Event Notification Report for February 02, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
02/01/2000 - 02/02/2000

EVENT NUMBERS
36653366543665536702

Power Reactor
Event Number: 36653
Facility: WNP-2
Region: 4     State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: HEDGES
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 02/02/2000
Notification Time: 14:51 [ET]
Event Date: 02/02/2000
Event Time: 11:34 [PST]
Last Update Date: 02/02/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
CLAUDE JOHNSON (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
LICENSEE DISCOVERED A CONDITION THAT IS OUTSIDE THE PLANT DESIGN BASIS

At 1134 PST on 02/02/00, after discussions with General Electric Company representatives, the licensee determined that the condition described below was not known to be previously analyzed and was outside the design basis of the plant and was reportable to the NRC. The plant remains in Condition 1 at 100% power with the condition yielding primary containment and reactor coolant pressure boundary OPERABLE but nonconforming in accordance with NRC Generic Letter 91-18, Revision 1.

The WNP-2 UFSAR Section 7.4.1.1.2 and TMI response ll.K.1.22 state that the Reactor Core Isolation Cooling (RCIC) System is designed to automatically start if reactor water level decreases to the low level signal setpoint (level 2), automatically stop at the high water level signal setpoint (level 8), and restart if water level decreases again to low level signal setpoint (level 2). The RCIC System is equipped with a "Keep-Fill" pump designed to maintain the RCIC System full. However, the RCIC Keep-Fill pump is not single failure proof. Therefore, during accident or transient scenarios which include a sufficient decrease in reactor vessel water level, restart of the RCIC System in conjunction with a failure of the Keep-Fill pump, could create a water hammer in the RCIC System piping and potentially jeopardize the integrity of the reactor coolant pressure boundary (RCPB) or primary containment (PC) isolation barriers associated with the RCIC System.

An operability assessment has determined that the RCPB and PC are OPERABLE but nonconforming to single failure criteria, crediting existing proceduralized operator actions. The RCIC System is equipped with low pressure alarm annunciation in the main control room. To prevent water hammer, plant procedures require operator action to inhibit RCIC pump starts (except as directed by emergency operating procedures) upon receipt of this low pressure alarm.

WNP-2 is continuing to evaluate the significance of this postulated scenario through engineering analysis.

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 36654
Facility: LIMERICK
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: MARK SCHWIKER
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 02/02/2000
Notification Time: 23:50 [ET]
Event Date: 02/02/2000
Event Time: 23:00 [EST]
Last Update Date: 02/02/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
TONY DIMITRIADIS (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
- LONG TERM ADS BACKUP NITROGEN SUPPLY HEADER MANUAL BLOCK VALVES FOUND CLOSED -

At 2105 on 02/02/00, a plant operator found one manual block valve to each Long Term Automatic Depressurization System (ADS) backup nitrogen supply header isolated. This would have prevented Unit 2's ability to establish long term alternate decay heat removal capability in accordance with the plant design basis. Tech Spec 3.5.1.d requires Unit 2 to be placed in hot shutdown condition within 12 hours with these valves closed.

At 2125 on 02/02/00, plant operators opened both ADS manual block valves reestablishing long term backup nitrogen supply to the ADS valves and exited Tech Spec 3.5.1.d.

Normal ADS nitrogen supply header pressure was present with these valves in the closed position.

The licensee is investigating the cause of these valves being in the closed position.

At 2300 on 02/02/00, the licensee determined that this event was reportable to the NRC.

The licensee notified the NRC Resident Inspector.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Hospital
Event Number: 36655
Rep Org: ALLEGHENY VALLEY HOSPITAL
Licensee: ALLEGHENY VALLEY HOSPITAL
Region: 1
City: Natronia Heights   State: PA
County: Allegheny
License #: 37-002584-01
Agreement: N
Docket:
NRC Notified By: FRANK PTTINON
HQ OPS Officer: JOHN MacKINNON
Notification Date: 02/03/2000
Notification Time: 14:55 [ET]
Event Date: 02/02/2000
Event Time: 15:30 [EST]
Last Update Date: 02/03/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
35.33 - MED MISADMINISTRATION
Person (Organization):
TONY DIMITRIADIS (R1)
JOSIE PICCONE (NMSS)
Event Text
INCORRECT PATIENT GIVEN TECHNETIUM-99M FOR HDP BONE SCAN

A medical technician went to room 113 on 1A level and read the patient name plate on the wall outside the room before entering the room. The medical technician entered the room and addressed the elderly patient by the name that was labeled outside her room. The patient responded by saying yes that was her name. The medical technician injected the patient with 22 millicuries of technetium-99m HDP bone scanning agent. When the medical technician reviewed the patient label chart she discovered that she had given the technetium-99m HDP bone scanning agent to the incorrect patient. The correct patient had been taken downstairs for the technetium-99m injection. The patient and her physician were notified of the error. No harm will come to the patient because of the error.

* * * RETRACTION ON 02/03/00 AT 1635 HOURS BY FRANK OTTINON TAKEN BY MACKINNON * * *

This event is being retracted because the patient did not receive 5 rems effective dose equivalent or 50 rems dose equivalent to any individual organ as a result of receiving the accidental dose of 22 millicuries of technetium-99m as specified in 10 CFR 35.2 item (6) (ii).

NRC R1DO (Tony Dimitriadis) and NMSS EO (Joe Holonich) notified.


Other Nuclear Material
Event Number: 36702
Rep Org: U.S. ARMY
Licensee: U.S. ARMY
Region: 2
City: CAMP LE JEUNE   State: NC
County:
License #: 12-00722-06
Agreement: Y
Docket:
NRC Notified By: JEFF HAVENNER
HQ OPS Officer: BOB STRANSKY
Notification Date: 02/17/2000
Notification Time: 09:48 [ET]
Event Date: 02/02/2000
Event Time: 00:00 [EST]
Last Update Date: 02/17/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
BRUCE JORGENSEN (R3)
SCOTT MOORE (NMSS)
KENNETH BARR (R2)
Event Text
LOSS OF SEALED SOURCE CONTAINING 30 mCi OF TRITIUM

The licensee reported the loss of a small tritium source from a mortar system assigned to the U.S. Marine Corps School of Infantry at Camp Le Jeune, NC. A scale index lamp (a plastic arrow containing 30 mCi of tritium) became detached from an M-64 mortar sight unit while the mortar unit was being used on a firing range. The source was discovered to be missing after the unit had been moved from the firing range. The licensee stated that the source could not be located. This source poses no threat to the public as access to the firing range is controlled.