Event Notification Report for December 19, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/18/1999 - 12/19/1999
EVENT NUMBERS
36560
General Information or Other
Event Number: 36560
Rep Org: WASHINGTON DEPARTMENT OF HEALTH
Licensee: INSPECTION SERVICE INC.
Region: 4
City: PASCO State: WA
County:
License #: WN-IR064-1
Agreement: Y
Docket:
NRC Notified By: TERRY FRAZEE
HQ OPS Officer: FANGIE JONES
Licensee: INSPECTION SERVICE INC.
Region: 4
City: PASCO State: WA
County:
License #: WN-IR064-1
Agreement: Y
Docket:
NRC Notified By: TERRY FRAZEE
HQ OPS Officer: FANGIE JONES
Notification Date: 01/04/2000
Notification Time: 10:40 [ET]
Event Date: 12/19/1999
Event Time: 00:00 [PST]
Last Update Date: 01/04/2000
Notification Time: 10:40 [ET]
Event Date: 12/19/1999
Event Time: 00:00 [PST]
Last Update Date: 01/04/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2)(ii) - EQUIP DISABLED/FAILS
10 CFR Section:
30.50(b)(2)(ii) - EQUIP DISABLED/FAILS
Person (Organization):
CHARLES CAIN (R4)
BRIAN SMITH (NMSS)
CHARLES CAIN (R4)
BRIAN SMITH (NMSS)
AGREEMENT STATE REPORT - INDUSTRIAL RADIOGRAPHY CAMERA AUTO-LOCKING MECHANISM FAILED
THIS EVENT WAS E-MAILED TO THE HEADQUARTERS OPERATION CENTER
"This is notification of an event in Washington state as reported to the WA Department of Health, Division of Radiation Protection.
STATUS: new
Licensee: Inspection Service Inc.
City and state: Kennewick, WA
License number: WN-IR064-1
Type of license: Industrial Radiography
Date of event: December 19, 1999
Location of Event: Pasco, WA
ABSTRACT: The auto-locking mechanism malfunctioned on an INC model IR 100 industrial radiography camera containing approximately 25 Curies of Ir-192. The malfunction was detected during the radiographer's survey of the circumference of the camera following the completion of a shot when approximately 500 mRem per hour was noted at the exit port of the camera.
Upon cranking in the source, the radiographer had observed the "plunger" drop into position indicating the source had been fully retracted and the auto-locking mechanism engaged. Upon reaching the camera the radiographer key-locked the camera while initiating the required circumference survey. Once locked, the key could not be moved to unlock the camera. The radiographer discovered that the source was not fully shielded and was not locked in place. The camera could not be unlocked to crank the source the extra one eighth turn needed to fully shield the source although it could be cranked out. The manufacturer was contacted and a procedure obtained for by-passing the locking mechanism. The licensee was told by the manufacturer that this type of event is 'extremely rare but it does happen'.
Using the procedure supplied by the manufacturer, the licensee was able to remove the locking assembly, free the key lock, re-set the auto-lock, re-assemble the mechanism and retract the source into its fully shielded
position. No unusual exposures were received by any personnel involved during this event or the successful completion of this operation.
What is the notification or reporting criteria involved? Equipment malfunction: inability to retract source to fully shielded position and secure it in this position.
Activity and isotope(s) involved: 25 curies of Ir-192
Overexposures? NONE
Device (HDR, etc.) Mfg., Model; computer code: I.N.C. model IR 100, serial number 4495"
THIS EVENT WAS E-MAILED TO THE HEADQUARTERS OPERATION CENTER
"This is notification of an event in Washington state as reported to the WA Department of Health, Division of Radiation Protection.
STATUS: new
Licensee: Inspection Service Inc.
City and state: Kennewick, WA
License number: WN-IR064-1
Type of license: Industrial Radiography
Date of event: December 19, 1999
Location of Event: Pasco, WA
ABSTRACT: The auto-locking mechanism malfunctioned on an INC model IR 100 industrial radiography camera containing approximately 25 Curies of Ir-192. The malfunction was detected during the radiographer's survey of the circumference of the camera following the completion of a shot when approximately 500 mRem per hour was noted at the exit port of the camera.
Upon cranking in the source, the radiographer had observed the "plunger" drop into position indicating the source had been fully retracted and the auto-locking mechanism engaged. Upon reaching the camera the radiographer key-locked the camera while initiating the required circumference survey. Once locked, the key could not be moved to unlock the camera. The radiographer discovered that the source was not fully shielded and was not locked in place. The camera could not be unlocked to crank the source the extra one eighth turn needed to fully shield the source although it could be cranked out. The manufacturer was contacted and a procedure obtained for by-passing the locking mechanism. The licensee was told by the manufacturer that this type of event is 'extremely rare but it does happen'.
Using the procedure supplied by the manufacturer, the licensee was able to remove the locking assembly, free the key lock, re-set the auto-lock, re-assemble the mechanism and retract the source into its fully shielded
position. No unusual exposures were received by any personnel involved during this event or the successful completion of this operation.
What is the notification or reporting criteria involved? Equipment malfunction: inability to retract source to fully shielded position and secure it in this position.
Activity and isotope(s) involved: 25 curies of Ir-192
Overexposures? NONE
Device (HDR, etc.) Mfg., Model; computer code: I.N.C. model IR 100, serial number 4495"