Event Notification Report for June 07, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/06/2000 - 06/07/2000
EVENT NUMBERS
3706437065370663706737100
Power Reactor
Event Number: 37064
Facility: GRAND GULF
Region: 4 State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: WEAVER
HQ OPS Officer: JOHN MacKINNON
Region: 4 State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: WEAVER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 06/07/2000
Notification Time: 15:36 [ET]
Event Date: 06/07/2000
Event Time: 13:42 [CDT]
Last Update Date: 06/07/2000
Notification Time: 15:36 [ET]
Event Date: 06/07/2000
Event Time: 13:42 [CDT]
Last Update Date: 06/07/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
JOHN PELLET (R4)
JOHN PELLET (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
SAFETY PARAMETER DISPLAY SYSTEM (SPDS) BREAKER OPENED CAUSING A LOSS OF INPUTS TO THE CONTROL ROOM TERMINAL.
CONTROL ROOM EXPERIENCED A LOSS OF SPDS DUE TO A BREAKER TRIPPING WHICH SUPPLIES POWER TO THE CONTROL ROOM SPDS TERMINAL. INVESTIGATION OF WHY THE BREAKER TRIPPED AND RESET IS UNDERWAY. SHORTLY BEFORE THE BREAKER TRIPPED A CARPET CLEANER WAS ENERGIZED IN THE CONTROL ROOM.
THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED OF THIS EVENT BY THE LICENSEE.
* * * UPDATE ON 06/07/00 AT 1728 ET BY WEAVER TAKEN BY MACKINNON * * *
SPDS WAS RETURNED TO SERVICE AT 1608 CDT. IT WAS DISCOVERED THAT A FUSE HAD BLOWN INSTEAD OF A BREAKER OPENING. THE FUSE WAS REPLACED AND THE SPDS WAS RETURNED TO SERVICE. R4DO (PELLET) NOTIFIED.
THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS UPDATE BY THE LICENSEE.
CONTROL ROOM EXPERIENCED A LOSS OF SPDS DUE TO A BREAKER TRIPPING WHICH SUPPLIES POWER TO THE CONTROL ROOM SPDS TERMINAL. INVESTIGATION OF WHY THE BREAKER TRIPPED AND RESET IS UNDERWAY. SHORTLY BEFORE THE BREAKER TRIPPED A CARPET CLEANER WAS ENERGIZED IN THE CONTROL ROOM.
THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED OF THIS EVENT BY THE LICENSEE.
* * * UPDATE ON 06/07/00 AT 1728 ET BY WEAVER TAKEN BY MACKINNON * * *
SPDS WAS RETURNED TO SERVICE AT 1608 CDT. IT WAS DISCOVERED THAT A FUSE HAD BLOWN INSTEAD OF A BREAKER OPENING. THE FUSE WAS REPLACED AND THE SPDS WAS RETURNED TO SERVICE. R4DO (PELLET) NOTIFIED.
THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS UPDATE BY THE LICENSEE.
Power Reactor
Event Number: 37065
Facility: SURRY
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: LISA HILBERT-SEMMES
HQ OPS Officer: JOHN MacKINNON
Region: 2 State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: LISA HILBERT-SEMMES
HQ OPS Officer: JOHN MacKINNON
Notification Date: 06/07/2000
Notification Time: 19:28 [ET]
Event Date: 06/07/2000
Event Time: 17:55 [EDT]
Last Update Date: 06/07/2000
Notification Time: 19:28 [ET]
Event Date: 06/07/2000
Event Time: 17:55 [EDT]
Last Update Date: 06/07/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
72.75 - SPENT FUEL CASK EVENT
10 CFR Section:
72.75 - SPENT FUEL CASK EVENT
Person (Organization):
CHARLES OGLE (R2)
WILLIAM BRACH (NMSS)
CHARLES OGLE (R2)
WILLIAM BRACH (NMSS)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
DEFECT IN A SPENT FUEL STORAGE CASK STRUCTURE
At 1755 hours, as a result of troubleshooting due to a low pressure alarm at the Surry ISFSI Facility, it was determined that a leak existed in the lid seal system on Dry Storage Cask #2-3 which exceeds the ISFSI Tech Spec limit of 1E-5mbar-l/sec. This is a TN-32.01 cask that was placed at the Surry ISFSI Facility, pad #2 in 1996. It has been verified that the cask's overpressure monitoring system does not leak and continued to maintain a pressure greater than the cask's internal fuel cavity pressure. Therefore, it was not possible for any release of potentially radioactive material as a result of a seal failure. The cask was returned from the ISFSI pad to the station on Friday, June 2, 2000 due to the low pressure alarm. Radiation levels at the cask prior to transport to the station were normal. Additional tests are being conducted to determine which seal (either inner or outer) is affected. Investigation is on going for determining the cause and required corrective actions for this issue. Both Unit 1 and Unit 2 are currently at 100% power. Pursuant to 10CFR72.75(b)(2), this is being reported as a defect in a spent fuel storage cask structure, system, or component that is important to safety.
