Event Notification Report for February 04, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/03/2000 - 02/04/2000

EVENT NUMBERS
366593666036661366623666336704

Power Reactor
Event Number: 36659
Facility: MCGUIRE
Region: 2     State: NC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: W. SUSLICK
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/04/2000
Notification Time: 12:18 [ET]
Event Date: 02/04/2000
Event Time: 12:00 [EST]
Last Update Date: 02/04/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
KERRY LANDIS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 65 Power Operation 65 Power Operation
Event Text
LOW HEAD SAFETY INJECTION PUMPS SUCTION MAY SWAP FROM FWST CONTAINMENT SUMP BEFORE LOW FWST LEVEL IS REACHED.

"On February 4. 2000 during a review of engineering staff comments on a proposed technical specification change, a condition was discovered that may have resulted in operation outside the design basis of the plant. The specific condition is a deficiency in the current ACTION statement for McGuire Technical Specifications when invoked for one inoperable level channel of the refueling water storage tank (FWST). Currently this Technical Specification allows for the option of placing the affected channel in the trip condition, operation is permitted in this condition for an indefinite period of time.

"Because Technical Specifications allow operation in this condition for an indefinite period of time, this condition can not be considered a design basis single failure during a design basis accident. A single failure of an FWST level channel coincident with a design basis LOCA, with another channel in trip as allowed by technical specifications would result in premature swapover of the low head safety injection pumps to the containment sump. As a result of this premature swapover both trains of low head safety injection pumps could fail, which could result in a complete loss in recirculation phase post accident cooling.

"Currently all 3 channels of FWST level instrumentation of both McGuire Units are operable. Therefore, the plant is not operating with this single failure vulnerability. Administrative controls have been put into place to limit the time which the plant could operate in this condition until such time as Technical Specifications can be revised to limit this single failure vulnerability"

The NRC Resident Inspector was notified of this event by the licensee..


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36660
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: M VASELY
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/04/2000
Notification Time: 17:14 [ET]
Event Date: 02/04/2000
Event Time: 16:39 [EST]
Last Update Date: 03/03/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
TONY DIMITRIADIS (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 99 Power Operation 99 Power Operation
Event Text
VALIDITY OF ASSUMPTIONS FOR THE 30 MINUTE NITROGEN BACKUP SUPPLY IN QUESTION

During the review of Consolidated Edison calculation FIX-0030-02, Nitrogen Backup Supply for control of Auxiliary Feedwater Flow Control Valves, Turbine Driven Auxiliary Feedwater Pump, and Atmospheric Steam Dump Controls, questions arose as to the validity of the assumption statements that resulted in the design basis for 30 minutes of nitrogen could not be sustained. The assumptions are in the process of being validated. A third nitrogen bottle has been placed in backup alignment to maintain the 30 minute requirement.

3 of the 6 Nitrogen Backup Bottles are now valved in instead of 2.

The NRC Resident Inspector was notified of this event by the licensee.

* * * UPDATE AT 0936 ON 03/03/00 BY PHIL SANTINI TO JOLLIFFE * * *

Additional licensee engineering review has determined that the Nitrogen Backup Supply for control of Auxiliary Feedwater Flow Control Valves, Turbine Driven Auxiliary Feedwater Pump, and Atmospheric Steam Dump Controls does meet the design basis as documented in licensee calculation FIX-0030-02.

Thus, the licensee desires to retract this event.

The licensee notified the NRC Resident Inspector.

The NRC Operations Officer notified the R1DO Jim Trapp.


Power Reactor
Event Number: 36661
Facility: CLINTON
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT POWERS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/04/2000
Notification Time: 19:36 [ET]
Event Date: 02/04/2000
Event Time: 18:00 [CST]
Last Update Date: 02/04/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
TONY VEGEL (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 98 Power Operation 98 Power Operation
Event Text
SAFETY PARAMETER DISPLAY SYSTEM (SPDS) DECLARED INOPERABLE

AT 1042 CST SPDS WAS DECLARED INOPERABLE BECAUSE OF A HARDWARE PROBLEM WITH THEIR PLANT PROCESS COMPUTER WHICH FEEDS DATA INTO THE SPDS. THE LICENSEE HAS INCREASED MONITORING PLANT PARAMETERS. CARDS ARE BEING REPLACED IN THE PROCESS PLANT COMPUTER AT THIS TIME.

