Event Notification Report for June 11, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
06/10/2000 - 06/11/2000

EVENT NUMBERS
37091

Power Reactor
Event Number: 37091
Facility: SAN ONOFRE
Region: 4     State: CA
Unit: [] [2] [3]
RX Type: [1] W-3-LP,[2] CE,[3] CE
NRC Notified By: ANDY BOLYEN
HQ OPS Officer: STEVE SANDIN
Notification Date: 06/16/2000
Notification Time: 17:28 [ET]
Event Date: 06/11/2000
Event Time: 13:13 [PDT]
Last Update Date: 06/16/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
LINDA SMITH (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
ACTUATION OF THE CONTROL ROOM EMERGENCY AIR CLEANUP SYSTEM DURING RADIOGRAPHY

"On June 11, 2000, at approximately 1313 PDT, SCE was performing radiography on the 56' elevation of the Unit 2 Turbine Building when the Train B radiation monitor (2/3RT7824) for the Control Room Isolation Signal (CRIS) actuated. At approximately 1317 PDT, the Train A CRIS radiation monitor (2/3RT7825) actuated. The Train A and B Control Room Emergency Air Cleanup System (CREACUS) actuated as expected.

"SCE was performing the radiography on the Unit 2 Main Steam Throttle Stop Valves with an 82 Ci iridium-192 source. The unshielded beam emanating from the collimated radiographic source was directed away from the CRIS radiation monitors, which are about 150 feet away. The radiography was scheduled to last approximately 3.5 minutes.

"Because the actuation of the CRIS radiation monitors did not occur as a result of airborne contamination or actual plant conditions or parameters satisfying the requirements for initiation of the safety function of the system, SCE did not consider this to be a valid actuation requiring a report. However, if a 'valid signal' were to be defined as output from a radiation monitor detecting any radiation source, then this event would be reportable. Because questions have been raised regarding which definition of 'valid signal' is applicable in this instance, SCE is conservatively reporting this condition in accordance with 10CFR50.72(b2)(ii).

"The trend data for the CRIS radiation monitors showed no readings above the setpoint of 1E-5 µCi/cc. Because no actual airborne radioactive contamination was present, this event has no safety significance.

"At the time of this occurrence, both Units 2 and 3 were operating at about 100 percent power; Unit 1 remains permanently defueled. SCE will notify the NRC resident inspectors about this notification and will provide them with a copy of this report."