Skip to main content

Event Notification Report for September 25, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
09/24/1999 - 09/25/1999

EVENT NUMBERS
36231

Power Reactor
Event Number: 36231
Facility: SALEM
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: S. SAUER
HQ OPS Officer: BOB STRANSKY
Notification Date: 09/26/1999
Notification Time: 00:52 [ET]
Event Date: 09/25/1999
Event Time: 23:30 [EDT]
Last Update Date: 09/26/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
ROBERT SUMMERS (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
CONTAINMENT VENTILATION ISOLATION

An automatic containment ventilation isolation (CVI) was initiated by the containment air particulate monitor (1R11A). The containment purge system was in service at the time, and the system isolated as designed. The licensee is currently evaluating the cause of this isolation, and is obtaining and analyzing grab samples to determine whether an increase in particulate activity may have occurred.

The NRC resident inspector will be informed of this event by the licensee.