Event Notification Report for May 23, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/22/2000 - 05/23/2000

EVENT NUMBERS
37020370213702237024

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37020
Facility: SAN ONOFRE
Region: 4     State: CA
Unit: [] [2] [3]
RX Type: [1] W-3-LP,[2] CE,[3] CE
NRC Notified By: JACK FITCH
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 05/23/2000
Notification Time: 06:10 [ET]
Event Date: 05/23/2000
Event Time: 02:00 [PDT]
Last Update Date: 05/23/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
CLAUDE JOHNSON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
PHYSICAL SECURITY REPORT -

UNSECURED/UNATTENDED SECURITY GUARD WEAPON AND AMMUNITION INSIDE PLANT PROTECTED AREA FOR ABOUT 25 MINUTES. COMPENSATORY MEASURES WERE IMMEDIATELY TAKEN UPON DISCOVERY. THE LICENSEE PLANS TO NOTIFY THE NRC RESIDENT INSPECTOR. CONTACT THE NRC OPERATIONS OFFICER FOR ADDITIONAL DETAILS.

* * * UPDATE ON 5/23/00 @ 1342 BY PLUMLEE TO GOULD * * * RETRACTION

LICENSEE IS RETRACTING THIS EVENT SINCE NO WEAPON WAS LOST.

THE NRC RESIDENT INSPECTOR WILL BE INFORMED. THE REG 4 RDO (JOHNSON) WAS NOTIFIED.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 37021
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: ART BREADY
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 05/23/2000
Notification Time: 08:44 [ET]
Event Date: 05/23/2000
Event Time: 05:05 [EDT]
Last Update Date: 06/08/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(C) - POT UNCNTRL RAD REL
Person (Organization):
DAN HOLODY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 4 Startup 4 Startup
Event Text
- HIGH PRESSURE COOLANT INJECTION SYSTEM INOPERABLE DUE TO STUCK OPEN CHECK VALVE -

At 0505 on 05/23/00, the High Pressure Coolant Injection (HPCI) System was determined to be inoperable as a result of the discharge check valve being stuck partially open. This condition was discovered during investigation of a low injection header pressure alarm, and subsequent attempts to fill and vent the discharge header were unsuccessful. It is believed that the check valve stuck partially open when the system was secured after a low pressure surveillance test at about 0305. The discharge check valve was mechanically agitated at 0700, and reseated as evidenced by an audible sound and rise in injection header pressure.

At the time of discovery, the plant was in Operational Condition 2 with reactor power at 4% and reactor pressure at approximately 500 psig. All other safety related equipment was operable at the tune of discovery, with the exception of the 'A' Residual Heat Removal Pump, which was aligned for suppression pool cooling mode of operation. There was no significant impact to overall plant safety as a result of this condition.

Plant maintenance and engineering personnel are currently evaluating the failure of the HPCI System discharge check valve. injection header fill and vent is in progress to determine the amount of air that is present and restore the system to an available condition. This information will be used to determine if the safety function of the HPCI System was unavailable as a result of the discharge check valve malfunction.

A root cause investigation team has been assembled, and evaluation of system and personnel performance is in progress.

The licensee notified the NRC Resident Inspector and plans to notify local officials.

* * * UPDATE ON 6/8/00 @ 1219 BY CONICELLA TO GOULD * * * RETRACTION



As discussed in the notification. the HPCI low discharge header pressure alarm was received, prompting an immediate investigation. The discharge check valve was mechanically agitated which resulted in the seating of the valve and clearing of the alarm. Sticking of the discharge check Valve provided a leakage path thus preventing the keep fill system from achieving pressure sufficient to clear the alarm setpoint. The amount of mechanical agitation required was minimal. HPCI was then removed from service to allow maintenance troubleshooting on the valve.

It is believed that the discharge check valve stuck in the partially open position following the low pressure response time surveillance testing which had been completed approximately two hours prior to the event. This was a result of the low delta P across the valve associated with that testing. Prior to the cited surveillance test, a different HPCl surveillance (HPCI Flowpath Verification) had been successfully completed and HPCI had been determined to be operable. Investigation of the valve revealed very minor misalignment which may have been the cause at the slight binding. This condition would not prevent the safety function of HPCI from being performed. Following the investigation HPCI was removed from service and the plant entered a 14 day LCO. The valve was repaired and HPCI was retested and declared operable. The keep fill system was always sufficient.


The NRC Resident Inspector will be notified. The Reg 1 RDO (Moslak) was notified.


Power Reactor
Event Number: 37022
Facility: COMANCHE PEAK
Region: 4     State: TX
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHRIS ALEXANDER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 05/23/2000
Notification Time: 11:07 [ET]
Event Date: 05/23/2000
Event Time: 09:40 [CDT]
Last Update Date: 05/23/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
CLAUDE JOHNSON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
DISCOVERY OF A LOOSE CONNECTION WHICH CAUSED INOPERABLE PROCESS COMPUTER SYSTEM (PCS) SITE DATA SYSTEM (SDS) COMMUNICATION IN THE EMERGENCY OPERATIONS FACILITY (EOF)

The following test is a portion of a facsimile received from the licensee:

"During troubleshooting of an unrelated LAN problem, Telecommunications [personnel] apparently bumped a cable causing the connection to become loose. This loose connection caused the communication to TT10 and TT11 PCS SDS in the EOF to become inoperable. The SDSs were inoperable from 05/22/00 [at] 1523 [CST] to 05/23/00 [at] 0739 [CST] for a total of 16 [hours and] 16 [minutes]."

The licensee stated that the control room was notified of this condition at 0940 CST on 05/23/00.

The licensee notified the NRC resident inspector.


General Information or Other
Event Number: 37024
Rep Org: CALIFORNIA DEPT OF HEALTH SERVICES
Licensee: STERIGENICS INTERNATIONAL
Region: 4
City: HAYWARD   State: CA
County:
License #: 6268-01
Agreement: Y
Docket:
NRC Notified By: PENDERGAST
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 05/24/2000
Notification Time: 13:10 [ET]
Event Date: 05/23/2000
Event Time: 12:29 [PDT]
Last Update Date: 05/24/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CLAUDE JOHNSON (R4)
DON COOL (NMSS)
Event Text
THE RADIOLOGICAL HEALTH BRANCH OF THE CALIFORNIA DEPARTMENT OF HEALTH SERVICES WAS NOTIFIED BY STERIGENICS INTERNATIONAL THAT THEY HAD A CABLE JAM ON THEIR SOURCE HOIST ARRAY.

THIS OCCURRED ON THEIR 600,000 CURIE POOL IRRADIATOR WHILE THEY WERE LOWERING THE SOURCE ARRAY INTO THE SHIELDED POSITION AND THE SOURCE HOIST CABLE JAMMED DUE TO A FRAY ON THE CABLE. THEY LOOSENED THE SHIELDING AROUND THE SOURCE HOIST CABLE AND THAT ALLOWED THE SOURCES TO BE RETURNED TO THE SAFE POSITION. THERE WERE NO OVEREXPOSURES AND NO ABNORMAL RADIATION LEVELS. THE PLANT WAS SHUTDOWN UNTIL MAINTENANCE WAS COMPLETED THIS MORNING @ 6:00.