Skip to main content

Event Notification Report for January 18, 2000

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
01/17/2000 - 01/18/2000

EVENT NUMBERS
3660736601366023660336649

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36607
Facility: ZION
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: R. T. THORTON
HQ OPS Officer: LEIGH TROCINE
Notification Date: 01/18/2000
Notification Time: 19:15 [ET]
Event Date: 01/18/2000
Event Time: 18:02 [CST]
Last Update Date: 01/27/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
DAVID HILLS (R3)
ROBERTA WARREN (IAT)
JIM CREED (IAT)
JIM BELANGER (IAT)
DICK ROSANO (IAT)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Decommissioned 0 Decommissioned
2 N N 0 Decommissioned 0 Decommissioned
Event Text
SECURITY REPORT

UNSUBSTANTIATED BOMB THREAT. COMPENSATORY MEASURES TAKEN. LICENSEE INFORMED THE LOCAL POLICE DEPARTMENT.

* * * RETRACTION 1533 1/27/2000 FROM NOLDEN TAKEN BY STRANSKY * * *

After review of NRC Regulatory Guide 5.62, the licensee has determined that this event was not reportable. Notified R3DO (Phillips).


Power Reactor
Event Number: 36601
Facility: PALO VERDE
Region: 4     State: AZ
Unit: [1] [2] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: DAN MARKS
HQ OPS Officer: BOB STRANSKY
Notification Date: 01/18/2000
Notification Time: 11:41 [ET]
Event Date: 01/18/2000
Event Time: 09:25 [MST]
Last Update Date: 01/19/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - ENS INOPERABLE
Person (Organization):
LINDA SMITH (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF COMMERCIAL TELEPHONE SERVICE

The licensee reported that all U.S. West commercial telephone service to the site (including the ENS) has been lost due to a problem offsite. The licensee is attempting to contact U.S. West to determine the cause of the problem and estimate time to restore.

The NRC resident inspector will be informed of this event by the licensee.

******************** UPDATE AT 1916 ON 01/18/00 FROM DAN MARKS TO LEIGH TROCINE ********************

The following text is a portion of a facsimile received from the licensee:

"The following event description is based on information currently available. If through subsequent reviews of this event, additional information is identified that is pertinent to this event or alters the information being provided at this time, a followup notification will be made via the ENS or under the reporting requirements of 10 CFR 50.73."

"NOTE: THIS ENS WORKSHEET IS A FOLLOW-UP TO ENS ID 36601, PERFORMED AT 09:41 MST. SINCE U.S. WEST LINES WERE AFFECTED, THE INITIAL CALL WAS MADE VIA A CELLULAR TELEPHONE."

"On January 18, 2000, at approximately 0925 MST, Palo Verde Units 1, 2, and 3 determined that the ENS telephones were inoperable. This was related to the offsite damage to a 200-pair telecommunications cable affecting Palo Verde. The initial call was placed from the Nuclear Regulatory Affairs Director's cellular telephone, and that phone number was also provided to the [headquarters operations officer] if followup was necessary prior to restoration of the ENS."

"The current prognosis for full restoration of the ENS is approximately 2400 MST. If the Palo Verde Units 1, 2, or 3 cannot be reached via the ENS, [commercial] ... phone numbers are available. [Call the NRC operations officer for site contact numbers.] ..."

"Emergency Plan notification system backups for communication with State and County agencies were confirmed to remain operable; therefore, this notification was only for the loss of ENS and did not reflect a loss of emergency assessment or notification capability."

"There is no corresponding 10 CFR 50.73 reporting requirement. Palo Verde does not expect to followup this report with a Licensee Event Report (LER)."

"Palo Verde [plans to] complete a followup notification when full capability is restored."

The licensee notified the NRC resident inspector. The NRC operations officer notified the R4DO (Smith).

* * * UPDATE 0006EST ON 1/19/2000 FROM BRAD ROBINSON TO S.SANDIN * * *

The ENS phones have been restored to complete functionality at 2206MST. The licensee notified the NRC resident inspector. Notified R4DO(Smith).


Power Reactor
Event Number: 36602
Facility: SEQUOYAH
Region: 2     State: TN
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DAVID PORTER
HQ OPS Officer: FANGIE JONES
Notification Date: 01/18/2000
Notification Time: 11:40 [ET]
Event Date: 01/18/2000
Event Time: 10:51 [EST]
Last Update Date: 01/18/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(iv) - ECCS INJECTION 50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
ROBERT HAAG (R2)
JIM LYONS (NRR)
CHARLES MILLER (IRO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Standby
Event Text
INADVERTENT SAFETY INJECTION DUE TO ELECTRICAL FAULT AND REACTOR TRIP

Technicians were performing a modification to the vital inverter 2-IV when a safety injection signal was generated due to an electrical problem on vital instrument bus 2-IV. When the technicians were lifting a lead on the sync signal input to the inverter 2-IV in accordance with the modification, an inadvertent safety injection signal was generated. When the safety injection actuated, only Train 'A' safety injection occurred. The cause of the reactor trip is unknown at this time though it is expected with a safety injection. The operators followed the emergency procedures and started the Train 'B' safety injection and residual heat removal pumps; the train 'B' centrifugal charging pump started automatically (reason unknown and being investigated). The 2A-A motor-driven auxiliary feedwater pump tripped for unknown reasons. The #2 steam generator atmospheric relief valve controller appears to have failed, which required operators to take manual control and close the relief valve. An event investigation has been initiated, and all problems will be answered before the unit is restarted.

