Event Notification Report for May 17, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
05/16/2000 - 05/17/2000
Other Nuclear Material
Event Number: 37011
Rep Org: OKLAHOMA GAS & ELECTRIC
Licensee: OKLAHOMA GAS & ELECTRIC
Region: 4
City: State: OK
County: MUSKOGEE
License #: 35-19819-03
Agreement: N
Docket:
NRC Notified By: B. W. HALL
HQ OPS Officer: BOB STRANSKY
Licensee: OKLAHOMA GAS & ELECTRIC
Region: 4
City: State: OK
County: MUSKOGEE
License #: 35-19819-03
Agreement: N
Docket:
NRC Notified By: B. W. HALL
HQ OPS Officer: BOB STRANSKY
Notification Date: 05/18/2000
Notification Time: 17:16 [ET]
Event Date: 05/17/2000
Event Time: 00:00 [CDT]
Last Update Date: 05/18/2000
Notification Time: 17:16 [ET]
Event Date: 05/17/2000
Event Time: 00:00 [CDT]
Last Update Date: 05/18/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
BILL JONES (R4)
BILL REAMER (NMSS)
FRANK CONGEL (IRO)
BILL JONES (R4)
BILL REAMER (NMSS)
FRANK CONGEL (IRO)
MISSING RADIOACTIVE SOURCE
The licensee reported that a 200 mCi Cs-137 source was discovered to be missing from a group of sources removed from the Muskogee Power Plant for disposal. Several Omart model SHDP source holders (with sources) were transferred to Radiation Technology, Inc., a contractor, for disposal. These source holders had been stored in a warehouse at the power plant for some time before being transferred to the contractor. The licensee was notified on 5/17/2000 by the contractor that one of the source holders was empty. The licensee has searched their facility for the source but has been unable to locate it.
The licensee has already contacted NRC Region 4 (L. Howell).
The licensee reported that a 200 mCi Cs-137 source was discovered to be missing from a group of sources removed from the Muskogee Power Plant for disposal. Several Omart model SHDP source holders (with sources) were transferred to Radiation Technology, Inc., a contractor, for disposal. These source holders had been stored in a warehouse at the power plant for some time before being transferred to the contractor. The licensee was notified on 5/17/2000 by the contractor that one of the source holders was empty. The licensee has searched their facility for the source but has been unable to locate it.
The licensee has already contacted NRC Region 4 (L. Howell).
Power Reactor
Event Number: 37008
Facility: CLINTON
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: VINCE PATTEN
HQ OPS Officer: FANGIE JONES
Region: 3 State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: VINCE PATTEN
HQ OPS Officer: FANGIE JONES
Notification Date: 05/17/2000
Notification Time: 12:56 [ET]
Event Date: 05/17/2000
Event Time: 09:14 [CDT]
Last Update Date: 05/17/2000
Notification Time: 12:56 [ET]
Event Date: 05/17/2000
Event Time: 09:14 [CDT]
Last Update Date: 05/17/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
JOHN MADERA (R3)
JOHN MADERA (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 100 | Power Operation | 0 | Hot Shutdown |
MANUAL REACTOR TRIP AFTER LOSS OF TWO CONDENSATE PUMPS
The licensee was performing preventative maintenance on electrical equipment when an error caused the loss of the '1B' 4160 volt non-vital bus. When the bus deenergized, two condensate pumps were lost resulting in loss of feed to the reactor. The operators manually scrammed the reactor, all rods fully inserted and the plant is stable in Mode 3 with level control from the balance of the condensate and feed system. Pressure control is by RCIC supplemented by SRVs as needed. The plant is continuing to Cold Shutdown and an investigation into the initiating event is pending.
A press release is planned by the licensee. The licensee has notified the local and state authorities as well as the NRC Resident Inspector.
* * * UPDATE AT 1547 EDT ON 5/17/00 BY VINCE PATTEN TO FANGIE JONES * * *
During the plant cooldown received a MSIV closure signal due to low vacuum as a result of breaking vacuum as a result of loss of seal steam to the main turbine.
RHR reject to radwaste, 1E12-F049, automatically isolated on a level 3 signal due to momentary reactor vessel level shrink from SRV operations.
The licensee is continuing to cooldown the plant. Pressure control is being maintained by RCIC and SRVs. Level control is being maintained with control rod drive (CRD) with level at 29.7 " (about 2 " below normal).
The licensee notified the NRC Resident Inspector. The Headquarters Operations Officer notified the R3DO (John Madera).
The licensee was performing preventative maintenance on electrical equipment when an error caused the loss of the '1B' 4160 volt non-vital bus. When the bus deenergized, two condensate pumps were lost resulting in loss of feed to the reactor. The operators manually scrammed the reactor, all rods fully inserted and the plant is stable in Mode 3 with level control from the balance of the condensate and feed system. Pressure control is by RCIC supplemented by SRVs as needed. The plant is continuing to Cold Shutdown and an investigation into the initiating event is pending.
A press release is planned by the licensee. The licensee has notified the local and state authorities as well as the NRC Resident Inspector.
* * * UPDATE AT 1547 EDT ON 5/17/00 BY VINCE PATTEN TO FANGIE JONES * * *
During the plant cooldown received a MSIV closure signal due to low vacuum as a result of breaking vacuum as a result of loss of seal steam to the main turbine.
RHR reject to radwaste, 1E12-F049, automatically isolated on a level 3 signal due to momentary reactor vessel level shrink from SRV operations.
The licensee is continuing to cooldown the plant. Pressure control is being maintained by RCIC and SRVs. Level control is being maintained with control rod drive (CRD) with level at 29.7 " (about 2 " below normal).
The licensee notified the NRC Resident Inspector. The Headquarters Operations Officer notified the R3DO (John Madera).