Event Number: 36103
Rep Org: ENGINEERING CONSULTANT SERVICES
Licensee: ENGINEERING CONSULTANT SERVICES
Region: 2
City: FREDRICKSBURG   State: VA
County: SPOTSYLVANIA
License #: 45-24974-01
Agreement: N
Docket:
NRC Notified By: JEFFREY STICKOVITCH
HQ OPS Officer: STEVE SANDIN
Notification Date: 08/31/1999
Notification Time: 15:38 [ET]
Event Date: 08/30/1999
Event Time: 15:30 [EDT]
Last Update Date: 08/31/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
KERRY LANDIS (R2)
JOSEPHINE PICCONE (NMSS)
Event Text
TROXLER GAUGE DAMAGED DURING CONSTRUCTION

DURING CONSTRUCTION ACTIVITIES AT STAFFORD LAKES, VA, A TROXLER MODEL CPN GAUGE CONTAINING 10mCi CESIUM-137 AND 50 mCi AMERICIUM-241/BERYLLIUM WAS INADVERTENTLY RUN OVER BY A PAN LOADER, CRUSHING THE CASE. THE AREA WAS ROPED OFF AND SURVEYED. THERE WAS NO INDICATION THAT THE SEALED SOURCE WAS DAMAGED. PER PROCEDURE THE LICENSEE IS SENDING THE DAMAGED DEVICE TO PACIFIC TECHNOLOGY WHICH IS LOCATED IN ANTIOCH, CA. FOR EVALUATION.


Power Reactor
Event Number: 36087
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: JENKINS
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/30/1999
Notification Time: 03:50 [ET]
Event Date: 08/30/1999
Event Time: 02:35 [EDT]
Last Update Date: 08/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
SCOTT SPARKS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Hot Shutdown 0 Hot Shutdown
2 N N 0 Hot Shutdown 0 Hot Shutdown
Event Text
THE LICENSEE PLANS TO NOTIFY THE STATE OF NORTH CAROLINA THAT THEY MAY HAVE VIOLATED THEIR NPDES (NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM) PERMIT. (Refer to event numbers 36084 and 36086 for related events.)

PLANT OPERATORS OPENED THE SITE STORM DRAIN COLLECTOR BASIN DISCHARGE VALVES TO THE CIRCULATING WATER DISCHARGE CANAL. THESE VALVES BYPASS THE NORMAL PATH TO THE STABILIZATION POND AND CONSTITUTE A POTENTIAL UNMONITORED RADIOACTIVE LIQUID RELEASE. THESE VALVES WERE OPENED DUE TO THE EXCESSIVE RAIN ASSOCIATED WITH HURRICANE DENNIS, AND THEY WILL BE CLOSED WHEN THE RAIN SUBSIDES. THIS CONDITION REQUIRES THE LICENSEE TO NOTIFY THE STATE BECAUSE OF THEIR NPDES PERMIT.

THE NRC RESIDENT INSPECTOR WAS NOTIFIED BY THE LICENSEE.


General Information or Other
Event Number: 36088
Rep Org: STATE OF MISSISSIPPI
Licensee: BOND PAVING COMPANY, INC.
Region: 2
City: GULFPORT   State: MS
County:
License #: MS638-01
Agreement: Y
Docket:
NRC Notified By: ROBERT NELSON
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/30/1999
Notification Time: 09:09 [ET]
Event Date: 08/30/1999
Event Time: 08:00 [CDT]
Last Update Date: 09/03/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
SCOTT SPARKS (R2)
JOHN HICKEY (NMSS)
Event Text
AGREEMENT STATE REPORT OF A TROXLER GAUGE STOLEN FROM BOND PAVING COMPANY, INC., LOCATED IN GULFPORT, MISSISSIPPI

At approximately 0800 CDT on 08/30/99, Bond Paving Company, Inc. (located in Gulfport, Mississippi) notified the State of Mississippi, Division of Radiological Health, of a stolen Troxler gauge. Apparently, the gauge (which was inside its storage container) was stolen some time over the weekend along with a truck and some computer equipment. The gauge (model number 3440, serial number 28210) contained 8 mCi of cesium-137 (serial number 750-2160) and 40 mCi of americium-241/beryllium (serial number 47-2489).

The licensee notified the local police department.

(Call the NRC operations officer for a state contact telephone number and the address of the licensee.)

*** UPDATE FROM NELSON TO POERTNER AT 1436 EDT ON 9/3/99 ***

Troxler gauge was found approximately 1/2 mile from the location from which it was stolen.

NOTIFIED R2DO (LANDIS), NMSS (HICKEY).


Power Reactor
Event Number: 36089
Facility: HATCH
Region: 2     State: GA
Unit: [1] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: BUTLER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/30/1999
Notification Time: 09:57 [ET]
Event Date: 08/30/1999
Event Time: 09:32 [EDT]
Last Update Date: 08/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
SCOTT SPARKS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 98 Power Operation 98 Power Operation
Event Text
THE PLANT LOST PRIMARY AND BACKUP NOAA WEATHER RADIO SYSTEM

THE PLANT WAS NOTIFIED AT 0932 THAT BOTH PRIMARY AND BACKUP NOAA WEATHER RADIO SIGNALS WERE LOST. THE SIGNAL CAME BACK WHILE SECURITY WAS ATTEMPTING TO RESTORE IT, BUT THE CAUSE OF THE PROBLEM WAS NOT DETERMINED AND AN INVESTIGATION IS ONGOING. THE RADIO WAS OUT OF SERVICE FROM 0932 TO 0950 AND IS CURRENTLY STILL OPERABLE.

