Skip to main content

Event Notification Report for September 26, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/25/1999 - 09/26/1999

EVENT NUMBERS
36232

Power Reactor
Event Number: 36232
Facility: VOGTLE
Region: 2     State: GA
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHARLIE MEYER
HQ OPS Officer: BOB STRANSKY
Notification Date: 09/26/1999
Notification Time: 06:45 [ET]
Event Date: 09/26/1999
Event Time: 03:30 [EDT]
Last Update Date: 09/26/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
THOMAS DECKER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 93 Power Operation 93 Power Operation
Event Text
BOTH TRAINS OF THE SAFETY INJECTION SYSTEM DECLARED INOPERABLE

Both trains of the safety injection (SI) system were declared inoperable due to the discovery of excessive volumes of air from both SI pump casings. The air was discovered during performance of the monthly ECCS flow path verification surveillance procedure. Both pumps were subsequently vented and declared operable at 0610 9/26/1999. The licensee is investigating the cause of the entrapped air.

The NRC resident inspector has been informed of this event by the licensee.