Power Reactor
Event Number: 37148
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: DAVID THRONE
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/07/2000
Notification Time: 05:18 [ET]
Event Date: 07/07/2000
Event Time: 02:05 [CDT]
Last Update Date: 08/03/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
MICHAEL JORDAN (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
MAIN CONTROL ROOM HVAC EMERGENCY VENTILATION DECLARED INOPERABLE

"During performance of scheduled monthly surveillance testing, it was determined that overall differential pressure on the Main Control Room HVAC Emergency Ventilation Train Air Filtration Unit (AFU) was out of specification high. The AFU is a single train system required to provide habitable conditions for control room personnel during design basis accident conditions. This condition is reportable under the requirements of SAF 1.17 'Could alone have prevented safety function.' and 10CFR50.72(b). This condition places both Units in a 7 day shutdown LCO."

The licensee will inform the NRC Resident Inspector.

* * * RETRACTION AT 1755 ET ON 08/03/00 BY KEN HOUSH TAKEN BY MACKINNON * * *

A more detailed review performed by Dresden Operations and Engineering personnel has determined that the Differential Pressure across the Air Filtration Unit filter could be up to a maximum of 10 inches of water gauge and perform its design function. The Technical Specification value will be increased to the maximum allowable value (at least 8.0 inches of water gauge); which will remain within the design parameters required for each component of the Control Room HVAC system. The Control Room HVAC system was able to perform its intended safety function and therefore the reportability of CFR 50.72(b)(2)(iii)D does not apply to this condition. NRC R3DO (Jim Creed) notified.

On 07/07/00 at 0205 CT the Control Room HVAC Air Filtration Unit Differential Pressure was found to be at 6.03 inches of water which is above their Technical Specification 3/4.8.D during a routine surveillance test.

The NRC Resident Inspector will be notified of this event retraction by the licensee.


Power Reactor
Event Number: 37150
Facility: COOPER
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: BARTON CROW
HQ OPS Officer: BOB STRANSKY
Notification Date: 07/07/2000
Notification Time: 15:03 [ET]
Event Date: 07/07/2000
Event Time: 13:47 [CDT]
Last Update Date: 07/07/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(i)(A) - PLANT S/D REQD BY TS
Person (Organization):
DAVID GRAVES (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 88 Power Operation
Event Text
PLANT SHUTDOWN REQUIRED BY TECHNICAL SPECIFICATIONS

"This report is being made in order to comply with the requirements of 10CFR50.72(b)(1)(i)A due to the initiation of a Technical Specification Required Plant Shutdown.

"At 0831 CDT while operating at 100% power Reactor Equipment Cooling (REC) Pump 'C' unexpectedly tripped. This condition required entering Technical Specification LCO 3.7.3 Condition B due to both REC subsystems being Inoperable. REC pump 'C' is in Division 2 of REC. Division 1 of REC had been declared Inoperable on 7-5-2000 at 2134 when REC pump 'A' tripped.

"The Required Actions of LCO 3.7.3 Condition B require the Plant to be in Mode 3 in 12 hours and Mode 4 in 36 hours. The first power drop occurred at 1347 CDT.

"The electrical grid is stable at this time. The cause of the REC pump 'C' trip is currently under investigation. It is suspected the thermal overloads on REC Pump 'A' are the cause of that pump trip and they are being replaced at this time."

The NRC resident inspector has been informed of this event by the licensee.

* * * UPDATE 1848 7/7/00 FROM CROW TAKEN BY STRANSKY * * *

"At 1545, both REC subsystems were declared Operable. This was based on an operability determination requiring the operation of all four REC pumps, which will add margin to where the pumps are operating compared to the thermal overload setpoints. The Technical Specification shutdown was exited at that time. Power had been lowered to approximately 80% prior to both REC subsystems being declared Operable. The return to 100% power is in progress."

The NRC resident inspector has been informed of this event by the licensee. Notified R4DO (Graves).