THE RESIDENT INSPECTOR WILL BE INFORMED AND THE STATE HAS BEEN NOTIFIED


Power Reactor
Event Number: 36090
Facility: HARRIS
Region: 2     State: NC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: ABELL
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/30/1999
Notification Time: 11:12 [ET]
Event Date: 08/30/1999
Event Time: 10:52 [EDT]
Last Update Date: 08/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
Person (Organization):
SCOTT SPARKS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
LOSS OF OPERABILITY OF SEVEN EMERGENCY SIRENS IN HARNETT COUNTY, N.C.

THE PLANT DISCOVERED THE ABILITY TO ACTIVATE THE SEVEN PUBLIC WARNING SIRENS IN HARNETT COUNTY, N.C. WAS LOST FOR A PERIOD OF TEN MINUTES (FROM 0730-0740 @ 8/30/99). THIS WAS DUE TO ELECTRICAL POWER BEING LOST TO BOTH THE PRIMARY AND BACKUP REPEATER TOWERS BECAUSE OF SEVERE WEATHER. ALTERNATE POWER WAS ESTABLISHED AT 0740 AND THE PRIMARY REPEATER WAS RETURNED TO SERVICE AT 0900.

THE RESIDENT INSPECTOR WAS NOTIFIED.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 36091
Facility: COOPER
Region: 4     State: NE
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: GREEN
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/31/1999
Notification Time: 02:21 [ET]
Event Date: 08/30/1999
Event Time: 22:22 [CDT]
Last Update Date: 09/21/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
CHARLES CAIN (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
FAILURE OF A SINGLE TRAIN SYSTEM THAT IS REQUIRED TO MITIGATE THE CONSEQUENCES OF AN ACCIDENT

On 8/30/99 at 2222 while performing maintenance on SW-MOV-650MV, Reactor Equipment Cooling (REC) heat exchanger "A" Service Water (SW) Outlet Valve, SW-MOV-650MV was manually opened while disconnecting Limit Switches. The valve was opened to a point that allowed 2475 Gallons Per Minute (GPM) of service water flow thru the "A" REC heat exchanger. Service water flow greater than 1200 GPM thru the "A" REC heat exchanger results in the "A" Service Water subsystem being inoperable (LCO 3.7.2) which requires restoration of the "A" Service Water subsystem within 30 days. LCO 3.8.1 was entered for Diesel Generator 1 (DG1) because it was declared inoperable due to the Service Water being inoperable. The Control Room Emergency Filtration System (CREFS), which is a single train system, was aligned to a bus that would be powered from DG1 in the event of an accident. This condition resulted in CREFS also being declared inoperable (LCO 3.7.4)

When the increased flow though the "A" REC heat exchanger was discovered by a Control Room Operator, the Valve Technicians performing the maintenance were instructed to manually close SW-MOV-650MV until Service Water flow through the "A" REC Heat Exchanger was reduced below 1200 GPM, which was completed at 2238. All of the previously mentioned LCO's were also exited at this time. At the time this event occurred both sources of offsite power were available and DG2 was determined to not be affected by this condition.

The Resident Inspector was notified.

*** UPDATE ON 9/21/99 @ 0259 BY GREEN TO GOULD *** EVENT RETRACTION

SUBSEQUENT INVESTIGATION HAS DETERMINED THAT D/G#1 WAS ALWAYS CAPABLE OF PERFORMING ITS SAFETY FUNCTION DURING THE EVENT. THEREFORE, CREFS REMAINED OPERABLE AND THIS EVENT IS BEING RETRACTED.

THE RESIDENT INSPECTOR WAS NOTIFIED. REG 4 RDO(TAPIA) WAS INFORMED


Fuel Cycle Facility
Event Number: 36092
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: SISLER
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 08/31/1999
Notification Time: 07:17 [ET]
Event Date: 08/30/1999
Event Time: 16:00 [EDT]
Last Update Date: 08/31/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2) - SAFETY EQUIPMENT FAILURE
Person (Organization):
DAVID HILLS (R3)
JOSEPHINE PICCONE (NMSS)
Event Text
INSUFFICIENT SMOKE-HEAD COVERAGE

AT 1510 ON 8/30/99, THE PLANT SHIFT SUPERINTENDENT WAS NOTIFIED BY THE CADP (CASCADE AUTOMATIC DATA PROCESSING) SYSTEM ENGINEER FOLLOWING AN INVESTIGATION OF A PROBLEM WITH THE 33-8 MIMIC PANEL LIGHTS AND THE CADP COMPUTER, THAT BETWEEN 2200, 8/27/99 AND 0700, 8/28/99 INSUFFICIENT SMOKE-HEAD COVERAGE WAS AVAILABLE AT THE LAW STATION. TSR SECTION 2.5.3.3 "UF6 SMOKE DETECTION" REQUIRES SMOKE-HEAD COVERAGE WHEN OPERATING IN MODES II. III, IV (THEY WERE OPERATING IN MODE III). DURING THE STATED TIME PERIOD THE LAW STATION WAS OPERATED ABOVE ATMOSPHERIC PRESSURE, AND A CONTINUOUS SMOKE-WATCH WAS NOT STATIONED.

THIS CONDITION IS REPORTABLE TO THE NRC PER CFR 76.120(c) SAFETY EQUIPMENT FAILURE/ACTUATION. THE EQUIPMENT IS REQUIRED BY A TSR TO BE AVAILABLE AND OPERABLE AND NO REDUNDANT EQUIPMENT IS AVAILABLE AND OPERABLE TO PERFORM THE REQUIRED SAFETY FUNCTION.

THE RESIDENT INSPECTOR WAS NOTIFIED ALONG WITH THE DOE REPRESENTATIVE.