Event Notification Report for March 24, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/23/2000 - 03/24/2000

EVENT NUMBERS
36832368333682936830

Power Reactor
Event Number: 36832
Facility: GRAND GULF
Region: 4     State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: DAVID HANKS
HQ OPS Officer: FANGIE JONES
Notification Date: 03/24/2000
Notification Time: 12:58 [ET]
Event Date: 03/24/2000
Event Time: 11:30 [CST]
Last Update Date: 03/24/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - ENS INOPERABLE
Person (Organization):
LAWRENCE YANDELL (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
COMPLETE LOSS OF COMMERCIAL AND DEDICATED PHONE LINES

The plant has lost all normal offsite communications, commercial and FTS. This is an area problem, not just a plant problem. Bell South has been contacted and is troubleshooting the problem. The plant still has its communication link to load dispatch as well as radio communication. Also, the control room has a satellite phone which was used to make this notification.

The licensee notified the NRC Resident Inspector.

* * * UPDATE AT 2148 EST ON 3/24/00 BY CHRIS MILLER TO FANGIE JONES * * *

The FTS and commercial phones have been restored. The NRC Resident Inspector and R4DO (Lawrence Yandell) have been notified.


Power Reactor
Event Number: 36833
Facility: RIVER BEND
Region: 4     State: LA
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: DONALD CHASE
HQ OPS Officer: FANGIE JONES
Notification Date: 03/24/2000
Notification Time: 16:18 [ET]
Event Date: 03/24/2000
Event Time: 13:00 [CST]
Last Update Date: 03/24/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
LAWRENCE YANDELL (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
ONE EMERGENCY SIREN INADVERTENTLY INITIATED

"One (1) emergency siren inadvertently initiated on 03-24-00 at 1300. At 1310. the West Feliciana parish BOC Director called to advise RBS personnel that one of our sirens in East Feliciana parish had sounded. Telephone calls with East Feliciana personnel corroborated the information. Siren control computer records indicate that beginning at 1230, siren #6 had attempted unsuccessfully to power up several times. At 1300, it succeeded in powering up and sounded for about two minutes. There was no event or maintenance activity in progress to initiate this siren. The siren is communicating with the RBS LOF communications room but the siren was not initiated from that center. The cause of the activation is not known at this time. Technicians are en route to the siren to investigate. All other sirens are fully operable. The Louisiana Office of Emergency Preparedness (State Agency) and the RBS NRC site Senior Resident Inspector (T. Pruitt) have been notified."


Power Reactor
Event Number: 36829
Facility: SUSQUEHANNA
Region: 1     State: PA
Unit: [1] [] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAVE WALSH
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 03/24/2000
Notification Time: 05:56 [ET]
Event Date: 03/24/2000
Event Time: 04:45 [EST]
Last Update Date: 03/24/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
LOUIS MANNING (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
- 'C' INBOARD MAIN STEAM ISOLATION VALVE FAILED ITS LOCAL LEAK RATE TEST -

During the performance of a local leak rate test of the 'C' main steam isolation valves (MSIVs) with Unit 1 in a refueling outage, the inboard MSIV #HV141-F022C was unable to hold pressure. This constitutes a failure of the maximum path leak rate required by Tech Spec 3.6.1.3.

This condition constitutes a degraded condition of a principal safety barrier found while Unit 1 was shutdown. No other adverse conditions were identified.

Unit 1 remains safely shutdown and the licensee is conducting an investigation to determine the cause of the failure.

The licensee plans to notify the NRC Resident Inspector.


Power Reactor
Event Number: 36830
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: STEVE MYERS
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 03/24/2000
Notification Time: 06:32 [ET]
Event Date: 03/24/2000
Event Time: 05:37 [EST]
Last Update Date: 03/24/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
LOUIS MANNING (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 70 Power Operation
Event Text
- CONTROL ROD DROPPED INTO THE CORE DURING CONTROL ROD MOTION TESTING -

While performing control rod motion testing, plant technicians were checking the control rod fuses and caused a fuse to blow which caused control rod #48 to drop into the core. Plant operators reduced power from 100% to 70% and are in the process of retrieving the dropped control rod and are investigating the cause of the blown fuse.

The licensee notified state and local officials and the NRC Resident Inspector.