Event Notification Report for October 04, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
10/03/1999 - 10/04/1999

EVENT NUMBERS
362633625736258362593626036271

General Information or Other
Event Number: 36263
Rep Org: SWAGELOK COMPANY
Licensee: SWAGELOK COMPANY
Region: 3
City: Solon   State: OH
County:
License #:
Agreement: N
Docket:
NRC Notified By: BRUCE FLUSCHE (Fax)
HQ OPS Officer: LEIGH TROCINE
Notification Date: 10/06/1999
Notification Time: 09:48 [ET]
Event Date: 10/04/1999
Event Time: 00:00 [EDT]
Last Update Date: 06/23/2000
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
JOHN KINNEMAN (R1)
BRIAN BONSER (R2)
JOHN JACOBSON (R3)
KRISS KENNEDY (R4)
VERN HODGE (NRR)
Event Text
POSSIBLE 10-CFR-PART-21 REPORT REGARDING A POSSIBLE DEFECT IN A SWAGELOK TUBE FITTING

The following text is a portion of a facsimile submitted by Swagelok Company:

"This is a preliminary notification of a possible defect in a Swagelok tube fitting, part number SS-400-3-4TTM, male branch tee. A drawing of the part is included with this notification. We are also notifying each of the involved utilities."

"We became aware of this on October 4, 1999."

"The defect is a crack in the seat of the fitting. We are continuing our analysis of the part and will provide further details in accordance with NRC timetables."

"[The] following are the six utilities to whom we have sold these parts:

Georgia Power [Company], Plant Vogtle, ... , 10 pcs. ... [;]
Duke Power Company, Oconee Nuclear Station, ... ,100 pcs. ... [;]
Arizona Public Service Co., Palo Verde Nuclear Generating Station, ... , 15 pcs. ... [;]
North Atlantic Energy Service Co., ... , Seabrook Station, ... ,10 pcs. ... [;]
Virginia Power, Surry Power Station, ... , 3 pcs. ... [; and]
Omaha Public Power District, Ft. Calhoun Nuclear Station, ... , 10 Pcs. ... ."

(Call the NRC operations officer for Swagelok contact information.)

* * * UPDATE AT 1553 EST ON 11/04/99 FROM BRUCE FLUSCHE TO S. SANDIN * * *

The following information was received via fax:

"We are writing further to our preliminary notification on October 6,1999, about a possible defect in a Swagelok tube fitting, part number SS-400-3-4TTM, male branch tee.

"The utilities to whom we have sold this are repeated in the appendix to this letter.

"As we reported earlier, the defect is a crack in the seat of the fitting. This crank resulted from overheating during the resistive type heated forging process; it was not a defect in the raw material. The estimated per cent of forgings that have this condition is less than 0.03%.

"This forging was processed in December of 1996. Since the middle of 1998 we have required liquid penetrant testing on all resistive type heated forgings.

"If there are any questions, please do not hesitate to contact us."

The NRC operations officer notified the R1DO (Mohamed Shanbaky), R2DO (Pierce Skinner), R3DO (James Creed), and R4DO (Claude Johnson). This report was also faxed to NRR Part 21 (Vern Hodge).

******************** UPDATE AT 0934 ON 12/17/99 FROM BRUCE FLUSCHE TO TROCINE ********************

The following text is a portion of a facsimile submitted by Swagelok Company:

"Further to our notice of November 18,1999, on Swagelok part number SS-400-3-4TTM, we are providing further information. As earlier reported the licensee below was not notified:

Florida Power and Light
P0. #00029212
5 pcs. SS-400-3-4TTM
Product ID. R17KLO5O9B"

"The reason for the lack of notification was that the certification had not been entered into our database. The associate responsible for entering the certifications is no longer with Swagelok, and we have scheduled an audit of our database for the time period from June 1997 through July 1999, as we believe this is the time period that most needs to be scrutinized."

"Whether further review of the database is necessary will be determined on the findings of this audit."

The NRC operations officer notified the R1DO (Ruland), R2DO (Boland), R3DO (Gardner), and R4DO (Harrell). This report was also faxed to NRR Part 21 (Vern Hodge).

* * * UPDATE AT 1100 ON 06/23/00 BY JAMES HANSON TO JOLLIFFE * * *

Swagelok company personnel have determined that five additional certifications have been found where it cannot be verified that the corresponding licensees have been contacted. This includes licensees for the following plants: Susquehanna, North Anna, Duane Arnold, and San Onofre.

The NRC Operations Officer notified the R1DO Bob Summers, R2DO Rudy Bernhard, R3DO Mike Jordan, R4DO Joe Tapia and NRR Vern Hodge (by fax).


Power Reactor
Event Number: 36257
Facility: COMANCHE PEAK
Region: 4     State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: TERRY MARSH
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/04/1999
Notification Time: 09:11 [ET]
Event Date: 10/04/1999
Event Time: 06:30 [CDT]
Last Update Date: 10/04/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
KRISS KENNEDY (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
GREATER THAN 1% OF STEAM GENERATOR #4 (WESTINGHOUSE MODEL "D4") TUBES HAVE BEEN FOUND TO BE POTENTIALLY DEFECTIVE

MORE THAN 1% (46 TUBES OR MORE) OF THE INSPECTED (INSPECTION STILL IN PROGRESS) IN #4 STEAM GENERATOR ARE POTENTIALLY DEFECTIVE. THE DEFECTIVE TUBES ARE BEING EVALUATED TO BE REMOVED OUT OF SERVICE. THIS EVENT MEETS THE CRITERIA OF C-3 AS DEFINED IN COMANCHE PEAK STEAM GENERATION STATION TECHNICAL SPECIFICATION SECTION 5.5.9. ADDITIONAL DATA IS BEING COLLECTED AND WILL BE ANALYZED TO ASSIST IN DETERMINING THE CAUSE OF THIS EVENT. EACH STEAM GENERATOR AT COMANCHE PEAK HAS 4578 TUBES. STEAM GENERATOR #4 SO FAR IN THE INSPECTION PROCESS HAS 49 POTENTIALLY DEFECTIVE TUBES.

THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS EVENT BY THE LICENSEE.


Power Reactor
Event Number: 36258
Facility: QUAD CITIES
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: DARYL NOHR
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 10/04/1999
Notification Time: 11:27 [ET]
Event Date: 10/04/1999
Event Time: 09:20 [CDT]
Last Update Date: 10/04/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
JOHN JACOBSON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
POTENTIAL COMPROMISE OF SAFEGUARDS INFORMATION

Immediate compensatory measures taken upon discovery.

The NRC Resident will be notified.

Refer to HOO log for additional details.


Power Reactor
Event Number: 36259
Facility: POINT BEACH
Region: 3     State: WI
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: MIKE MEYER
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 10/04/1999
Notification Time: 14:49 [ET]
Event Date: 10/04/1999
Event Time: 13:21 [CDT]
Last Update Date: 10/04/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
JOHN JACOBSON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
OUTSIDE DESIGN BASIS DUE TO POTENTIAL FOR A FIRE TO ISOLATE NORMAL AND ALTERNATE SUPPLY SOURCES TO THE CHARGING PUMPS.

During an Appendix R Rebaselining project it was discovered that the potential exists for a fire to isolate the normal and alternate water supply sources to the Unit 1 or 2 charging pumps. Valve CV-112C (Normal Supply) and CV-112B (Alternate RWST) for either unit has virtually the same cable routing. The licensee has initiated fire rounds in all affected fire zones.

The NRC Resident will be notified.


Power Reactor
Event Number: 36260
Facility: QUAD CITIES
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-3,[2] GE-3
NRC Notified By: KEN HILL
HQ OPS Officer: JOHN MacKINNON
Notification Date: 10/05/1999
Notification Time: 03:52 [ET]
Event Date: 10/04/1999
Event Time: 23:55 [CDT]
Last Update Date: 10/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
JOHN JACOBSON (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
HIGH PRESSURE COOLANT INJECTION (HPCI) DECLARED INOPERABLE

HPCI OUTBOARD STEAM SUPPLY ISOLATION VALVE, MO 1-2301-5, WAS UNABLE TO BE CLOSED USING THE CONTROL ROOM CONTROL SWITCH DURING A PLANNED VALVE TIMING SURVEILLANCE PRIOR TO A PLANNED HPCI SYSTEM OUTAGE. PRIOR TO THIS, AT 2348 CDT ON 10/4/99, THE HPCI SYSTEM WAS MADE INOPERABLE WHEN THE INBOARD STEAM SUPPLY ISOLATION VALVE, MO 1-2301-4, WAS CLOSED AS PART OF THE VALVE TIMING SURVEILLANCE TO ALLOW TESTING OF THE OUTBOARD VALVE. SINCE MO 1-2301-5 COULD NOT BE CLOSED, MO 1-2301-4 WAS KEPT CLOSED TO COMPLY WITH TECHNICAL SPECIFICATIONS 3.5.a ACTION STATEMENTS AND STATION PROCEDURES FOR AN INOPERABLE CONTAINMENT ISOLATION VALVE. HPCI COULD NOT BE RETURNED TO SERVICE, AS PLANNED, AND REMAINS INOPERABLE. ALL EMERGENCY CORE COOLING SYSTEMS, EMERGENCY DIESEL GENERATORS, AND REACTOR CORE ISOLATION COOLING SYSTEM ARE FULLY OPERABLE.

THE NCR RESIDENT INSPECTOR WAS NOTIFIED OF THIS EVENT BY THE LICENSEE.


Other Nuclear Material
Event Number: 36271
Rep Org: WEST VIRGINIA UNIVERSITY
Licensee: WEST VIRGINIA UNIVERSITY
Region: 2
City: MORGANTOWN   State: WV
County:
License #: 47-23035-01
Agreement: N
Docket:
NRC Notified By: KEN DOUGLASS
HQ OPS Officer: BOB STRANSKY
Notification Date: 10/07/1999
Notification Time: 14:22 [ET]
Event Date: 10/04/1999
Event Time: 00:00 [EDT]
Last Update Date: 10/07/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
BRIAN BONSER (R2)
DON COOL (NMSS)
JOHN DAVIDSON (IAT)
BARRY MANILLI (IAT)
Event Text
TRITIUM-FILLED EXIT SIGNS STOLEN FROM CREATIVE ARTS CENTER BUILDING

On 10/4/1999, a University administrative assistant noticed that a tritium-filled exit sign had been stolen from a hallway in the creative arts building. Upon further investigation, the licensee determined that up to five other signs were also missing from the building. The campus police were notified, and a public safety report was filed. The licensee believes that the signs were stolen during the weekend of 10/2-3/1999. The licensee is currently researching specific information regarding the signs (model number and activity).

The licensee may make a press release regarding this event.