THE NRC RESIDENT INSPECTOR WAS INFORMED OF THIS EVENT BY THE LICENSEE.

* * * UPDATE AT 2143ET ON 02/04/00 BY HALVERSON TAKEN BY MACKINNON * * *

SPDS RETURNED TO SERVICE AT 1847CST. R3DO (VEGEL) NOTIFIED.

THE NRC RESIDENT INSPECTOR WILL BE NOTIFIED BY THE LICENSEE.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Fuel Cycle Facility
Event Number: 36662
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 3     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: ERIC WALKER
HQ OPS Officer: DOUG WEAVER
Notification Date: 02/05/2000
Notification Time: 08:42 [ET]
Event Date: 02/04/2000
Event Time: 20:00 [CST]
Last Update Date: 03/03/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2)(ii) - EQUIP DISABLED/FAILS
Person (Organization):
TONY VEGEL (R3)
JOE HOLONICH (NMSS)
Event Text
CRITICALITY ACCIDENT ALARM SYSTEM HORN FAILED SURVEILLANCE

At 1600 on 02-04-2000 the PSS was informed of the failure of a criticality accident alarm system (CAAS) air horn to sound during the performance of surveillance testing. The cause of the failure was determined to be debris in the air line fouling the flow path for the horn. Subsequently, after this horn was repaired and the air horn line blown out, another air horn on the same branch line became clogged and would not sound sufficiently. This horn was also repaired and its line blown out. The system was retested satisfactorily and declared operable at 2245 on 02-04-00. It is possible that the system would not have performed its intended safety function if it had been required to before it was declared inoperable.

This event is reportable under 10 CFR 76.120(c)(2) as an event in which equipment required by the TSR is disabled or fails to function as designed.

The NRC Senior Resident Inspector has been notified of this event.

* * * UPDATE ON 3/3/00 @ 1732 BY WALKER TO GOULD * * * RETRACTION

THIS EVENT HAS BEEN RETRACTED. Subsequent testing of the C-337A CAAS horn system with the subject horn valved out, has shown that the CAAS meets the requirements for audibility in this area without this horn. Engineering Evaluation EV-C-812-00-003 Rev. 0 was completed to document the conclusions of this testing.

The NRC Resident inspector was informed.

The Reg 3 RDO(Jordan) and NMSS EO(Sherr) were notified.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36663
Facility: SOUTH TEXAS
Region: 4     State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GREG JANAK
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/05/2000
Notification Time: 13:54 [ET]
Event Date: 02/04/2000
Event Time: 20:59 [CST]
Last Update Date: 02/17/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CLAUDE JOHNSON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
2 TRAINS OF ESSENTIAL CHILLED WATER INOPERABLE

On 02/04/00 at 2059 CST, Essential Chiller 12C was declared inoperable due to tripping after being started at 2056 CST on 02/04/00. This resulted in an entry into Technical Specification 3.7.14. Investigation revealed that Essential Chiller 12C tripped on high condenser pressure which was caused by not having cooling water flow properly aligned. Found Essential Cooling Water valve EVV-3025 to be closed, when it's required position is throttled to maintain Essential Cooling Water flow. The valve alignment was restored to normal and Essential Chiller 12C was declared operable at 2358 CST on 02/04/00.

The investigation revealed that EVV-3025 was closed at approximately 1121 CST on 02/02/00 as indicated on integrated computer system trends. At that time Essential Chilled Water Train "B" was inoperable for planned maintenance and remained inoperable until 1527 CST on 02/02/00. This resulted in 2 trains of Essential Chilled Water being inoperable for 4 hours and 6 minutes which placed the plant in Technical Specification 3.0.3 (did not require plant shutdown).

