EVENT NUMBERS
3625236253362543625036322
Power Reactor
Event Number: 36252
Facility: PILGRIM
Region: 1 State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: FRANCIS CLIFFORD
HQ OPS Officer: STEVE SANDIN
Region: 1 State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: FRANCIS CLIFFORD
HQ OPS Officer: STEVE SANDIN
Notification Date: 10/01/1999
Notification Time: 11:52 [ET]
Event Date: 10/01/1999
Event Time: 11:00 [EDT]
Last Update Date: 10/01/1999
Notification Time: 11:52 [ET]
Event Date: 10/01/1999
Event Time: 11:00 [EDT]
Last Update Date: 10/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
70.52(a) - LOSS OF SNM/CRIT
10 CFR Section:
70.52(a) - LOSS OF SNM/CRIT
Person (Organization):
DAVID SILK (R1)
JOSIE PICCONE (NMSS)
JOSEPH GIITTER (IRO)
MICHAEL WEBER (IAT) (NMSS)
DAVID SILK (R1)
JOSIE PICCONE (NMSS)
JOSEPH GIITTER (IRO)
MICHAEL WEBER (IAT) (NMSS)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
HISTORICAL REPORT INVOLVING MISPLACEMENT OF SPECIAL NUCLEAR MATERIAL
"This is a late report of a loss of a very small amount of Special Nuclear Material (SNM) that occurred on July 29, 1998. For a period of no more than 29 days, 4 IRMs were not properly stored in the spent fuel pool, their designated storage area. Because the IRMs were subsequently found within the RCA, this event was not initially reported. On subsequent review associated with closing out corrective action associated with the event,
it has been found that the original determination that the IRMs were not lost was not conservative, and that this event should have been reported in 1998. This report corrects that error. All SNM is currently accounted for at Pilgrim Station."
The licensee informed the NRC Resident Inspector.
"This is a late report of a loss of a very small amount of Special Nuclear Material (SNM) that occurred on July 29, 1998. For a period of no more than 29 days, 4 IRMs were not properly stored in the spent fuel pool, their designated storage area. Because the IRMs were subsequently found within the RCA, this event was not initially reported. On subsequent review associated with closing out corrective action associated with the event,
it has been found that the original determination that the IRMs were not lost was not conservative, and that this event should have been reported in 1998. This report corrects that error. All SNM is currently accounted for at Pilgrim Station."
The licensee informed the NRC Resident Inspector.
Fuel Cycle Facility
Event Number: 36253
Facility: ALLIED-SIGNAL INC.
Region: 3 State: IL
Unit: [] [] []
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
NRC Notified By: HUGH ROBERTS
HQ OPS Officer: STEVE SANDIN
Region: 3 State: IL
Unit: [] [] []
RX Type: URANIUM HEXAFLUORIDE PRODUCTION
NRC Notified By: HUGH ROBERTS
HQ OPS Officer: STEVE SANDIN
Notification Date: 10/01/1999
Notification Time: 14:11 [ET]
Event Date: 10/01/1999
Event Time: 12:45 [CDT]
Last Update Date: 10/01/1999
Notification Time: 14:11 [ET]
Event Date: 10/01/1999
Event Time: 12:45 [CDT]
Last Update Date: 10/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
TONY VEGEL (R3)
JOSIE PICCONE (NMSS)
JOSEPH GIITTER (IRO)
TONY VEGEL (R3)
JOSIE PICCONE (NMSS)
JOSEPH GIITTER (IRO)
BRUSH FIRE ON ALLIED SIGNAL PROPERTY REQUIRING OFFSITE ASSISTANCE
AT APPROXIMATELY 1245CDT, A BRUSH FIRE ERUPTED ON THE NORTHEAST SIDE OF THE ALLIED SIGNAL FACILITY BETWEEN HIGHWAY 45 AND THE RAILROAD TRACKS. THE LOCAL FIRE DEPARTMENT RESPONDED. THE FIRE INVOLVES A SECTION OF THE PROPERTY ABOUT 0.25 MILES IN LENGTH BY 100 YARDS WIDE. THE FIRE DEPARTMENT IS STILL ON THE SCENE AND REPORTS THAT THE FIRE IS UNDER CONTROL. THE LICENSEE WILL INFORM THE NRC REGION III OFFICE AS A COURTESY.
