General Information or Other
Event Number: 36228
Rep Org: WASHINGTON DEPARTMENT OF HEALTH
Licensee: WHEELABRATOR
Region: 4
City: SPOKANE   State: WA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: TERRY FRAZEE
HQ OPS Officer: FANGIE JONES
Notification Date: 09/24/1999
Notification Time: 18:55 [ET]
Event Date: 09/09/1999
Event Time: 00:00 [PDT]
Last Update Date: 09/24/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
LAWRENCE YANDELL (R4)
JOHN SURMEIER (NMSS)
Event Text
WASTE-TO-ENERGY FACILITY HAD RADIATION ALARM ON INCOMING LOAD

Agreement State Event Report #WA-99-025

The following text is a portion of E-mail received from the Washington Department of Health, Division of Radiation Protection:

"A waste-to-energy facility in Spokane reported a radiation alarm on an incoming load of residential waste. The facility separated the load, finding a plastic bag with "kitty litter" reading about 8 mR/hr on contact. They notified DOH and isolated the material in their locked storage area. On September 15, 1999, DOH staff identified the offending radionuclide to be I-131 and confirmed that the contents appeared to be cat litter. There was no accompanying waste that could identify the origin of the waste. It is presumed that a local cat was receiving
treatment for a thyroid condition and had been released to its owner with a small amount of residual radioactivity (only a few microcuries were present in the litter). The material is being held for decay.

"Activity and Isotope(s) involved: An unknown (but small) amount of I-131"


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Fuel Cycle Facility
Event Number: 36143
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: ERIC SPAETH
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 09/10/1999
Notification Time: 11:39 [ET]
Event Date: 09/09/1999
Event Time: 15:00 [EDT]
Last Update Date: 09/18/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2)(ii) - EQUIP DISABLED/FAILS
Person (Organization):
MONTE PHILLIPS (R3)
JOSIE PICCONE (NMSS)
Event Text
CRITICALITY ACCIDENT ALARM SYSTEM HORN INOPERABLE DUE TO IMPROPER CONNECTION

At 1500 hours, on 09/09/99, the Criticality Accident Alarm System (CAAS) slave horn in the X-344B building was discovered to be not connected to the X-344A CAAS evacuation alarm as designed. During troubleshooting activities, maintenance personnel found that the horn was connected to the gas release alarm system instead of the CAAS evacuation horn system.

This condition is reportable to the NRC per 10 CFR 76.120(c), "Safety Equipment Failure/Actuation." The equipment is required by a technical safety requirement (TSR) to be available and operable, and no redundant equipment is available and operable to perform the required safety function.

There was no loss of hazardous material or radioactive/radiological contamination exposure as a result of this event.

The NRC resident inspector has been notified by Portsmouth personnel.

*** UPDATE ON 09/18/99 @ 1007 FROM HALCOMB TO GOULD *** EVENT RETRACTION

THIS EVENT IS BEING RETRACTED AFTER FURTHER INVESTIGATION AND TESTING HAS DETERMINED THAT THE X-344B FACILITY EVACUATION HORN IS NOT NEEDED TO SATISFY TSR AUDIBILITY REQUIREMENTS SINCE THE X-344A EAST CLUSTER HORN PROVIDES THE REQUIRED AUDIBILITY. THEREFORE, REPORTABILITY WAS NOT REQUIRED.

PORTSMOUTH PERSONNEL NOTIFIED THE NRC RESIDENT INSPECTOR AND PLAN TO NOTIFY THE DEPARTMENT OF ENERGY SITE REPRESENTATIVE. THE R3DO (SHEAR) AND NMSS EO (SHERR) WERE NOTIFIED BY THE NRC OPERATIONS OFFICER.


Power Reactor
Event Number: 36140
Facility: GRAND GULF
Region: 4     State: MS
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ERNEST MATHES
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 09/09/1999
Notification Time: 14:45 [ET]
Event Date: 09/09/1999
Event Time: 11:48 [CDT]
Last Update Date: 09/09/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
GARY SANBORN (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
DIVISION III EMERGENCY DIESEL GENERATOR (EDG) FAILURE.

The division III EDG was emergency stopped during a 24 hour surveillance run. Preliminary indications are that the generator bearing failed as indicated by high bearing temperature and sparks from the generator area just prior to emergency stopping the EDG. The diesel was started at 1055 CDT and secured at 1148 CDT. The licensee is investigating the cause of the failure.

The NRC resident inspector has been notified.


Other Nuclear Material
Event Number: 36141
Rep Org: DC FABRICATORS
Licensee: DC FABRICATORS
Region: 1
City: FLORENCE   State: NJ
County:
License #:
Agreement: N
Docket:
NRC Notified By: DONALD BRAMBLE
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 09/09/1999
Notification Time: 15:30 [ET]
Event Date: 09/09/1999
Event Time: 00:00 [EDT]
Last Update Date: 09/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
TOM MOSLAK (R1)
JOHN HICKEY (NMSS)
GARY SANBORN (R4)
Event Text
ALLOY IDENTIFICATION INSTRUMENT LOST DURING SHIPMENT

On March 14, 1999, DC Fabricators shipped a small alloy identification instrument to Texas Nuclear Technology via UPS. In early August, DC Fabricators determined that the instrument had not arrived at Texas Nuclear Technology. The device contains 45 millicuries of Fe-55 and 4 millicuries of Cd-109. UPS is looking for the device but has been unable to locate it to date.

* * * UPDATE 1016 9/27/1999 FROM BRAMBLE TAKEN BY STRANSKY * * *

The package has been located. It was delivered by UPS to the Texas Nuclear facility, but the driver left it at the main entrance, not the receiving department. The receptionist at the main entrance was a new hire and did not know to send the package to the receiving department. The package was subsequently misplaced temporarily. The licensee has contacted the NRC Region I office regarding this update. Notified R1DO (Hinson).