Event Notification Report for April 01, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/31/2000 - 04/01/2000
Power Reactor
Event Number: 36854
Facility: FERMI
Region: 3 State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: KEVIN DAHM
HQ OPS Officer: DOUG WEAVER
Region: 3 State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: KEVIN DAHM
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/01/2000
Notification Time: 22:28 [ET]
Event Date: 04/01/2000
Event Time: 19:15 [EST]
Last Update Date: 04/01/2000
Notification Time: 22:28 [ET]
Event Date: 04/01/2000
Event Time: 19:15 [EST]
Last Update Date: 04/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
Person (Organization):
RONALD GARDNER (R3)
RONALD GARDNER (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | M/R | Y | 23 | Power Operation | 0 | Hot Shutdown |
REACTOR SCRAM
On Saturday 4/1/2000, at 1200 hours, control room operators commenced a planned unit shutdown in preparation for refueling outage number 7. At 1815 hours, the 'A' Reactor Recirculation Pump exhibited speed fluctuations and was tripped. The crew conducted an evaluation to determine existing procedure guidance for operation at low power and low flow in a single loop configuration, and conservatively decided to shut down the reactor. At 1915 hours, the Reactor Operator placed the Reactor Mode Switch in Shutdown inserting a manual scram from 23% reactor power. All control rods fully inserted. All systems operated as expected, no safety/relief valves opened and no ECCS systems initiated/actuated.
The lowest reactor water level observed was 163 inches, normal operating band is 196 inches, all level three isolations (173 inches) came in as expected. At present, reactor water level is operating in normal operating band and is being maintained on the startup level control valve. No steam leaks noted.
The licensee notified the NRC resident inspector.
On Saturday 4/1/2000, at 1200 hours, control room operators commenced a planned unit shutdown in preparation for refueling outage number 7. At 1815 hours, the 'A' Reactor Recirculation Pump exhibited speed fluctuations and was tripped. The crew conducted an evaluation to determine existing procedure guidance for operation at low power and low flow in a single loop configuration, and conservatively decided to shut down the reactor. At 1915 hours, the Reactor Operator placed the Reactor Mode Switch in Shutdown inserting a manual scram from 23% reactor power. All control rods fully inserted. All systems operated as expected, no safety/relief valves opened and no ECCS systems initiated/actuated.
The lowest reactor water level observed was 163 inches, normal operating band is 196 inches, all level three isolations (173 inches) came in as expected. At present, reactor water level is operating in normal operating band and is being maintained on the startup level control valve. No steam leaks noted.
The licensee notified the NRC resident inspector.
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36852
Facility: FT CALHOUN
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: LARRY LEES
HQ OPS Officer: STEVE SANDIN
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: LARRY LEES
HQ OPS Officer: STEVE SANDIN
Notification Date: 04/01/2000
Notification Time: 11:02 [ET]
Event Date: 04/01/2000
Event Time: 09:20 [CST]
Last Update Date: 04/19/2000
Notification Time: 11:02 [ET]
Event Date: 04/01/2000
Event Time: 09:20 [CST]
Last Update Date: 04/19/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(i)(A) - PLANT S/D REQD BY TS
10 CFR Section:
50.72(b)(1)(i)(A) - PLANT S/D REQD BY TS
Person (Organization):
KRISS KENNEDY (R4)
KRISS KENNEDY (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Hot Standby | 0 | Hot Standby |
TECH SPEC REQUIRED SHUTDOWN DUE TO EMERGENCY FEEDWATER STORAGE TANK LEVEL DECREASING BELOW TECH SPEC LIMIT
THE PLANT ENTERED ABNORMAL OPERATING PROCEDURE (AOP) 30, "EMERGENCY FILL OF EMERGENCY FEEDWATER STORAGE TANK," AS A RESULT OF THE EMERGENCY FEEDWATER STORAGE TANK LEVEL FALLING BELOW TECH SPEC LOW LIMIT OF 91%. THIS RESULTED IN ENTRY INTO TECH SPEC 2.0.1 WHICH DIRECTS PLACING THE PLANT IN HOT SHUTDOWN WITHIN 6 HOURS, LESS THAN 300 DEGREES F IN ANOTHER 6 HOURS AND IN COLD SHUTDOWN IN 30 HOURS. AT THE TIME OF ENTRY INTO THIS TECH SPEC THE PLANT WAS ALREADY IN HOT SHUTDOWN. ACTIONS TO REFILL THE EMERGENCY FEEDWATER STORAGE TANK WERE TAKEN BY OPENING THE CONDENSATE FILL LINE AND EMERGENCY FILLING. FILLING WAS IN PROGRESS BEFORE GOING BELOW 91%, HOWEVER, SYSTEM DEMAND WAS GREATER THAN THE MAKEUP ABILITY OF THE DEMINERALIZED WATER SOURCE (STEAM GENERATOR WATER SUPPLY SWAPOVER). LEVEL WAS ABOVE 91% AT 0944CST AT WHICH TIME AOP 30 AND TECH SPEC 2.0.1 WERE EXITED.
THE LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR.