AT APPROXIMATELY 1245CDT, A BRUSH FIRE ERUPTED ON THE NORTHEAST SIDE OF THE ALLIED SIGNAL FACILITY BETWEEN HIGHWAY 45 AND THE RAILROAD TRACKS. THE LOCAL FIRE DEPARTMENT RESPONDED. THE FIRE INVOLVES A SECTION OF THE PROPERTY ABOUT 0.25 MILES IN LENGTH BY 100 YARDS WIDE. THE FIRE DEPARTMENT IS STILL ON THE SCENE AND REPORTS THAT THE FIRE IS UNDER CONTROL. THE LICENSEE WILL INFORM THE NRC REGION III OFFICE AS A COURTESY.
Power Reactor
Event Number: 36254
Facility: INDIAN POINT
Region: 1 State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: VASELY
HQ OPS Officer: CHAUNCEY GOULD
Region: 1 State: NY
Unit: [2] [] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: VASELY
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 10/01/1999
Notification Time: 22:04 [ET]
Event Date: 10/01/1999
Event Time: 18:18 [EDT]
Last Update Date: 10/02/1999
Notification Time: 22:04 [ET]
Event Date: 10/01/1999
Event Time: 18:18 [EDT]
Last Update Date: 10/02/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
DAVID SILK (R1)
DAVID SILK (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | N | 0 | Hot Shutdown | 0 | Hot Shutdown |
POSSIBLE PRESS RELEASE MAY BE MADE.
THE ON DUTY SHIFT SECURITY SUPERVISOR ACCIDENTALLY DISCHARGED HIS WEAPON WHILE IN THE PROCESS OF CLEANING IT. THE DISCHARGED ROUND PENETRATED A STORAGE CABINET AND LODGED IN A TACTICAL VEST. THIS OCCURRED IN THEIR SECONDARY ALARM STATION INSIDE THE PROTECTED AREA. NO ONE WAS INJURED DURING THIS INCIDENT AND THEY ARE THINKING OF MAKING A PRESS RELEASE.
THE RESIDENT INSPECTOR WAS NOTIFIED.
* * * UPDATE ON 10/02/99 AT 0830ET BY D. CORNAX TAKEN BY MACKINNON * * *
AT THE TIME OF THE OCCURRENCE OF THIS EVENT A WACKENHUT SUPERVISOR CONDUCTING A WEAPONS INVENTORY CHECK WAS STANDING NEXT TO THE ON DUTY SECURITY SHIFT SUPERVISOR. THE SPENT SHELL CASING STRUCK THE WACKENHUT SUPERVISOR ABOVE THE LEFT EYE CAUSING A SLIGHT SCRATCH. HE ALSO EXPERIENCED SOME HEARING DISCOMFORT FROM THE NOISE. THE WACKENHUT SUPERVISOR WAS SENT TO THE HUDSON VALLEY HOSPITAL BY THE SECURITY SHIFT SUPERVISOR AND WACKENHUT PROJECT MANAGER FOR PRECAUTIONARY HEARING EXAMINATION. HE RETURNED TO WORK AT 2050 HOURS ON 10/01/99.
R1DO (DAVID SILK), NMSS IAT (JOHN DAVIDSON) AND IRO (JOE GIITTER) NOTIFIED.
THE NRC RESIDENT INSPECTOR WILL BE CONTACTED BY THE LICENSEE.
THE ON DUTY SHIFT SECURITY SUPERVISOR ACCIDENTALLY DISCHARGED HIS WEAPON WHILE IN THE PROCESS OF CLEANING IT. THE DISCHARGED ROUND PENETRATED A STORAGE CABINET AND LODGED IN A TACTICAL VEST. THIS OCCURRED IN THEIR SECONDARY ALARM STATION INSIDE THE PROTECTED AREA. NO ONE WAS INJURED DURING THIS INCIDENT AND THEY ARE THINKING OF MAKING A PRESS RELEASE.
THE RESIDENT INSPECTOR WAS NOTIFIED.
* * * UPDATE ON 10/02/99 AT 0830ET BY D. CORNAX TAKEN BY MACKINNON * * *
AT THE TIME OF THE OCCURRENCE OF THIS EVENT A WACKENHUT SUPERVISOR CONDUCTING A WEAPONS INVENTORY CHECK WAS STANDING NEXT TO THE ON DUTY SECURITY SHIFT SUPERVISOR. THE SPENT SHELL CASING STRUCK THE WACKENHUT SUPERVISOR ABOVE THE LEFT EYE CAUSING A SLIGHT SCRATCH. HE ALSO EXPERIENCED SOME HEARING DISCOMFORT FROM THE NOISE. THE WACKENHUT SUPERVISOR WAS SENT TO THE HUDSON VALLEY HOSPITAL BY THE SECURITY SHIFT SUPERVISOR AND WACKENHUT PROJECT MANAGER FOR PRECAUTIONARY HEARING EXAMINATION. HE RETURNED TO WORK AT 2050 HOURS ON 10/01/99.
