Skip to main content

Event Notification Report for May 06, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
05/05/2000 - 05/06/2000

EVENT NUMBERS
36977

Power Reactor
Event Number: 36977
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: NICK CONICELLA
HQ OPS Officer: BOB STRANSKY
Notification Date: 05/07/2000
Notification Time: 03:01 [ET]
Event Date: 05/06/2000
Event Time: 23:24 [EDT]
Last Update Date: 05/07/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
Person (Organization):
NIEL DELLA GRECA (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A N 0 Refueling 0 Refueling
Event Text
AUTOMATIC REACTOR SCRAM SIGNAL WITH ALL CONTROL RODS INSERTED AND UNIT DEFUELED

"At the time of the event, the Hope Creek reactor was in a preplanned outage with the core completely offloaded to the spent fuel pool, all control rods inserted, and the control rod drive hydraulic system isolated.

"Outage work required isolating air to the scram discharge volume vent and drain valves which resulted in these valves being closed. Water inleakage was identified to the scram discharge volume. Since there was no drain path, water level continued to rise in the discharge volume until the high scram discharge volume level scram signal was reached. No components repositioned as a result of the scram signal since they were already in their fail safe positions as a result of preplanned outage work.

"Based on the condition of the reactor, the control rod drive hydraulic system, and the reactor protection system at the time of the event, the validity of the ESF signal is being evaluated."

The licensee will inform the NRC resident inspector of this event.