A Licensee Event Report will be submitted within 30 days.

The NRC Resident Inspector was notified of this event by the licensee.

* * * UPDATE AT 1708 ON 2/17/00, BY MORRIS RECEIVED BY WEAVER * * *

Upon further evaluation, it has been determined that Train 'B' of Essential Chilled Water was operable prior to the point in time when Train 'C' of Essential Chilled Water was rendered inoperable, and thus the event is not reportable and therefore should be retracted.

Following maintenance, at 0814 CST hours on February 2, 2000, the 12B Essential Chiller was placed in service, and at 1100 CST hours post-maintenance testing was completed. Also by this time, the 'B' Train of Essential Cooling Water and the #12 ESF Diesel Generator had already been declared operable. Additionally, although post-maintenance testing was not signed-off as complete until 1237 CST hours for the 'B' Train Essential Chilled Water air handling unit, the unit was in service and the post-maintenance testing (completed at approximately 1014 CST hours) verified that the air handling unit had been capable of performing its function since the completion of its associated maintenance work. In summary, although the 12B Essential Chiller was not administratively considered operable until 1527 CST hours on February 2, 2000, following final paperwork close-out, it was fully capable of performing its intended design function at 1100 CST hours.

Thus, when the 12C Essential Chiller was rendered inoperable at 1121 CST hours, the 'B' train of Essential Chilled Water (including necessary support equipment) was fully capable of performing its design function (i.e.. operable). Since the 'B' train of Essential Chilled Water was therefore operable when the 'C' train was made inoperable, only one train of Essential Chilled Water was inoperable at a time, and Technical Specification 3.0.3 was not entered.

The licensee informed the NRC resident inspector of this event retraction. The Operations Center notified the R4DO(Tapia).


Other Nuclear Material
Event Number: 36704
Rep Org: NC DIVISION OF RADIATION PROTECTION
Licensee: FROELING & ROBERTSON, INC.
Region: 2
City: RALEIGH   State: NC
County:
License #: 092-0353-6
Agreement: Y
Docket:
NRC Notified By: J. MARION EADDY
HQ OPS Officer: BOB STRANSKY
Notification Date: 02/17/2000
Notification Time: 10:55 [ET]
Event Date: 02/04/2000
Event Time: 00:00 [EST]
Last Update Date: 02/17/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
KENNETH BARR (R2)
JOHN HICKEY (NMSS)
Event Text
TROXLER MOISTURE DENSITY GAUGE LOST DURING SHIPPING

The following information was submitted by the State of North Carolina via facsimile:

"Froeling & Robertson, Inc (F&R). (N.C. License No. 092-0353.6) shipped one Troxler Model 3411-B nuclear gauge (s/n 9220) from the Raleigh, NC office to their Chesapeake, VA. Office (NRC License No. 45-08890-02) on 04 February 2000 via FedEx. As of today's date, the gauge has not been delivered to the Chesapeake office.

"FedEx is conducting a search of the Raleigh, NC, hub, as well as tracking the package at other FedEx hubs in the area. F&R has notified all of its branch offices of the occurrence.

"North Carolina has assigned log number ICD-00-03 to this incident."

*************** UPDATE AT 1341 ON 02/17/00 FROM J. MARION EADDY TO LEIGH TROCINE ***************

The following text is a portion of a facsimile received from the North Carolina Division of Radiation Protection:

"UPDATE on Loss of a Troxler Model 3411-B Moisture/Density Gauge NC Log No. ICD-00-03."

"[The] North Carolina Division of Radiation Protection received a call from the Radiation Safety Officer for FedEx this afternoon. The gauge (Troxler Model 3411-B s/n 9220) was located at Troxler Electronic Laboratories Research Triangle Park Office."

"North Carolina is continuing to investigate this incident."

The NRC operations officer notified the R2DO (Barr) and NMSS EO (Piccone).

Call the NRC operations officer for a contact telephone number