Event Notification Report for October 11, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/10/1999 - 10/11/1999

EVENT NUMBERS
362793628036281

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36279
Facility: FERMI
Region: 3     State: MI
Unit: [2] [] []
RX Type: [2] GE-4
NRC Notified By: COSEO
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 10/11/1999
Notification Time: 13:07 [ET]
Event Date: 10/11/1999
Event Time: 09:59 [EDT]
Last Update Date: 11/08/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
JOHN JACOBSON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 97 Power Operation 97 Power Operation
Event Text
VARIOUS SAFETY RELATED EQUIPMENT DECLARED INOPERABLE DUE TO LOSS OF COOLING TO THE BATTERY CHARGER ROOM .

Following startup of the Division 2 Residual Heat Removal Service Water (RHRSW) pumps, it was observed that the Division 2 Emergency Equipment Service Water (EESW) pump was rotating backwards. Division 2 RHRSW flow was normal at greater than 9000 gpm. The Division 2 Ultimate Heat Sink (UHS) service water systems discharge into a common header that can be routed to the Division 2 UHS cooling tower fans or directly to the reservoir. This indicates that the Division 2 EESW pump discharge check valve is not fully closed. The Division 2 EESW pump control was placed in OFF/RESET (normally in AUTO) at 0959 hrs on 10/11/99. The pump discharge valve was closed to isolate the flow path and Division 2 EESW has been declared inoperable. This results in Division 2 Emergency Equipment Cooling Water (EECW) being inoperable. Division 2 EECW provides cooling to the High Pressure Coolant Injection (HPCI) pump area cooler during accident conditions. Therefore, the HPCI system was declared inoperable(14 day LCO) at 0959 on 10/11/99. HPCI remains in standby lineup ready for automatic initiation. The Div 2 EECW also provides cooling to the battery charger room. With the batteries inoperable they are in an 18 hr LCO.

The check valve internals have been inspected and preliminary findings indicate that all parts are intact. The failure of the valve appears to be caused by a worn disc pin in the valve. Necessary repairs are in progress.

The Resident Inspector was notified.

* * * UPDATE AT 1725 ON 11/8/99, BY PHILIPPON TAKEN BY WEAVER * * *

The as found condition and repair of the Emergency Equipment Service Water (EESW) pump discharge check valve, and its effect on the High Pressure Coolant Injection (HPCI) room cooler were evaluated.

The EESW system was operable in the as found condition, until it was removed from service for repair. Based on engineering evaluation of the plant conditions that existed when EESW was removed from service, the HPCI room cooler would not have been required to support HPCI operability. The evaluation showed that HPCI would be able to operate long enough to complete its intended safety function (mitigate an accident) as defined in the Updated Final Safety Analysis Report. Peak room temperature would not have exceeded Environmental Qualification limits or the HPCI equipment room high temperature isolation setpoint. With the room cooler out of service for the EESW check valve repair HPCI remained capable of automatic initiation and operation for the duration necessary to mitigate accidents and transients. Additionally, plant procedures provide directions for bypassing the HPCI equipment room high temperature trip. Consequently, there was no loss of HPCI safety function. Declaring HPCI inoperable was conservative and based on initial considerations. Therefore, event notification 36279 is retracted.

The licensee notified the NRC resident inspector. Notified R3DO (Parker).


Power Reactor
Event Number: 36280
Facility: POINT BEACH
Region: 3     State: WI
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: HASTINGS
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 10/11/1999
Notification Time: 16:56 [ET]
Event Date: 10/11/1999
Event Time: 15:14 [CDT]
Last Update Date: 10/11/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
JOHN JACOBSON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
FIRE BARRIER WALL NOT MEETING THE LICENSEE'S REQUIRED APPENDIX "R" DESIGN BASIS.

IT WAS DISCOVERED THAT A WALL SEGMENT SEPARATING THE CONTROL ROOM FROM THE CABLE SPREADING ROOM PROVIDES ONLY A 1.5 HOUR FIRE BARRIER INSTEAD OF THE 3 HOUR FIRE BARRIER REQUIRED BY THE LICENSEE'S APPENDIX "R" DESIGN COMMITMENTS. THIS PLACES THE WALL SEGMENT OUTSIDE APPENDIX "R" DESIGN BASIS. HOURLY FIRE WATCHES ON BOTH SIDES OF THIS WALL WERE ALREADY IN PLACE PRIOR TO THIS DISCOVERY AND WILL CONTINUE UNTIL THE PROBLEM IS RESOLVED.

THE RESIDENT INSPECTOR WAS INFORMED.


Power Reactor
Event Number: 36281
Facility: PALO VERDE
Region: 4     State: AZ
Unit: [] [] [3]
RX Type: [1] CE,[2] CE,[3] CE
NRC Notified By: STROUD
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 10/11/1999
Notification Time: 19:10 [ET]
Event Date: 10/11/1999
Event Time: 08:40 [MST]
Last Update Date: 10/11/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
KRISS KENNEDY (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
CONTRABAND MATERIAL REPORTED AS A FITNESS-FOR-DUTY ISSUE

CONTRABAND MATERIAL FOUND IN THE VITAL AREA. IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY. THE RESIDENT INSPECTOR WAS NOTIFIED.

CONTACT THE HEADQUARTERS OPERATIONS OFFICER FOR ADDITIONAL DETAILS.