP is located in the Turbine Building lower level (252'). All Emergency Core Cooling Systems are fully operable except for HPCI (see event # 37252). Offsite electrical grid is stable. No offsite site help was needed. Fire lasted from 0435 ET until 0449 ET.

The NRC Resident Inspector was notified of this event by the licensee.

* * * RETRACTED AT 1348 EDT ON 9/6/00 BY BOB STEIGERWALD TO FANGIE JONES * * *

"This notification retracts an earlier report made on 08/24/00, at 05:27 (EDT), per 10CFR50.72(b)(1)(vi). A fire was reported at the outboard bearing of the 'B' Reactor Feed Pump. The fire was minor in nature, limited to the 'B' feed pump room, extinguished within 15 minutes of discovery, and did not hamper the ability of personnel to perform safety-related activities affecting plant safety. Reactor power was reduced and the 'B' feed pump was removed from service. Therefore, this event notification is being retracted."

The licensee notified the NRC Resident Inspector. The R1DO (Anthony Dimitriadis) was notified.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37254
Facility: SALEM
Region: 1     State: NJ
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: VAN FORD
HQ OPS Officer: FANGIE JONES
Notification Date: 08/24/2000
Notification Time: 21:22 [ET]
Event Date: 08/24/2000
Event Time: 20:30 [EDT]
Last Update Date: 09/15/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
CHRISTOPHER CAHILL (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
CONTROL ROOM VENTILATION NOT ALIGNED PROPERLY FOR TOXIC CHEMICAL DELIVERY

The licensee reported that they were potentially outside of design license basis for the receipt of hazardous/toxic chemicals, specifically ammonium hydroxide 15 % by weight. A delivery truck arrived at the site and was admitted to the protected area before the proper alignment was made for receipt. The control room was contacted, but the alignment of control room ventilation was not completed prior to admitting the truck. The control room ventilation has been placed in full recirculation for chemical receipt at this time. The total time ventilation was not properly aligned is not available at this time.

The licensee intends to notify the NRC Resident Inspector.

* * * UPDATE AT 2345 EDT ON 8/24/00 BY VAN FORD TO FANGIE JONES * * *

The licensee reported there were no spills or discharges during the offloading process and there was no risk to onsite or offsite personnel at any time. The chemical unloading procedure contains all requirements for personal protective equipment and appropriate precautions. The chemistry department procedure for chemical delivery may be in conflict with Salem UFSAR requirements (Section 2.2.3.3), Hazardous Chemicals - Offsite. Station personnel are evaluating the issue.

The licensee intends to notify the NRC Resident Inspector. The NRC Operations Officer notified the R1DO (Christopher Cahill).

* * * RETRACTION AT 1412 ET ON 09/15/00 BY FRANK SOENS TO JOHN MACKINNON * * *

An assessment of the consequences of a postulated failure of the ammonia tanker with the control room ventilation system being in its normal mode of operation results in a maximum Salem control room concentration of approximately 2.11 ppm which is less than the 100 ppm limit of Reg Guide 1.78. Salem was within the design basis for the given situation, therefore, this event is being retracted. R1DO (Jim Trapp) notified.

The NRC Resident Inspector was notified of this event retraction by the licensee.


Power Reactor
Event Number: 37280
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: FITCH
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/31/2000
Notification Time: 19:42 [ET]
Event Date: 08/24/2000
Event Time: 08:38 [EDT]
Last Update Date: 08/31/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
PETE ESELGROTH (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N N 0 Startup 0 Startup
Event Text
THE CONTROL ROOM EMERGENCY OUTSIDE AIR SYSTEM(CREOAS) FUNCTION IS DEFEATED WHEN THE CONTROL ROOM SMOKE REMOVAL FANS OPERATE.

On August 24, 2000, Susquehanna Unit 1 was Operating at 100% power and Unit 2 was in Mode 2 at 0% power. Operations had placed the Control Structure (CS) Smoke Removal ventilation system in service aligned to the Control Room (CR) and Technical Support Center (TSC) areas to exhaust the foul odor created by welding on the CR ventilation duct as part of modification work. The CS Smoke Removal System was shutdown after personnel noticed a negative differential pressure was created in the CR and TSC areas. This mode of operation existed for 2 hours and 18 minutes. Subsequent review of the event on August 31, 2000 concluded that when the CR Smoke Removal fans operate, they act to defeat the function of the CREOAS fans which are intended to maintain the CS pressure positive. Maintaining a positive pressure in the CS assures that all air entering the CS has passed through the CREOAS filter train (thus assuring no air enters via infiltration).

The NRC Resident Inspector was notified.