* * * UPDATE AT 1007 ON 4/19/00 BY MATZKE RECEIVED BY WEAVER * * * EVENT RETRACTION
On April 1, 2000, at 1102 EDT, Fort Calhoun Station made a 1-hour notification of entry into a shutdown-required Technical Specification Limiting Condition for Operation (LCO) to the NRC Operations Center under 10CFR50.72(b)(1)(i)(A). At the time the plant had completed a normal shutdown to hot standby per plant procedures. While maintaining the plant in Hot Standby (Mode 3), the indicated level in the Emergency Feedwater Storage Tank (EFWST), FW-19, appeared to fall below the Technical Specification (TS) minimum level of 55,000 gallons. Operators conservatively entered TS 2.0.1 (equivalent to standard TS 3.0.3). This LCO would have required the plant to be placed in Cold Shutdown (Mode 4). The tank level was quickly recovered and the TS exited. Subsequent investigation determined that the TS for EFWST level had not been violated and TS 2.0.1 not entered. Therefore, the notification of April 1, is being withdrawn.
The Resident Inspector was notified. Reg 4 RDO(Powers) was notified.
THE PLANT ENTERED ABNORMAL OPERATING PROCEDURE (AOP) 30, "EMERGENCY FILL OF EMERGENCY FEEDWATER STORAGE TANK," AS A RESULT OF THE EMERGENCY FEEDWATER STORAGE TANK LEVEL FALLING BELOW TECH SPEC LOW LIMIT OF 91%. THIS RESULTED IN ENTRY INTO TECH SPEC 2.0.1 WHICH DIRECTS PLACING THE PLANT IN HOT SHUTDOWN WITHIN 6 HOURS, LESS THAN 300 DEGREES F IN ANOTHER 6 HOURS AND IN COLD SHUTDOWN IN 30 HOURS. AT THE TIME OF ENTRY INTO THIS TECH SPEC THE PLANT WAS ALREADY IN HOT SHUTDOWN. ACTIONS TO REFILL THE EMERGENCY FEEDWATER STORAGE TANK WERE TAKEN BY OPENING THE CONDENSATE FILL LINE AND EMERGENCY FILLING. FILLING WAS IN PROGRESS BEFORE GOING BELOW 91%, HOWEVER, SYSTEM DEMAND WAS GREATER THAN THE MAKEUP ABILITY OF THE DEMINERALIZED WATER SOURCE (STEAM GENERATOR WATER SUPPLY SWAPOVER). LEVEL WAS ABOVE 91% AT 0944CST AT WHICH TIME AOP 30 AND TECH SPEC 2.0.1 WERE EXITED.
THE LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR.
* * * UPDATE AT 1007 ON 4/19/00 BY MATZKE RECEIVED BY WEAVER * * * EVENT RETRACTION
On April 1, 2000, at 1102 EDT, Fort Calhoun Station made a 1-hour notification of entry into a shutdown-required Technical Specification Limiting Condition for Operation (LCO) to the NRC Operations Center under 10CFR50.72(b)(1)(i)(A). At the time the plant had completed a normal shutdown to hot standby per plant procedures. While maintaining the plant in Hot Standby (Mode 3), the indicated level in the Emergency Feedwater Storage Tank (EFWST), FW-19, appeared to fall below the Technical Specification (TS) minimum level of 55,000 gallons. Operators conservatively entered TS 2.0.1 (equivalent to standard TS 3.0.3). This LCO would have required the plant to be placed in Cold Shutdown (Mode 4). The tank level was quickly recovered and the TS exited. Subsequent investigation determined that the TS for EFWST level had not been violated and TS 2.0.1 not entered. Therefore, the notification of April 1, is being withdrawn.
The Resident Inspector was notified. Reg 4 RDO(Powers) was notified.
Power Reactor
Event Number: 36853
Facility: FITZPATRICK
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: TOM PLUMPTON
HQ OPS Officer: DOUG WEAVER
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: TOM PLUMPTON
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/01/2000
Notification Time: 21:04 [ET]
Event Date: 04/01/2000
Event Time: 17:38 [EST]
Last Update Date: 04/01/2000
Notification Time: 21:04 [ET]
Event Date: 04/01/2000
Event Time: 17:38 [EST]
Last Update Date: 04/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
Person (Organization):
MICHELE EVANS (R1)
MICHELE EVANS (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | A/R | Y | 26 | Power Operation | 0 | Hot Shutdown |
REACTOR SCRAM
During a planned power reduction, the recombiner was removed from service. The recombiner bypass valve shut, reason unknown, isolating all off gas flow. Vacuum decayed as a result. The main turbine was manually tripped, followed by an automatic reactor scram.
Three rods did not indicate fully inserted immediately after the trip, but were later verified to be full in. The recirculating pumps are running and steam is being dumped to the main condenser (vacuum was restored) to remove decay heat.
The licensee informed the NRC resident inspector and will make a press release.
During a planned power reduction, the recombiner was removed from service. The recombiner bypass valve shut, reason unknown, isolating all off gas flow. Vacuum decayed as a result. The main turbine was manually tripped, followed by an automatic reactor scram.
Three rods did not indicate fully inserted immediately after the trip, but were later verified to be full in. The recirculating pumps are running and steam is being dumped to the main condenser (vacuum was restored) to remove decay heat.
The licensee informed the NRC resident inspector and will make a press release.