The NRC Resident Inspector was notified of this event by the licensee.
At 1755 hours, as a result of troubleshooting due to a low pressure alarm at the Surry ISFSI Facility, it was determined that a leak existed in the lid seal system on Dry Storage Cask #2-3 which exceeds the ISFSI Tech Spec limit of 1E-5mbar-l/sec. This is a TN-32.01 cask that was placed at the Surry ISFSI Facility, pad #2 in 1996. It has been verified that the cask's overpressure monitoring system does not leak and continued to maintain a pressure greater than the cask's internal fuel cavity pressure. Therefore, it was not possible for any release of potentially radioactive material as a result of a seal failure. The cask was returned from the ISFSI pad to the station on Friday, June 2, 2000 due to the low pressure alarm. Radiation levels at the cask prior to transport to the station were normal. Additional tests are being conducted to determine which seal (either inner or outer) is affected. Investigation is on going for determining the cause and required corrective actions for this issue. Both Unit 1 and Unit 2 are currently at 100% power. Pursuant to 10CFR72.75(b)(2), this is being reported as a defect in a spent fuel storage cask structure, system, or component that is important to safety.
The NRC Resident Inspector was notified of this event by the licensee.
Power Reactor
Event Number: 37066
Facility: TURKEY POINT
Region: 2 State: FL
Unit: [3] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: MATUSZEWSKI
HQ OPS Officer: JOHN MacKINNON
Region: 2 State: FL
Unit: [3] [4] []
RX Type: [3] W-3-LP,[4] W-3-LP
NRC Notified By: MATUSZEWSKI
HQ OPS Officer: JOHN MacKINNON
Notification Date: 06/07/2000
Notification Time: 20:25 [ET]
Event Date: 06/07/2000
Event Time: 20:00 [EDT]
Last Update Date: 06/07/2000
Notification Time: 20:25 [ET]
Event Date: 06/07/2000
Event Time: 20:00 [EDT]
Last Update Date: 06/07/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
CHARLES OGLE (R2)
CHARLES OGLE (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 4 | N | Y | 100 | Power Operation | 100 | Power Operation |
AT 2000 HOURS IT WAS NOTED THAT THE EMERGENCY RESPONSE DATA ACQUISITION DISPLAY SYSTEM (ERDADS) DATA LINK TO THE EMERGENCY RESPONSE DATA SYSTEM WAS DOWN (LOCKED UP). PERSONNEL HAVE BEEN CALLED TO COME IN AND REPAIR THE ERDADS SYSTEM.
THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED OF THIS EVENT BY THE LICENSEE.
* * * UPDATE ON 06/07/00 AT 2159 ET BY FREW TAKEN BY MACKINNON * * *
ERDADS RETURNED TO SERVICE AT 2157 ET (ERDADS HAD LOCKED UP).
THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS UPDATE BY THE LICENSEE.
THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED OF THIS EVENT BY THE LICENSEE.
* * * UPDATE ON 06/07/00 AT 2159 ET BY FREW TAKEN BY MACKINNON * * *
ERDADS RETURNED TO SERVICE AT 2157 ET (ERDADS HAD LOCKED UP).
THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS UPDATE BY THE LICENSEE.
Power Reactor
Event Number: 37067
Facility: BEAVER VALLEY
Region: 1 State: PA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: RICH DIBLER
HQ OPS Officer: LEIGH TROCINE
Region: 1 State: PA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: RICH DIBLER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 06/08/2000
Notification Time: 11:09 [ET]
Event Date: 06/07/2000
Event Time: 11:16 [EDT]
Last Update Date: 06/08/2000
Notification Time: 11:09 [ET]
Event Date: 06/07/2000
Event Time: 11:16 [EDT]
Last Update Date: 06/08/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
TOM MOSLAK (R1)
TOM MOSLAK (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
LICENSEE EMPLOYEE TESTED POSITIVE FOR ALCOHOL DURING A RANDOM FITNESS-FOR-DUTY TEST (24-HOUR REPORT)
A non-licensed employee tested positive for alcohol during a random fitness-for-duty test conducted on 06/07/00. The individual has been relieved of duty and placed on indefinite suspension. The individual's access authorization has been suspended, and the licensee is currently reviewing the individual's activities. (Call the NRC operations officer for additional information.)
