Event Notification Report for October 17, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
10/16/1999 - 10/17/1999
Power Reactor
Event Number: 36302
Facility: BRUNSWICK
Region: 2 State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAVID JENKINS
HQ OPS Officer: LEIGH TROCINE
Region: 2 State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAVID JENKINS
HQ OPS Officer: LEIGH TROCINE
Notification Date: 10/17/1999
Notification Time: 09:37 [ET]
Event Date: 10/17/1999
Event Time: 08:38 [EDT]
Last Update Date: 10/17/1999
Notification Time: 09:37 [ET]
Event Date: 10/17/1999
Event Time: 08:38 [EDT]
Last Update Date: 10/17/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
CAUDLE JULIAN (R2)
JAMES HUFHAM, REG 2 (IRC)
CAUDLE JULIAN (R2)
JAMES HUFHAM, REG 2 (IRC)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
OFFSITE NOTIFICATION REGARDING THE OPENING OF STORM DRAIN BASIN BYPASS VALVES IN PREPARATION FOR THE POTENTIAL ONSET OF HURRICANE IRENE (Refer to event #36300 for additional information.)
The following text is a portion of a facsimile received from the licensee:
"EVENT: On October 17, 1999, at 0838, the bypass valves from the site's storm drain basin directly to the circulating water discharge canal were opened to prevent site flooding (which could cause significant damage to plant equipment and/or possibly endanger personnel safety) due to the potential arrival of Hurricane Irene. Past experience has shown that the installed pump capacity will not keep up with the rain expected during a hurricane. The valves were opened prior to hurricane force winds reaching the site to avoid exposing personnel to the hurricane. Opening these valves is reportable to he state of North Carolina in accordance with the site National Pollutant Discharge Elimination System permit (Permit No. NC0007064)."
"INITIAL SAFETY SIGNIFICANCE EVALUATION: None - Opening these bypass valves will allow storm water from the hurricane to flow directly from the storm drain collection basin to the discharge canal without radiological/chemical monitoring at the stabilization pond. The contents of the basin were sampled prior to opening the bypass valves."
"CORRECTIVE ACTION(S): These bypass valves will be closed as soon as installed systems can cope with the rainfall on site and winds have decreased to a safe level to send personnel out to close them."
The licensee notified the NRC resident inspector.
The following text is a portion of a facsimile received from the licensee:
"EVENT: On October 17, 1999, at 0838, the bypass valves from the site's storm drain basin directly to the circulating water discharge canal were opened to prevent site flooding (which could cause significant damage to plant equipment and/or possibly endanger personnel safety) due to the potential arrival of Hurricane Irene. Past experience has shown that the installed pump capacity will not keep up with the rain expected during a hurricane. The valves were opened prior to hurricane force winds reaching the site to avoid exposing personnel to the hurricane. Opening these valves is reportable to he state of North Carolina in accordance with the site National Pollutant Discharge Elimination System permit (Permit No. NC0007064)."
"INITIAL SAFETY SIGNIFICANCE EVALUATION: None - Opening these bypass valves will allow storm water from the hurricane to flow directly from the storm drain collection basin to the discharge canal without radiological/chemical monitoring at the stabilization pond. The contents of the basin were sampled prior to opening the bypass valves."
"CORRECTIVE ACTION(S): These bypass valves will be closed as soon as installed systems can cope with the rainfall on site and winds have decreased to a safe level to send personnel out to close them."
The licensee notified the NRC resident inspector.
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36303
Facility: FITZPATRICK
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: ED HYNE
HQ OPS Officer: FANGIE JONES
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: ED HYNE
HQ OPS Officer: FANGIE JONES
Notification Date: 10/17/1999
Notification Time: 14:24 [ET]
Event Date: 10/17/1999
Event Time: 13:32 [EDT]
Last Update Date: 11/03/1999
Notification Time: 14:24 [ET]
Event Date: 10/17/1999
Event Time: 13:32 [EDT]
Last Update Date: 11/03/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
JAMES NOGGLE (R1)
JAMES NOGGLE (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
INTEGRATED LEAK TEST FAILURE IN THE REACTOR BUILDING CLOSED COOLING WATER SYSTEM
"Failure of IST [Integrated System Test] testing for RBCLC [reactor building closed loop cooling] containment isolation AOVs resulted in performance of 'as-found' Type-C LLRT. Results of local leak test was 'gross' failure. The failure was determined from inability to obtain test pressure and quantify leakage. Based on these results, it is assumed Tech Spec allowable containment leakage has been exceeded."
The plant will remain shutdown until repairs are made.
