Event Notification Report for November 02, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
11/01/1999 - 11/02/1999
EVENT NUMBERS
3638536386363873638836389
Power Reactor
Event Number: 36385
Facility: PALISADES
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: BOB VINCENT
HQ OPS Officer: DICK JOLLIFFE
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: BOB VINCENT
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/02/1999
Notification Time: 11:45 [ET]
Event Date: 11/02/1999
Event Time: 09:00 [EST]
Last Update Date: 11/03/1999
Notification Time: 11:45 [ET]
Event Date: 11/02/1999
Event Time: 09:00 [EST]
Last Update Date: 11/03/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
JAMES CREED (R3)
JAMES CREED (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
- INDICATIONS DISCOVERED ON CONTROL ROD DRIVE SEAL HOUSINGS -
At 0900 on 11/02/99, a dye penetrant (PT) examination of the control rod drive seal housing for control rod #44 revealed a potential crack-like indication in the Reactor Coolant System pressure boundary. The PT examination was performed to investigate a boric acid deposit on the exterior surface of the housing which was discovered during a previous visual inspection. A small indication was also found on the seal housing for control rod #30. The plant is in a refueling outage. An investigation to characterize the indications and determine their cause and extent is in progress. This situation will be resolved prior to plant restart.
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1432 ON 11/03/99 BY HUGH NIXON TO JOLLIFFE * * *
At 1215 on 11/03/99, a PT examination revealed a circumferential indication on the seal housing for control rod #26.
The licensee notified the NRC Resident Inspector.
The NRC Operations Officer notified the R3DO Jim Creed.
At 0900 on 11/02/99, a dye penetrant (PT) examination of the control rod drive seal housing for control rod #44 revealed a potential crack-like indication in the Reactor Coolant System pressure boundary. The PT examination was performed to investigate a boric acid deposit on the exterior surface of the housing which was discovered during a previous visual inspection. A small indication was also found on the seal housing for control rod #30. The plant is in a refueling outage. An investigation to characterize the indications and determine their cause and extent is in progress. This situation will be resolved prior to plant restart.
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1432 ON 11/03/99 BY HUGH NIXON TO JOLLIFFE * * *
At 1215 on 11/03/99, a PT examination revealed a circumferential indication on the seal housing for control rod #26.
The licensee notified the NRC Resident Inspector.
The NRC Operations Officer notified the R3DO Jim Creed.
Power Reactor
Event Number: 36386
Facility: FT CALHOUN
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ERICK MATZKE
HQ OPS Officer: DICK JOLLIFFE
Region: 4 State: NE
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: ERICK MATZKE
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/02/1999
Notification Time: 17:45 [ET]
Event Date: 11/02/1999
Event Time: 16:00 [CST]
Last Update Date: 11/02/1999
Notification Time: 17:45 [ET]
Event Date: 11/02/1999
Event Time: 16:00 [CST]
Last Update Date: 11/02/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
CLAUDE JOHNSON (R4)
CLAUDE JOHNSON (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Cold Shutdown | 0 | Cold Shutdown |
- STATE NOTIFIED OF AN OIL/GREASE RELEASE IN EXCESS OF THEIR NPDES RELEASE PERMIT LIMIT -
On 10/04/99, a mixture of oil and grease was released from the plant. The licensee sent a composite sample of the mixture to an offsite facility for analysis. At 1600 CST on 11/02/99, the licensee received the results of the analysis and notified the State of Nebraska that the release (13 mg/l) was in excess of the station's NPDES release permit limit (10 mg/l).
The licensee notified the NRC Resident Inspector.
On 10/04/99, a mixture of oil and grease was released from the plant. The licensee sent a composite sample of the mixture to an offsite facility for analysis. At 1600 CST on 11/02/99, the licensee received the results of the analysis and notified the State of Nebraska that the release (13 mg/l) was in excess of the station's NPDES release permit limit (10 mg/l).
The licensee notified the NRC Resident Inspector.
Power Reactor
Event Number: 36387
Facility: GRAND GULF
Region: 4 State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ERNEST MATHES
HQ OPS Officer: DICK JOLLIFFE
Region: 4 State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ERNEST MATHES
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/02/1999
Notification Time: 19:06 [ET]
Event Date: 11/02/1999
Event Time: 16:56 [CST]
Last Update Date: 11/13/1999
Notification Time: 19:06 [ET]
Event Date: 11/02/1999
Event Time: 16:56 [CST]
Last Update Date: 11/13/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
CLAUDE JOHNSON (R4)
CLAUDE JOHNSON (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
- MSIVs LEAKING ABOVE ACCEPTABLE LEAK RATE DURING AN LLRT -
During local leak rate testing with the plant in a refueling outage, the licensee discovered excess leakage past the 'A' main steam line inboard and outboard main steam isolation valves (#B21-F022A and #B21-F028A). This condition exceeded the acceptable leak rate. The licensee is determining corrective action.
