Event Notification Report for December 08, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
12/07/1999 - 12/08/1999
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36495
Facility: WASHINGTON NUCLEAR (WNP-2)
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: BRIAN ADAMI
HQ OPS Officer: LEIGH TROCINE
Region: 4 State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: BRIAN ADAMI
HQ OPS Officer: LEIGH TROCINE
Notification Date: 12/08/1999
Notification Time: 20:01 [ET]
Event Date: 12/08/1999
Event Time: 13:30 [PST]
Last Update Date: 12/13/1999
Notification Time: 20:01 [ET]
Event Date: 12/08/1999
Event Time: 13:30 [PST]
Last Update Date: 12/13/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(A) - POT UNABLE TO SAFE SD
10 CFR Section:
50.72(b)(2)(iii)(A) - POT UNABLE TO SAFE SD
Person (Organization):
JOSEPH TAPIA (R4)
JOSEPH TAPIA (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
INOPERABILITY OF HIGH PRESSURE CORE SPRAY DUE TO A POTENTIALLY NON-CONSERVATIVE CALCULATED DUTY LOAD CYCLE LOAD PROFILE FOR THE BATTERY
The following text is a portion of a facsimile received from the licensee:
"This is a 4-hour Non-Emergency report in accordance with 10 CFR 50.72 (b)(2)(iii)(A) due to the High Pressure Core Spray (HPCS) system being declared inoperable at 1330 hours PST on December 8, 1999. The plant remains in Mode 1 as allowed by plant technical specifications with the Reactor Core Isolation Cooling (RCIC) system operable."
"HPCS was declared inoperable due to the HPCS battery being declared technically inoperable. The battery was conservatively declared inoperable because the calculated duty cycle load profile that is used for the acceptance criteria in the surveillance for SR 3.8.4.7 appeared to be non-conservative. It is likely that a lower than actual breaker spring charging motor inrush current was used in the calculation. Charging motor current is being confirmed by the vendor[, General Electric]."
The licensee stated that the unit is in a 14-day limiting condition for operation as a result of this issue.
The licensee notified the NRC resident inspector.
* * * RETRACTED AT 1709 EST ON 12/13/99 BY J. W. GASTON TO FANGIE JONES * * *
"This notification is made to retract event report # 36495 made on 12/8/99
"HPCS had been declared inoperable due to the HPCS battery being declared inoperable. The battery was declared inoperable because the calculated load profile was found to be non-conservative. This invalidated the last battery surveillance service test performed for the 24 month Surveillance Requirement 3.8.4.7 because the service test discharge profile was taken from the errant calculation. Upon recalculating the duty cycle profile and reviewing other previously performed service test results it has been determined that a discharge profile used for a service test that was performed on 8/16/98 bounds the recalculated duty cycle for the HPCS battery. Therefore, the Surveillance Requirement 3.8.4.7 is met and no reportable condition exists."
The licensee notified the NRC Resident Inspector. The R4DO (Phil Harrell) was notified.
The following text is a portion of a facsimile received from the licensee:
"This is a 4-hour Non-Emergency report in accordance with 10 CFR 50.72 (b)(2)(iii)(A) due to the High Pressure Core Spray (HPCS) system being declared inoperable at 1330 hours PST on December 8, 1999. The plant remains in Mode 1 as allowed by plant technical specifications with the Reactor Core Isolation Cooling (RCIC) system operable."
"HPCS was declared inoperable due to the HPCS battery being declared technically inoperable. The battery was conservatively declared inoperable because the calculated duty cycle load profile that is used for the acceptance criteria in the surveillance for SR 3.8.4.7 appeared to be non-conservative. It is likely that a lower than actual breaker spring charging motor inrush current was used in the calculation. Charging motor current is being confirmed by the vendor[, General Electric]."
The licensee stated that the unit is in a 14-day limiting condition for operation as a result of this issue.
The licensee notified the NRC resident inspector.
* * * RETRACTED AT 1709 EST ON 12/13/99 BY J. W. GASTON TO FANGIE JONES * * *
"This notification is made to retract event report # 36495 made on 12/8/99
"HPCS had been declared inoperable due to the HPCS battery being declared inoperable. The battery was declared inoperable because the calculated load profile was found to be non-conservative. This invalidated the last battery surveillance service test performed for the 24 month Surveillance Requirement 3.8.4.7 because the service test discharge profile was taken from the errant calculation. Upon recalculating the duty cycle profile and reviewing other previously performed service test results it has been determined that a discharge profile used for a service test that was performed on 8/16/98 bounds the recalculated duty cycle for the HPCS battery. Therefore, the Surveillance Requirement 3.8.4.7 is met and no reportable condition exists."
The licensee notified the NRC Resident Inspector. The R4DO (Phil Harrell) was notified.
Other Nuclear Material
Event Number: 36597
Rep Org: EXXON BIOMEDICAL SCIENCES, INC.
Licensee: EXXON BIOMEDICAL SCIENCES, INC.
Region: 1
City: EAST MILLSTONE State: NJ
County:
License #: 29-19396-01
Agreement: N
Docket:
NRC Notified By: W. JAMES BOVER
HQ OPS Officer: BOB STRANSKY
Licensee: EXXON BIOMEDICAL SCIENCES, INC.
Region: 1
City: EAST MILLSTONE State: NJ
County:
License #: 29-19396-01
Agreement: N
Docket:
NRC Notified By: W. JAMES BOVER
HQ OPS Officer: BOB STRANSKY
Notification Date: 01/17/2000
Notification Time: 11:27 [ET]
Event Date: 12/08/1999
Event Time: 00:00 [EST]
Last Update Date: 01/17/2000
Notification Time: 11:27 [ET]
Event Date: 12/08/1999
Event Time: 00:00 [EST]
Last Update Date: 01/17/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
GLENN MEYER (R1)
CHARLEY HAUGHNEY (NMSS)
GLENN MEYER (R1)
CHARLEY HAUGHNEY (NMSS)
MISSING Ni-63 SEALED SOURCES
The licensee reported that two gas chromatography detectors, each containing 15 mCi of Ni-63 foil, were discovered to be missing during a recent inventory. The detectors were last seen on 12/8/1999. The licensee is currently in the process of moving to a new facility but was unable to find the detectors after searching both facilities. The licensee will continue to search for the sources.
(Call the NRC operations officer for a licensee contact telephone number.)
The licensee reported that two gas chromatography detectors, each containing 15 mCi of Ni-63 foil, were discovered to be missing during a recent inventory. The detectors were last seen on 12/8/1999. The licensee is currently in the process of moving to a new facility but was unable to find the detectors after searching both facilities. The licensee will continue to search for the sources.
(Call the NRC operations officer for a licensee contact telephone number.)