Event Notification Report for April 29, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/28/2000 - 04/29/2000

EVENT NUMBERS
3694436945

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36944
Facility: PRAIRIE ISLAND
Region: 3     State: MN
Unit: [] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: BILL MATHER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/29/2000
Notification Time: 12:48 [ET]
Event Date: 04/29/2000
Event Time: 09:45 [CDT]
Last Update Date: 05/17/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
GARY SHEAR (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
DETERMINATION THAT DUAL INDICATION ON FEEDWATER CONTAINMENT ISOLATION VALVES (WHILE IN THE CLOSED POSITION) MAY RESULT IN THEM BEING DEGRADED

The following text is a portion of a facsimile received from the licensee:

"While shutting down [the] Unit 2 reactor for a refueling shutdown, leakage past the main feedwater control valves required shutting the feedwater containment isolation (CI) valves to [the] 21 and 22 steam generators (S/G) [in order] to maintain S/G level. With the CI valves in the closed position, the limit switch that provides a white status light on the containment isolation panel indicated the valves to be closed. The other limit [switches] that [provide] a red (open) and green (closed) indication for both valves were both on dual indication. S/G levels were controlled with the CI valves close. The dual indication on the CI valves while in the closed position may result in them being degraded. Containment integrity isolations per operation procedures [were] implemented. Further engineering evaluations and repairs will follow."

The licensee stated that a unit cooldown was in progress as part of a refueling outage which began shortly prior to midnight. (Refer to event #36942 for additional information.)

The licensee plans to notify the NRC resident inspector.

* * * RETRACTED AT 1530 EDT ON 5/17/00 BY ELLISON TO FANGIE JONES * * *

"Event Notification #36944 on April 29, 2000 documented a situation during unit cooldown where dual indication (both open and closed positions) on both feedwater containment isolation valves brought into doubt the actual position of the valves and their ability to perform their design bases functions. Further evaluation of the actual positions of the valves, their ability to stop flow, and their design bases functions led to the conclusion that the valves did meet the required functions at the time and were capable of meeting all design bases required functions. Therefore, Event Notification #36944 is being withdrawn."

The licensee will notify the NRC Resident Inspector. The Headquarters Operations Officer notified the R3DO (John Madera).


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36945
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: STEPHEN BAKER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/29/2000
Notification Time: 23:38 [ET]
Event Date: 04/29/2000
Event Time: 22:34 [EDT]
Last Update Date: 05/19/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
JAMES NOGGLE (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
UNEXPECTED ISOLATION OF CONTAINMENT PURGE

A containment purge valve closed due to a loss of power to a radiation monitor. The licensee stated that the cause was deenergization of the power panel per procedures for that radiation monitor.

Apparently, this was the first time this procedure had been performed since it had been revised, and there was no caution in the procedure indicating that if a purge is in effect, it would be secured. The licensee plans to change the procedures to reflect the possibility of isolation so that it can be isolated before the radiation monitor is deenergized.

The licensee notified the NRC resident inspector as well as state and local authorities.

* * * RETRACTION 1336 5/19/2000 FROM MYER TAKEN BY STRANSKY * * *

"On 4/29/00 a Containment Purge Valve Isolation signal (CPVIS) was generated due to a loss of power to a radiation monitor. The CPVIS automatically closed the Containment Purge system supply and exhaust valves. This condition was conservatively reported as an event that resulted in an automatic actuation of an Engineered Safety Feature (ESF).

"Subsequent investigation determined that the Containment Gaseous Radiation Monitor, RM-8123B, had been properly removed from service at 0801 on April 28, 2000 in accordance [with] the applicable Operating Procedure. The actuation signal from RM-8123B was the direct result of a planned loss of power to VA-30 and was not the result of a valid high radiation condition with the Containment. Therefore, the actuation signal was invalid.

"The actuation only involved the automatic closure of the supply and exhaust valves within the Containment Purge system. The Containment Purge system is equivalent to 'Reactor Building Ventilation System' as defined in IEEE Std 805-1984. Therefore, the Containment Purge system is equivalent to 'Reactor Building Ventilation System' identified in 10CFR50.72(b)(2)(ii).

"Section 10CFR50.72(b)(2)(ii) states that the licensee shall report any event or condition that resulted in a manual or automatic actuation of an Engineered Safety Feature (ESF) including the Reactor Protection System (RPS), except when:

"(B) The actuation was invalid and

" (1) Occurred while the system was properly removed from service (or),

" (2) Occurred after the safety function had been already completed or

" (3) Involved only the following specific ESFs or their equivalent systems
iii Reactor Building Ventilation system.

"Since the actuation was invalid and since the event occurred after the applicable sensor had been properly removed from service in accordance with approved plant procedures and the actuation involved only the Containment Purge system, a system which can be shown to be equivalent to the Engineered Safety Feature provided by the Reactor Building Ventilation system, this event is not reportable pursuant to either 10CFR50.72(b)(2)(ii)(B) or 10CFR50.73(a)(2)(iv)(B) and the Immediate Notification for this condition is retracted."

The NRC resident inspector has been informed of this retraction. Notified R1DO (Lew).