Event Notification Report for November 25, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
11/24/1999 - 11/25/1999

EVENT NUMBERS
3646836463

Hospital
Event Number: 36468
Rep Org: FAIRVIEW SOUTHDALE HOSPITAL
Licensee: FAIRVIEW SOUTHDALE HOSPITAL
Region: 3
City: EDINA   State: MN
County:
License #: 22-00015-02
Agreement: N
Docket:
NRC Notified By: DR. L. LEWANOWSKI
HQ OPS Officer: STEVE SANDIN
Notification Date: 11/26/1999
Notification Time: 23:46 [ET]
Event Date: 11/25/1999
Event Time: 07:05 [CST]
Last Update Date: 11/26/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
35.33 - MED MISADMINISTRATION
Person (Organization):
RONALD GARDNER (R3)
JOE HOLONICH (NMSS)
Event Text
FEMALE PATIENT RECEIVED LESS THAN THE PRESCRIBED DOSE DUE TO TECHNICIAN ERROR

A FEMALE PATIENT UNDERGOING TREATMENT FOR ENDOMETRIAL CANCER RECEIVED 5072 RATHER THAN THE 6500 CENTIGRAY PRESCRIBED DUE TO TECHNICIAN ERROR IN LOADING TWO (2) OLD CESIUM-137 SOURCES INTO THE APPLICATOR. THE NEWER SOURCES (25 MILLIGRAMS RADIUM EQUIVALENT EACH) WERE CLEARLY LABELED AND INDICATED ON THE HOSPITAL FORMS. THE PRESCRIBING PHYSICIAN WAS INFORMED AND REQUESTED THAT THE PATIENT NOT BE NOTIFIED PENDING AN EVALUATION OF WHETHER ADDITIONAL TREATMENT IS REQUIRED. THE LICENSEE WILL SUBMIT A WRITTEN REPORT WITHIN FIFTEEN DAYS.

CALLTHE HEADQUARTERS OPERATIONS OFFICER FOR CONTACT INFORMATION.


Power Reactor
Event Number: 36463
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: ART BREADY
HQ OPS Officer: LEIGH TROCINE
Notification Date: 11/25/1999
Notification Time: 08:36 [ET]
Event Date: 11/25/1999
Event Time: 07:10 [EST]
Last Update Date: 11/25/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
Person (Organization):
CURTIS COWGILL (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF 27 OF 31 OFFSITE EMERGENCY SIRENS

At 0414 on 11/25/99, the Salem County Emergency Call Board notified licensee maintenance personnel that two offsite sirens were inoperable. At 0710, licensee maintenance personnel received a second call from the Salem County Emergency Call Board stating that 27 of 31 offsite sirens were inoperable due to an unplanned power outage. It is uncertain as to when the additional sirens became inoperable after the initial call was received at 0414. Power was restored to the offsite sirens at 0720, and all sirens are currently operable.

A 1-hour report is required to be made to the NRC if greater than 17 offsite sirens are inoperable for more than 1 hour. All safety systems are available and operable with the exception of the 'C' station service water pump which is cleared and tagged for a system outage.

The licensee plans to notify the NRC resident inspector as well as the Lower Alloways Creek Township.