Event Notification Report for December 31, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/30/1999 - 12/31/1999
Power Reactor
Event Number: 36553
Facility: LIMERICK
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DOUG AMTSFIELD
HQ OPS Officer: DOUG WEAVER
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DOUG AMTSFIELD
HQ OPS Officer: DOUG WEAVER
Notification Date: 12/31/1999
Notification Time: 03:11 [ET]
Event Date: 12/31/1999
Event Time: 01:11 [EST]
Last Update Date: 12/31/1999
Notification Time: 03:11 [ET]
Event Date: 12/31/1999
Event Time: 01:11 [EST]
Last Update Date: 12/31/1999
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED 50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED 50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
RANDY BLOUGH (R1)
RICHARD WESSMAN (NRR)
JOSEPH GIITTER (IRO)
KEN CYBOCH (FEMA)
RANDY BLOUGH (R1)
RICHARD WESSMAN (NRR)
JOSEPH GIITTER (IRO)
KEN CYBOCH (FEMA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | A/R | Y | 100 | Power Operation | 0 | Hot Standby |
UNUSUAL EVENT - MAIN TRANSFORMER FAILURE
A main transformer insulator failure led to a catastrophic failure of the main transformer. This in turn led to a turbine trip and reactor scram. The plant response to the transient was normal and the plant is now stable in mode 3. Decay heat is being removed by dumping steam to the main condenser. Reactor vessel water level is being maintained by the condensate and feed systems. Offsite power was maintained throughout the event and no safety related equipment has been damaged. The event occurred at 0111 and the Unusual Event was declared at 0255. The Reactor Recirculation Pump EOC-RPT (End of Cycle Recirc Pump Trip) breakers tripped as expected due to the turbine stop valve and turbine control valve closures.
The unusual event was declared because of the potential impact of the failure on other plant components in the vicinity of the transformer. The licensee has notified the resident inspector.
* * * UPDATE AT 0431 ON 12/31/99 BY AMTSFIELD, RECEIVED BY WEAVER * * *
The unusual event was terminated at 0400. Damage was limited to the main transformer phase 'B' insulator with only ancillary damage to surrounding equipment and no damage to safety related equipment. The licensee has notified state and local governments of the event and a press release will be issued.
The operations center notified R1 (Blough); IRO (Giitter); EO (Wessman); FEMA (CYBOCH)
A main transformer insulator failure led to a catastrophic failure of the main transformer. This in turn led to a turbine trip and reactor scram. The plant response to the transient was normal and the plant is now stable in mode 3. Decay heat is being removed by dumping steam to the main condenser. Reactor vessel water level is being maintained by the condensate and feed systems. Offsite power was maintained throughout the event and no safety related equipment has been damaged. The event occurred at 0111 and the Unusual Event was declared at 0255. The Reactor Recirculation Pump EOC-RPT (End of Cycle Recirc Pump Trip) breakers tripped as expected due to the turbine stop valve and turbine control valve closures.
The unusual event was declared because of the potential impact of the failure on other plant components in the vicinity of the transformer. The licensee has notified the resident inspector.
* * * UPDATE AT 0431 ON 12/31/99 BY AMTSFIELD, RECEIVED BY WEAVER * * *
The unusual event was terminated at 0400. Damage was limited to the main transformer phase 'B' insulator with only ancillary damage to surrounding equipment and no damage to safety related equipment. The licensee has notified state and local governments of the event and a press release will be issued.
The operations center notified R1 (Blough); IRO (Giitter); EO (Wessman); FEMA (CYBOCH)
Power Reactor
Event Number: 36554
Facility: THREE MILE ISLAND
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: MARK JANES
HQ OPS Officer: DOUG WEAVER
Region: 1 State: PA
Unit: [1] [] []
RX Type: [1] B&W-L-LP,[2] B&W-L-LP
NRC Notified By: MARK JANES
HQ OPS Officer: DOUG WEAVER
Notification Date: 12/31/1999
Notification Time: 11:09 [ET]
Event Date: 12/31/1999
Event Time: 00:00 [EST]
Last Update Date: 12/31/1999
Notification Time: 11:09 [ET]
Event Date: 12/31/1999
Event Time: 00:00 [EST]
Last Update Date: 12/31/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
ROBERT SUMMERS (R1)
JOHN DAVIDSON (NMSS)
RICHARD ROSANO (NRR)
JOHN WHITE (R1)
ROBERT SUMMERS (R1)
JOHN DAVIDSON (NMSS)
RICHARD ROSANO (NRR)
JOHN WHITE (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
NON-CREDIBLE BOMB THREAT.
CONTACT THE NRC OPERATIONS CENTER FOR ADDITIONAL DETAILS.
LICENSEE WILL NOTIFY THE NRC RESIDENT.
CONTACT THE NRC OPERATIONS CENTER FOR ADDITIONAL DETAILS.
LICENSEE WILL NOTIFY THE NRC RESIDENT.
Power Reactor
Event Number: 36555
Facility: DUANE ARNOLD
Region: 3 State: IA
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: BRUCE ROWLAND
HQ OPS Officer: DICK JOLLIFFE
Region: 3 State: IA
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: BRUCE ROWLAND
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 12/31/1999
Notification Time: 13:13 [ET]
Event Date: 12/31/1999
Event Time: 11:33 [CST]
Last Update Date: 12/31/1999
Notification Time: 13:13 [ET]
Event Date: 12/31/1999
Event Time: 11:33 [CST]
Last Update Date: 12/31/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
BRUCE BURGESS (R3)
BRUCE BURGESS (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
PHYSICAL SECURITY EVENT -
MINIMUM SECURITY PERSONNEL STAFFING REQUIREMENTS NOT MET FOR 22 MINUTES. COMPENSATORY MEASURES IMMEDIATELY TAKEN UPON DISCOVERY. THE LICENSEE PLANS TO NOTIFY THE NRC RESIDENT INSPECTOR. CONTACT THE NRC OPERATIONS OFFICER FOR ADDITIONAL DETAILS.
MINIMUM SECURITY PERSONNEL STAFFING REQUIREMENTS NOT MET FOR 22 MINUTES. COMPENSATORY MEASURES IMMEDIATELY TAKEN UPON DISCOVERY. THE LICENSEE PLANS TO NOTIFY THE NRC RESIDENT INSPECTOR. CONTACT THE NRC OPERATIONS OFFICER FOR ADDITIONAL DETAILS.