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 0331 ON 11/13/99 BY ERNEST MATHES TO JOLLIFFE * * *
During additional local leak rate testing, the licensee discovered gross leakage past the 'C' main steam line inboard and outboard main steam isolation valves (#B21-F022C and #B21-F028C). This condition exceeded the acceptable leak rate. The licensee plans to test the remaining MSIVs and rebuild the leaking valves prior to plant restart.
The licensee notified the NRC Resident Inspector. The NRC Operations Officer notified the R4DO Linda Smith.
During local leak rate testing with the plant in a refueling outage, the licensee discovered excess leakage past the 'A' main steam line inboard and outboard main steam isolation valves (#B21-F022A and #B21-F028A). This condition exceeded the acceptable leak rate. The licensee is determining corrective action.
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 0331 ON 11/13/99 BY ERNEST MATHES TO JOLLIFFE * * *
During additional local leak rate testing, the licensee discovered gross leakage past the 'C' main steam line inboard and outboard main steam isolation valves (#B21-F022C and #B21-F028C). This condition exceeded the acceptable leak rate. The licensee plans to test the remaining MSIVs and rebuild the leaking valves prior to plant restart.
The licensee notified the NRC Resident Inspector. The NRC Operations Officer notified the R4DO Linda Smith.
Power Reactor
Event Number: 36388
Facility: QUAD CITIES
Region: 3 State: IL
Unit: [] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: TOM OSELAND
HQ OPS Officer: DICK JOLLIFFE
Region: 3 State: IL
Unit: [] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: TOM OSELAND
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/02/1999
Notification Time: 20:57 [ET]
Event Date: 11/02/1999
Event Time: 19:01 [CST]
Last Update Date: 11/02/1999
Notification Time: 20:57 [ET]
Event Date: 11/02/1999
Event Time: 19:01 [CST]
Last Update Date: 11/02/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS 50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS 50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
JAMES CREED (R3)
JAMES CREED (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
- HIGH PRESSURE COOLANT INJECTION (HPCI) SYSTEM INOPERABLE -
During performance of the HPCI Steam Exhaust Vacuum Breaker Line Check Valves IST Functional Test, one of four check valves failed to meet its acceptance criteria. The licensee isolated the check valve, declared the HPCI System inoperable, and entered a 14 day LCO. All other Emergency Core Cooling Systems are operable.
The licensee plans to notify the NRC Resident Inspector.
During performance of the HPCI Steam Exhaust Vacuum Breaker Line Check Valves IST Functional Test, one of four check valves failed to meet its acceptance criteria. The licensee isolated the check valve, declared the HPCI System inoperable, and entered a 14 day LCO. All other Emergency Core Cooling Systems are operable.
The licensee plans to notify the NRC Resident Inspector.
Power Reactor
Event Number: 36389
Facility: LASALLE
Region: 3 State: IL
Unit: [] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: LARRY BLUNK
HQ OPS Officer: DICK JOLLIFFE
Region: 3 State: IL
Unit: [] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: LARRY BLUNK
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 11/02/1999
Notification Time: 21:16 [ET]
Event Date: 11/02/1999
Event Time: 19:47 [CST]
Last Update Date: 11/02/1999
Notification Time: 21:16 [ET]
Event Date: 11/02/1999
Event Time: 19:47 [CST]
Last Update Date: 11/02/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
JAMES CREED (R3)
JAMES CREED (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
- OFFSITE AGENCIES NOTIFIED OF THE PRESENCE OF OIL LADEN GRAVEL ONSITE -
The licensee notified the Illinois Emergency Management Agency and the National Response Center of the presence of oil in the pea gravel around the oil filling station underground storage tanks. The oil was present in a two inch layer of gravel at the top of the water table approximately five feet below ground level. The filling station consists of a 10,000 gallon diesel fuel tank, a 10,000 gallon gasoline tank, and a 1,000 gallon waste oil tank. No fire, explosion, or vapor hazards have been identified. The tanks will continue to be excavated for State Fire Marshall inspection on 11/04/99. The oil laden pea gravel will be removed and disposed of properly.
The licensee notified the NRC Resident Inspector.
The licensee notified the Illinois Emergency Management Agency and the National Response Center of the presence of oil in the pea gravel around the oil filling station underground storage tanks. The oil was present in a two inch layer of gravel at the top of the water table approximately five feet below ground level. The filling station consists of a 10,000 gallon diesel fuel tank, a 10,000 gallon gasoline tank, and a 1,000 gallon waste oil tank. No fire, explosion, or vapor hazards have been identified. The tanks will continue to be excavated for State Fire Marshall inspection on 11/04/99. The oil laden pea gravel will be removed and disposed of properly.
The licensee notified the NRC Resident Inspector.