Event Notification Report for June 27, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/26/2000 - 06/27/2000
EVENT NUMBERS
371213712237123371253712637135
Power Reactor
Event Number: 37121
Facility: WNP-2
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: DAVE SWANK
HQ OPS Officer: FANGIE JONES
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: DAVE SWANK
HQ OPS Officer: FANGIE JONES
Notification Date: 06/27/2000
Notification Time: 11:57 [ET]
Event Date: 06/27/2000
Event Time: 05:30 [PDT]
Last Update Date: 06/27/2000
Notification Time: 11:57 [ET]
Event Date: 06/27/2000
Event Time: 05:30 [PDT]
Last Update Date: 06/27/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
GAIL GOOD (R4)
GAIL GOOD (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
MAIN STEAM ISOLATION VALVES (MSIVs) ISOLATED DUE TO SPURIOUS GROUP 1 ISOLATION SIGNAL
"This event is being reported per 10CFR50.72(b)(2)(ii).
"At 0530 hours the MSIVs inadvertently isolated due to a spurious group 1 primary containment isolation valve logic (NS4) signal.
"In support of required surveillance testing of RPS EPA breakers, RPS 'B' bus had been transferred to normal from its alternate power supply. NS4 'B' isolation logic was inadvertently not reset as part of the restoration following this power supply transfer. When bus RPS 'A' was de-energized as part of the planned transfer to the alternate power supply it caused the NS4 'A' isolation logic relays to de-energize and resulted in a closure signal to all MSIVs. All eight MSIVs closed as expected.
"The plant was in Mode 4 at approximately 180°F at the time of the event. Shutdown cooling had been removed from service in preparation for the power supply transfer. Following reset of the NS4 isolation logic. shutdown cooling was restored with the reactor coolant temperature at approximately 187°F. The MSIVs may be re-opened as needed,"
The licensee notified the NRC Resident Inspector.
"This event is being reported per 10CFR50.72(b)(2)(ii).
"At 0530 hours the MSIVs inadvertently isolated due to a spurious group 1 primary containment isolation valve logic (NS4) signal.
"In support of required surveillance testing of RPS EPA breakers, RPS 'B' bus had been transferred to normal from its alternate power supply. NS4 'B' isolation logic was inadvertently not reset as part of the restoration following this power supply transfer. When bus RPS 'A' was de-energized as part of the planned transfer to the alternate power supply it caused the NS4 'A' isolation logic relays to de-energize and resulted in a closure signal to all MSIVs. All eight MSIVs closed as expected.
"The plant was in Mode 4 at approximately 180°F at the time of the event. Shutdown cooling had been removed from service in preparation for the power supply transfer. Following reset of the NS4 isolation logic. shutdown cooling was restored with the reactor coolant temperature at approximately 187°F. The MSIVs may be re-opened as needed,"
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 37122
Facility: OYSTER CREEK
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: FRANK CIGANIK
HQ OPS Officer: STEVE SANDIN
Region: 1 State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: FRANK CIGANIK
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/27/2000
Notification Time: 12:04 [ET]
Event Date: 06/27/2000
Event Time: 09:30 [EDT]
Last Update Date: 06/27/2000
Notification Time: 12:04 [ET]
Event Date: 06/27/2000
Event Time: 09:30 [EDT]
Last Update Date: 06/27/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
SCOTT MORRIS (R1)
SCOTT MORRIS (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 85 | Power Operation |
NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION (NJ DEP) NOTIFIED OF EFFLUENT DISCHARGE TEMPERATURE VIOLATION
ON 6/26/00 AT 1844EDT AND 1859EDT, EFFLUENT DISCHARGE TEMPERATURE WAS MEASURED AT 106.62 AND 106.60 DEGREES F. THIS EXCEEDS THE LIMIT OF 106 +0.5 DEGREES F WHICH REQUIRES NOTIFICATION TO NJ DEP. CORRECTIVE ACTION TAKEN INCLUDED LOWERING POWER TO REDUCE EFFLUENT TEMPERATURE. THE LICENSEE ALSO INTENDS TO CHECK THE ALARM SETPOINTS.
THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.
ON 6/26/00 AT 1844EDT AND 1859EDT, EFFLUENT DISCHARGE TEMPERATURE WAS MEASURED AT 106.62 AND 106.60 DEGREES F. THIS EXCEEDS THE LIMIT OF 106 +0.5 DEGREES F WHICH REQUIRES NOTIFICATION TO NJ DEP. CORRECTIVE ACTION TAKEN INCLUDED LOWERING POWER TO REDUCE EFFLUENT TEMPERATURE. THE LICENSEE ALSO INTENDS TO CHECK THE ALARM SETPOINTS.
THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.
Power Reactor
Event Number: 37123
Facility: SEABROOK
Region: 1 State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DENNIS BEMIS
HQ OPS Officer: STEVE SANDIN
Region: 1 State: NH
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DENNIS BEMIS
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/27/2000
Notification Time: 14:17 [ET]
Event Date: 06/27/2000
Event Time: 14:00 [EDT]
Last Update Date: 06/27/2000
Notification Time: 14:17 [ET]
Event Date: 06/27/2000
Event Time: 14:00 [EDT]
Last Update Date: 06/27/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
Person (Organization):
SCOTT MORRIS (R1)
SCOTT MORRIS (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Hot Standby | 0 | Hot Standby |
EMERGENCY SIRENS INOPERABLE DUE TO PLANNED MAINTENANCE
"PLANNED LOSS OF POWER TO THE NEWINGTON SIREN ACTIVATION CONTROL REPEATER FOR GREATER THAN 1 HOUR. POWER SHOULD BE RESTORED WITHIN 1-2 HOURS. THE EOF LOST CAPABILITY TO ALL 94 SIRENS TO BE ACTIVATED. EACH LOCAL COMMUNITY STILL HAD THE ABILITY TO ACTIVATE THEIR RESPECTIVE SIRENS."
THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.
"PLANNED LOSS OF POWER TO THE NEWINGTON SIREN ACTIVATION CONTROL REPEATER FOR GREATER THAN 1 HOUR. POWER SHOULD BE RESTORED WITHIN 1-2 HOURS. THE EOF LOST CAPABILITY TO ALL 94 SIRENS TO BE ACTIVATED. EACH LOCAL COMMUNITY STILL HAD THE ABILITY TO ACTIVATE THEIR RESPECTIVE SIRENS."
THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.
Power Reactor
Event Number: 37125
Facility: WNP-2
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: OJ BROOKS
HQ OPS Officer: STEVE SANDIN
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: OJ BROOKS
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/27/2000
Notification Time: 20:35 [ET]
Event Date: 06/27/2000
Event Time: 15:29 [PDT]
Last Update Date: 06/27/2000
Notification Time: 20:35 [ET]
Event Date: 06/27/2000
Event Time: 15:29 [PDT]
Last Update Date: 06/27/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
GAIL GOOD (R4)
GAIL GOOD (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
MAIN STEAM ISOLATION VALVES CLOSED
"The Main Steam Isolation Valves closed due to Low Vacuum closure isolation signal. The low vacuum isolation logic had not been completely bypassed as required by PPM 3.2.1, prior to breaking main condenser vacuum.
"The RPV is in Shutdown Cooling at 137°F cooling down to a band of 100 to 120°F. Shutdown cooling was not impacted by the isolation."
The licensee informed the NRC Resident Inspector.
"The Main Steam Isolation Valves closed due to Low Vacuum closure isolation signal. The low vacuum isolation logic had not been completely bypassed as required by PPM 3.2.1, prior to breaking main condenser vacuum.
"The RPV is in Shutdown Cooling at 137°F cooling down to a band of 100 to 120°F. Shutdown cooling was not impacted by the isolation."
The licensee informed the NRC Resident Inspector.
Power Reactor
Event Number: 37126
Facility: HARRIS
Region: 2 State: NC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: DOUG SCHROEDER
HQ OPS Officer: STEVE SANDIN
Region: 2 State: NC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: DOUG SCHROEDER
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/27/2000
Notification Time: 22:00 [ET]
Event Date: 06/27/2000
Event Time: 21:25 [EDT]
Last Update Date: 06/27/2000
Notification Time: 22:00 [ET]
Event Date: 06/27/2000
Event Time: 21:25 [EDT]
Last Update Date: 06/27/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
Person (Organization):
CAUDLE JULIAN (R2)
CAUDLE JULIAN (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
LOSS OF EMERGENCY SIRENS DUE TO ADVERSE WEATHER
"At 2125 Notified by Emergency Preparedness that Chatam County lost all Siren Capability for a period of 8 minutes due to a lightning strike. Siren capability has been restored."
The licensee informed the NRC Resident Inspector.
"At 2125 Notified by Emergency Preparedness that Chatam County lost all Siren Capability for a period of 8 minutes due to a lightning strike. Siren capability has been restored."
The licensee informed the NRC Resident Inspector.
General Information or Other
Event Number: 37135
Rep Org: TEXAS DEPARTMENT OF HEALTH
Licensee: RADIOGRAPHIC SPECIALISTS, INC.
Region: 4
City: HOUSTON State: TX
County:
License #: L02742
Agreement: Y
Docket:
NRC Notified By: HELEN WATKINS (FACSIMILE)
HQ OPS Officer: BOB STRANSKY
Licensee: RADIOGRAPHIC SPECIALISTS, INC.
Region: 4
City: HOUSTON State: TX
County:
License #: L02742
Agreement: Y
Docket:
NRC Notified By: HELEN WATKINS (FACSIMILE)
HQ OPS Officer: BOB STRANSKY
Notification Date: 06/29/2000
Notification Time: 16:51 [ET]
Event Date: 06/27/2000
Event Time: 00:00 [CDT]
Last Update Date: 06/29/2000
Notification Time: 16:51 [ET]
Event Date: 06/27/2000
Event Time: 00:00 [CDT]
Last Update Date: 06/29/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
GAIL GOOD (R4)
JOHN HICKEY (NMSS)
GAIL GOOD (R4)
JOHN HICKEY (NMSS)
AGREEMENT STATE REPORT
The film badge of a radiographer for Radiographic Specialists, Houston, TX, received an exposure of 5.755R during the period from 5/10/00-6/9/00. The licensee reported that the individual may have left the film badge clipped to his shirt in a high radiation area. The State of Texas is investigating the incident.
The film badge of a radiographer for Radiographic Specialists, Houston, TX, received an exposure of 5.755R during the period from 5/10/00-6/9/00. The licensee reported that the individual may have left the film badge clipped to his shirt in a high radiation area. The State of Texas is investigating the incident.