!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36198
Facility: MILLSTONE
Region: 1     State: CT
Unit: [] [2] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: MYERS
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 09/19/1999
Notification Time: 08:15 [ET]
Event Date: 09/19/1999
Event Time: 07:30 [EDT]
Last Update Date: 09/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
Person (Organization):
NIEL DELLA GRECA (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A N 0 Hot Standby 0 Hot Standby
Event Text
THE PLANT HAD AN RPS ACTUATION ON A LOW LEVEL STEAM GENERATOR SIGNAL.

The plant had a reactor protection signal actuation due to an actual low level steam generator trip signal. The reactor was already shut down with all rods fully inserted, so there was no affect on the reactor from this actuation. The steam generator level was restored to above the low level trip setpoint. The cause of the low steam generator level appears to be due to inadequate procedures, but they are still investigating.

The NRC resident inspector along with state and local agencies were notified by the licensee.

****************** UPDATE AT 1314 ON 09/29/99 FROM KEN TRUESDALE TO LEIGH TROCINE *****************

The following text is a portion of a facsimile received from the licensee:

"Background"

"A valid low steam generator lever signal was processed through the Reactor Protection System (RPS) coincident logic. This signal was not expected because steam generator level was being maintained by control room personnel within the band required/allowed by the applicable procedure. At the time of the trip signal, the reactor was in Mode 3 with the Trip Circuit Breakers (TCB) open. At the time the ESF signal was generated, a normal reactor shutdown had been completed (entry into Mode 3), control rods had been inserted, and steam generator level was being maintained within a specified range as required by the applicable procedure."

"Reportability"

"For the steam generator level trip event, an ESF was not needed to mitigate the consequences of an event, and an ESF did not actuate as a result of the trip signal. A normal reactor shutdown had been completed (entry into Mode 3), control rods had previously been inserted, and steam generator level was being maintained within a specified range as required by the applicable procedure. For the MP2 steam generator trip event, the consequences of an event were not mitigated, and an ESF component did not actuate. Therefore, since an ESF signal did not process to an ESF component (TCBs were open), an actuation did not occur, and an event did not exist which required mitigation; this report is being retracted."

The licensee notified the NRC resident inspector. The NRC operations center notified the R1DO (Silk).


Power Reactor
Event Number: 36199
Facility: SAINT LUCIE
Region: 2     State: FL
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: STEVE MERRILL
HQ OPS Officer: LEIGH TROCINE
Notification Date: 09/19/1999
Notification Time: 13:24 [ET]
Event Date: 09/19/1999
Event Time: 11:00 [EDT]
Last Update Date: 09/19/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
CHRIS CHRISTENSEN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
2 N Y 100 Power Operation 100 Power Operation
Event Text
OFFSITE NOTIFICATION DUE TO DISCOVERY OF A DEAD SEA TURTLE IN THE INTAKE CANAL

At 1100 EDT, the licensee discovered a dead green sea turtle in the plant's intake canal. In accordance with the licensee's marine turtle permit (which is part of the licensee's Environmental Protection Plan), the licensee notified the Department of Environmental Protection's Bureau of Protected Species at 1145 EDT.

The licensee plans to notify the NRC resident inspector.


Power Reactor
Event Number: 36200
Facility: HOPE CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: JOHN MILLER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 09/19/1999
Notification Time: 17:13 [ET]
Event Date: 09/19/1999
Event Time: 16:30 [EDT]
Last Update Date: 09/19/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
NIEL DELLA GRECA (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FAILURE OF A SINGLE TRAIN SAFETY SYSTEM (HIGH PRESSURE COOLANT INJECTION)

The following text is a portion of a facsimile received from the licensee:

"At 1630 on 09/19/99 after the I&C Department was unable to successfully complete a scheduled surveillance activity, the high pressure coolant injection system was declared inoperable. Initial troubleshooting indicates that a card failure has resulted in a sealed-in trip signal. Hope Creek is currently at 100% power with no other systems inoperable. Actions to restore the high pressure coolant injection system to an operable status are underway."

The licensee stated that surveillance was being performed on one of the trip signals and that one of the cards that regulates voltage for this trip signal appears to have failed in a semi-energized state. This signal provides just enough of a voltage to keep the trip signal in. As a result, the licensee is in the process of obtaining a replacement card. This event places the unit in a 14-day technical specification limiting condition for operation.

The licensee plans to notify the NRC resident inspector and the Lower Alloways Creek Township.