Event Notification Report for March 05, 2000
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/04/2000 - 03/05/2000
EVENT NUMBERS
36758
Power Reactor
Event Number: 36758
Facility: COOPER
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: STEVEN JOBE
HQ OPS Officer: LEIGH TROCINE
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: STEVEN JOBE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 03/06/2000
Notification Time: 02:39 [ET]
Event Date: 03/05/2000
Event Time: 22:00 [CST]
Last Update Date: 03/06/2000
Notification Time: 02:39 [ET]
Event Date: 03/05/2000
Event Time: 22:00 [CST]
Last Update Date: 03/06/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND 50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND 50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
CHARLES CAIN (R4)
CHARLES CAIN (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Hot Shutdown | 0 | Hot Shutdown |
FAILURE TO MEET DRYWELL-TO-SUPPRESSION CHAMBER LEAKAGE TEST ACCEPTANCE CRITERIA
The following text is a portion of a facsimile received from the licensee:
"The acceptance criteria specified for the DRYWELL-TO-SUPPRESSION CHAMBER LEAKAGE TEST was not met. The as-found value of 0.51 [inches] H2O/Min exceeded the operability value of <= 0.2 [inches] H2O/Min. Based on this, the operability of the drywell-to-suppression chamber vent pipes, vent header downcomers, and vacuum breakers cannot be assumed. Primary containment was declared inoperable based on a failure to meet the requirements of [surveillance requirement (SR)] 3.6.1.1.2, Verify drywell to suppression chamber bypass leakage is equivalent to a hole < 1.0 inch in diameter."
"[The unit] entered [limiting condition for operation (LCO)] 3.6.1.1, Condition A, requiring the restoration of primary containment to an operable status within 1 hour. If this required action is not met, Condition B.1 requires having the reactor in Mode 3 within 12 hours and B.2 requires having the reactor in Mode 4 within 36 hours."
"Currently[, the unit is] in Mode 3 for commencing [a] planned refueling outage."
"Engineering evaluation of test results is continuing, and the resident inspectors will be kept apprised."
The licensee notified the NRC resident inspectors.
The following text is a portion of a facsimile received from the licensee:
"The acceptance criteria specified for the DRYWELL-TO-SUPPRESSION CHAMBER LEAKAGE TEST was not met. The as-found value of 0.51 [inches] H2O/Min exceeded the operability value of <= 0.2 [inches] H2O/Min. Based on this, the operability of the drywell-to-suppression chamber vent pipes, vent header downcomers, and vacuum breakers cannot be assumed. Primary containment was declared inoperable based on a failure to meet the requirements of [surveillance requirement (SR)] 3.6.1.1.2, Verify drywell to suppression chamber bypass leakage is equivalent to a hole < 1.0 inch in diameter."
"[The unit] entered [limiting condition for operation (LCO)] 3.6.1.1, Condition A, requiring the restoration of primary containment to an operable status within 1 hour. If this required action is not met, Condition B.1 requires having the reactor in Mode 3 within 12 hours and B.2 requires having the reactor in Mode 4 within 36 hours."
"Currently[, the unit is] in Mode 3 for commencing [a] planned refueling outage."
"Engineering evaluation of test results is continuing, and the resident inspectors will be kept apprised."
The licensee notified the NRC resident inspectors.