Event Notification Report for July 23, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
07/22/2000 - 07/23/2000
Other Nuclear Material
Event Number: 37182
Rep Org: NTH CONSULTANTS
Licensee: NTH CONSULTANTS
Region: 3
City: DETROIT State: MI
County:
License #: 21-14894-01
Agreement: N
Docket:
NRC Notified By: JIM PARSONS
HQ OPS Officer: DOUG WEAVER
Licensee: NTH CONSULTANTS
Region: 3
City: DETROIT State: MI
County:
License #: 21-14894-01
Agreement: N
Docket:
NRC Notified By: JIM PARSONS
HQ OPS Officer: DOUG WEAVER
Notification Date: 07/23/2000
Notification Time: 18:00 [ET]
Event Date: 07/23/2000
Event Time: 12:00 [EDT]
Last Update Date: 07/23/2000
Notification Time: 18:00 [ET]
Event Date: 07/23/2000
Event Time: 12:00 [EDT]
Last Update Date: 07/23/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
MICHAEL PARKER (R3)
PATRICIA HOLAHAN (NMSS)
MICHAEL PARKER (R3)
PATRICIA HOLAHAN (NMSS)
STOLEN TROXLER GAUGE
A model 3440 Troxler moisture/density gauge was stolen along with a company truck from NTH Consultants in Detroit, MI. The theft occurred between noon and 3:30pm on 7/23/00. The gauge contains 8 mCi of Cs-137 and 40 mCi of Am-241. The gauge was chained to the bed of the truck at the time of the theft. A report is being filed with the Detroit Police Department, the Michigan State Police and the State radiation offices will be notified.
A model 3440 Troxler moisture/density gauge was stolen along with a company truck from NTH Consultants in Detroit, MI. The theft occurred between noon and 3:30pm on 7/23/00. The gauge contains 8 mCi of Cs-137 and 40 mCi of Am-241. The gauge was chained to the bed of the truck at the time of the theft. A report is being filed with the Detroit Police Department, the Michigan State Police and the State radiation offices will be notified.
Power Reactor
Event Number: 37183
Facility: SURRY
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: RAWLEIGH DILLARD
HQ OPS Officer: DOUG WEAVER
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: RAWLEIGH DILLARD
HQ OPS Officer: DOUG WEAVER
Notification Date: 07/23/2000
Notification Time: 20:42 [ET]
Event Date: 07/23/2000
Event Time: 20:10 [EDT]
Last Update Date: 07/23/2000
Notification Time: 20:42 [ET]
Event Date: 07/23/2000
Event Time: 20:10 [EDT]
Last Update Date: 07/23/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
BRIAN BONSER (R2)
BRIAN BONSER (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF PLANT COMPUTER
"At 1910 hours on 7/23/00, the Safety Parameter Display System (SPDS) portion of the Emergency Response Facility Computer System (ERFCS) was noted to be inoperable, due to all outputs being displayed in magenta color. Several attempts were made to reboot the system, but were unsuccessful. The air conditioning system for the Technical Support Center (TSC) computer room (which houses the ERFCS) had failed earlier in the day, and the air conditioning system was secured to perform repairs. Portable cooling fans were being used to cool the TSC computer room and the room temperature had stayed at about 80 degrees F. The system must be secured if temperature rises above 85 degrees F.
"Repairs to the TSC computer room air conditioning system are continuing at this time. A return to service time for the SPDS portion of the ERFCS has not been determined at this time."
The licensee will notify the NRC resident inspector.
"At 1910 hours on 7/23/00, the Safety Parameter Display System (SPDS) portion of the Emergency Response Facility Computer System (ERFCS) was noted to be inoperable, due to all outputs being displayed in magenta color. Several attempts were made to reboot the system, but were unsuccessful. The air conditioning system for the Technical Support Center (TSC) computer room (which houses the ERFCS) had failed earlier in the day, and the air conditioning system was secured to perform repairs. Portable cooling fans were being used to cool the TSC computer room and the room temperature had stayed at about 80 degrees F. The system must be secured if temperature rises above 85 degrees F.
"Repairs to the TSC computer room air conditioning system are continuing at this time. A return to service time for the SPDS portion of the ERFCS has not been determined at this time."
The licensee will notify the NRC resident inspector.