The licensee notified the NRC resident inspector.
A non-licensed employee tested positive for alcohol during a random fitness-for-duty test conducted on 06/07/00. The individual has been relieved of duty and placed on indefinite suspension. The individual's access authorization has been suspended, and the licensee is currently reviewing the individual's activities. (Call the NRC operations officer for additional information.)
The licensee notified the NRC resident inspector.
Other Nuclear Material
Event Number: 37100
Rep Org: DNX TRANSGENIC SCIENCES
Licensee: DNX TRANSGENIC SCIENCES
Region: 1
City: CRANBURY State: NJ
County:
License #: 29-30350-01
Agreement: N
Docket:
NRC Notified By: JOE D'IPPOLITO, RSO
HQ OPS Officer: DICK JOLLIFFE
Licensee: DNX TRANSGENIC SCIENCES
Region: 1
City: CRANBURY State: NJ
County:
License #: 29-30350-01
Agreement: N
Docket:
NRC Notified By: JOE D'IPPOLITO, RSO
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 06/21/2000
Notification Time: 10:35 [ET]
Event Date: 06/07/2000
Event Time: 11:00 [EDT]
Last Update Date: 06/21/2000
Notification Time: 10:35 [ET]
Event Date: 06/07/2000
Event Time: 11:00 [EDT]
Last Update Date: 06/21/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
ROBERT SUMMERS (R1)
BOB AYRES (NMSS)
ROBERT SUMMERS (R1)
BOB AYRES (NMSS)
- LOSS OF LICENSED MATERIAL -
On 06/02/00, one vial of 500 µCi of [alpha-32] deoxycytidine 5'-Triphosphate (dCTP) was received at DNX Transgenic Sciences, Cranbury, NJ. The concentration of the material was 10 µCi/µl. Upon arrival, this vial was designated as vial #153. At 1130 on 06/07/00, Roland Felkner, a DNX Transgenic Sciences research associate, was planning to remove 50 µCi of material from this vial to do a DNA labeling experiment. However, he discovered that there was no material in the vial. According to the isotope inventory log of vial #153, there should have been 150 µCi of the 500 µCi still available in the vial. Upon investigation, it was determined that 200 µCi, rather than 150 µCi, was actually missing. This error is attributed to a computational mistake made in the log by another research associate.
Joe D'Ippolito, DNX Transgenic Sciences Radiation Safety Officer (RSO), interviewed lab personnel, conducted a survey of the lab area and performed an internal investigation to locate the missing material. There was no indication of radiation exposure to lab personnel. Based on the results of the investigation, the RSO and members of the DNX Transgenic Sciences Radiation Safety Committee believe that less material had been sent in vial #153 by their supplier, NEN Life Science Product, than was reported on the vial label.
The RSO is continuing his investigation and will determine corrective actions.
On 06/02/00, one vial of 500 µCi of [alpha-32] deoxycytidine 5'-Triphosphate (dCTP) was received at DNX Transgenic Sciences, Cranbury, NJ. The concentration of the material was 10 µCi/µl. Upon arrival, this vial was designated as vial #153. At 1130 on 06/07/00, Roland Felkner, a DNX Transgenic Sciences research associate, was planning to remove 50 µCi of material from this vial to do a DNA labeling experiment. However, he discovered that there was no material in the vial. According to the isotope inventory log of vial #153, there should have been 150 µCi of the 500 µCi still available in the vial. Upon investigation, it was determined that 200 µCi, rather than 150 µCi, was actually missing. This error is attributed to a computational mistake made in the log by another research associate.
Joe D'Ippolito, DNX Transgenic Sciences Radiation Safety Officer (RSO), interviewed lab personnel, conducted a survey of the lab area and performed an internal investigation to locate the missing material. There was no indication of radiation exposure to lab personnel. Based on the results of the investigation, the RSO and members of the DNX Transgenic Sciences Radiation Safety Committee believe that less material had been sent in vial #153 by their supplier, NEN Life Science Product, than was reported on the vial label.
The RSO is continuing his investigation and will determine corrective actions.