The plant is currently stable in Mode 3 with heat removal via the atmospheric reliefs and feedwater via the 2B-B motor-driven and turbine-driven auxiliary feedwater pumps. All rods fully inserted. The safety injection signal was from the 'Low Steam Generator Pressure' section, and the main steam isolation valves closed automatically. The plant has no steam generator tube leaks.

The licensee notified the NRC Resident Inspector.


General Information or Other
Event Number: 36603
Rep Org: UTAH DIVISION OF RADIATION CONTROL
Licensee: NUCLEAR TESTING SERVICES
Region: 4
City: SALT LAKE CITY   State: UT
County:
License #: UT 1800139
Agreement: Y
Docket:
NRC Notified By: JULIE FELICE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 01/18/2000
Notification Time: 17:41 [ET]
Event Date: 01/18/2000
Event Time: 10:00 [MST]
Last Update Date: 03/07/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
LINDA SMITH (R4)
WAYNE HODGES (NMSS)
JOSEPH GIITTER (IRO)
Event Text
AGREEMENT STATE REPORT INVOLVING TROXLER DENSITY GAUGE MISSING FROM NUCLEAR TESTING SERVICES LOCATED IN SALT LAKE CITY, UTAH

At 1000 MST on 01/18/00, Nuclear Testing Services located in Salt Lake City notified the Utah Division of Radiation Control of a lost, missing, or stolen gauge (Utah Incident Report UT-00-0002). The missing gauge was a Troxler Electronic Laboratories, Inc. gauge (model number 3430, gauge serial number 20882). The gauge contained two sealed sources: cesium-137 ( source serial number 7-2293) and americium-241/beryllium (source serial number 47-16381). Apparently, the licensee last had possession of the gauge during April of 1999. This was also when the last leak test was performed. The licensee believes that the gauge may have been leased out to another company during August of 1999. However, there may have been problems with the paperwork or accountability, and there were also changes in personnel.

The Utah Division of Radiation Control instructed the licensee to contact local Police Department because there is the possibility of theft. It was also reported that the licensee had been in touch with Troxler.

The Utah Division of Radiation Control stated that this event seemed to fit the Abnormal Occurrence Criteria under any substantial breakdown of physical security or material control. It was stated that one of those deals with accountability systems.

(Call the NRC operations center for a state contact telephone number.)

* * * UPDATE AT 1608 ON 03/07/00 BY JULIE FELICE TO JOLLIFFE * * *

Representatives from Geomatrix Consultants, Inc,, Costa Mesa, CA, notified representatives of Nuclear Testing Services, Salt Lake City, UT that the missing Troxler Moisture Density Gauge, Model #3430, Serial #20882, is in Geomatrix's possession and had been all along. Geomatrix representatives plan to return the undamaged gauge to Nuclear Testing Services.

The NRC Operations Officer notified the R4DO Dave Loveless and NMSS EO Scott Moore.


General Information or Other
Event Number: 36649
Rep Org: TEXAS BUREAU OF RAD CONTROL
Licensee: TECHNICAL WELDING LABORATORY INC
Region: 4
City: PASADENA   State: TX
County:
License #: L02187
Agreement: Y
Docket:
NRC Notified By: TIM HOPKINS (by fax)
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 02/01/2000
Notification Time: 17:42 [ET]
Event Date: 01/18/2000
Event Time: 00:00 [CST]
Last Update Date: 02/01/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2202(b)(1) - PERS OVEREXPOSURE/TEDE >= 5 REM
Person (Organization):
CLAUDE JOHNSON (R4)
JOE HOLONICH (NMSS)
FRANK CONGEL (IRO)
Event Text
TEXAS INCIDENT #7568 - RADIOGRAPHER RECEIVED A 1999 ANNUAL EXPOSURE OF 5.01 REM

On 01/18/00 the licensee received its film badge report from Atomic Energy Industrial Laboratory showing that an employee had exceeded the allowable occupational dose limit of 5 rems for the year ending 12/31/99. In following the Technical Welding Laboratory (TWL) radiation safety program and their operating and emergency procedures, the employee was notified of his exposure. In addition, he was brought into the office and reviewed TWL's ALARA program to ensure that he understands his responsibilities according to Texas State regulations and TWL's operating and emergency procedures.

After interviewing the employee and listening to his explanation of possible causes for the amount of radiation he received, it was determined that the employee needs to pay more attention to ALARA concerns in the future.