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1422 ON 11/03/99 BY MARK ABRANSKI TO JOLLIFFE * * *
The licensee desires to retract this event for the following rational:
The RBCLC piping forms a closed loop inside containment which serves as a redundant containment isolation barrier in the event an RBCLC containment isolation valve fails. Therefore, it need not be assumed that Tech Spec allowable leakage had been exceeded as reported above.
The licensee notified the NRC Resident Inspector.
The NRC Operations Officer notified the R1DO Mohamed Shanbaky.
"Failure of IST [Integrated System Test] testing for RBCLC [reactor building closed loop cooling] containment isolation AOVs resulted in performance of 'as-found' Type-C LLRT. Results of local leak test was 'gross' failure. The failure was determined from inability to obtain test pressure and quantify leakage. Based on these results, it is assumed Tech Spec allowable containment leakage has been exceeded."
The plant will remain shutdown until repairs are made.
The licensee notified the NRC Resident Inspector.
* * * UPDATE AT 1422 ON 11/03/99 BY MARK ABRANSKI TO JOLLIFFE * * *
The licensee desires to retract this event for the following rational:
The RBCLC piping forms a closed loop inside containment which serves as a redundant containment isolation barrier in the event an RBCLC containment isolation valve fails. Therefore, it need not be assumed that Tech Spec allowable leakage had been exceeded as reported above.
The licensee notified the NRC Resident Inspector.
The NRC Operations Officer notified the R1DO Mohamed Shanbaky.
Power Reactor
Event Number: 36304
Facility: INDIAN POINT
Region: 1 State: NY
Unit: [] [3] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: BRIAN HAY
HQ OPS Officer: FANGIE JONES
Region: 1 State: NY
Unit: [] [3] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: BRIAN HAY
HQ OPS Officer: FANGIE JONES
Notification Date: 10/17/1999
Notification Time: 20:13 [ET]
Event Date: 10/17/1999
Event Time: 19:22 [EDT]
Last Update Date: 10/17/1999
Notification Time: 20:13 [ET]
Event Date: 10/17/1999
Event Time: 19:22 [EDT]
Last Update Date: 10/17/1999
Emergency Class: UNUSUAL EVENT
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED
Person (Organization):
JAMES NOGGLE (R1)
WILLIAM BATEMAN (NRR)
FRANK CONGEL (IRO)
GARY BELCHER (FEMA)
JAMES NOGGLE (R1)
WILLIAM BATEMAN (NRR)
FRANK CONGEL (IRO)
GARY BELCHER (FEMA)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | N | 0 | Hot Shutdown | 0 | Hot Shutdown |
UNUSUAL EVENT BASED ON UNIDENTIFIED RCS LEAK GREATER THAN 10 GPM INSIDE CONTAINMENT
An Unusual Event was declared at 1954 EDT due to unidentified or pressure boundary leakage from the reactor coolant system (RCS) greater than 10 gpm, estimated at about 16 gpm, in the containment. At the time, there were personnel in the containment that heard the leak occur and saw steam issuing from a transmitter room. All personnel were evacuated from the containment. There was only a slight increase in radiation indications on containment monitors with no alarms. The leak appears to be from a loop-3 flow transmitter from indications on the control boards.
There was no release of radioactive material to the environment.
The licensee notified the NRC Resident Inspector and state/local authorities.
* * * UPDATE AT 2100 EDT ON 10/17/99 FROM BRIAN HAY TO FANGIE JONES * * *
The Unusual Event was terminated at 2050 EDT. The leak was isolated, it was on an RCS loop-3 flow transmitter.
The licensee notified the NRC Resident Inspector and state/local authorities. The NRC operations center notified the R1DO (James Noggle), NRR EO (William Bateman), IRO (Frank Congel), and FEMA (Bagwell).
An Unusual Event was declared at 1954 EDT due to unidentified or pressure boundary leakage from the reactor coolant system (RCS) greater than 10 gpm, estimated at about 16 gpm, in the containment. At the time, there were personnel in the containment that heard the leak occur and saw steam issuing from a transmitter room. All personnel were evacuated from the containment. There was only a slight increase in radiation indications on containment monitors with no alarms. The leak appears to be from a loop-3 flow transmitter from indications on the control boards.
There was no release of radioactive material to the environment.
The licensee notified the NRC Resident Inspector and state/local authorities.
* * * UPDATE AT 2100 EDT ON 10/17/99 FROM BRIAN HAY TO FANGIE JONES * * *
The Unusual Event was terminated at 2050 EDT. The leak was isolated, it was on an RCS loop-3 flow transmitter.
The licensee notified the NRC Resident Inspector and state/local authorities. The NRC operations center notified the R1DO (James Noggle), NRR EO (William Bateman), IRO (Frank Congel), and FEMA (Bagwell).