R1DO (DAVID SILK), NMSS IAT (JOHN DAVIDSON) AND IRO (JOE GIITTER) NOTIFIED.
THE NRC RESIDENT INSPECTOR WILL BE CONTACTED BY THE LICENSEE.
Power Reactor
Event Number: 36250
Facility: CRYSTAL RIVER
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] B&W-L-LP
NRC Notified By: RICKY RAWLS
HQ OPS Officer: DOUG WEAVER
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] B&W-L-LP
NRC Notified By: RICKY RAWLS
HQ OPS Officer: DOUG WEAVER
Notification Date: 10/01/1999
Notification Time: 03:51 [ET]
Event Date: 10/01/1999
Event Time: 01:14 [EDT]
Last Update Date: 10/01/1999
Notification Time: 03:51 [ET]
Event Date: 10/01/1999
Event Time: 01:14 [EDT]
Last Update Date: 10/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
RUDOLPH BERNHARD (R2)
RUDOLPH BERNHARD (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 4 | Startup | 4 | Startup |
EMERGENCY FEEDWATER START
The unit was in the process of a normal plant shut down for a refueling outage when the running Main Feedwater pump (MFP-2A) tripped. The tripping of the only running feedwater pump caused Emergency Feedwater to actuate (EFP-1 and EFP-2). The plant did not experience any abnormal changes in OTSG level or other systems. The cause of the MFP trip is unknown at this time. The "B" MFP (MFP-2B) was started and emergency feedwater secured and reset.
The licensee informed the NRC resident inspector.
The unit was in the process of a normal plant shut down for a refueling outage when the running Main Feedwater pump (MFP-2A) tripped. The tripping of the only running feedwater pump caused Emergency Feedwater to actuate (EFP-1 and EFP-2). The plant did not experience any abnormal changes in OTSG level or other systems. The cause of the MFP trip is unknown at this time. The "B" MFP (MFP-2B) was started and emergency feedwater secured and reset.
The licensee informed the NRC resident inspector.
Other Nuclear Material
Event Number: 36322
Rep Org: BATTELLE MEMORIAL INSTITUTE
Licensee: BATTELLE MEMORIAL INSTITUTE
Region: 3
City: COLUMBUS State: OH
County:
License #:
Agreement: N
Docket:
NRC Notified By: CRAIG JENSEN
HQ OPS Officer: BOB STRANSKY
Licensee: BATTELLE MEMORIAL INSTITUTE
Region: 3
City: COLUMBUS State: OH
County:
License #:
Agreement: N
Docket:
NRC Notified By: CRAIG JENSEN
HQ OPS Officer: BOB STRANSKY
Notification Date: 10/20/1999
Notification Time: 16:33 [ET]
Event Date: 10/01/1999
Event Time: 00:00 [EDT]
Last Update Date: 10/20/1999
Notification Time: 16:33 [ET]
Event Date: 10/01/1999
Event Time: 00:00 [EDT]
Last Update Date: 10/20/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
BRUCE JORGENSEN (R3)
CHARLEY HAUGHNEY (NMSS)
BRUCE JORGENSEN (R3)
CHARLEY HAUGHNEY (NMSS)
LOST STATIC ELIMINATOR
A static eliminator, attached to a balance scale, cannot be accounted for, and is presumed to have been discarded. The device is an NRD model 2U-500 static eliminator, with a nominal 500 µCi Po-210 source (current source strength <50 µCi). The device was last inventoried in 4/99. The caller stated that the scale to which the device had been attached has been discarded, and that the device could not be located during a 10/1/99 inventory.
A static eliminator, attached to a balance scale, cannot be accounted for, and is presumed to have been discarded. The device is an NRD model 2U-500 static eliminator, with a nominal 500 µCi Po-210 source (current source strength <50 µCi). The device was last inventoried in 4/99. The caller stated that the scale to which the device had been attached has been discarded, and that the device could not be located during a 10/1/99 inventory.