Event Notification Report for August 16, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
08/15/1999 - 08/16/1999
EVENT NUMBERS
36033
Other Nuclear Material
Event Number: 36033
Rep Org: U.S. ARMY
Licensee: U.S. ARMY
Region: 3
City: Rock Island State: IL
County:
License #: 12-00722-06
Agreement: Y
Docket:
NRC Notified By: GAVIN ZIEGLER
HQ OPS Officer: LEIGH TROCINE
Licensee: U.S. ARMY
Region: 3
City: Rock Island State: IL
County:
License #: 12-00722-06
Agreement: Y
Docket:
NRC Notified By: GAVIN ZIEGLER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/16/1999
Notification Time: 17:04 [ET]
Event Date: 08/16/1999
Event Time: 00:00 [CDT]
Last Update Date: 08/16/1999
Notification Time: 17:04 [ET]
Event Date: 08/16/1999
Event Time: 00:00 [CDT]
Last Update Date: 08/16/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(1) - UNPLANNED CONTAMINATION
10 CFR Section:
30.50(b)(1) - UNPLANNED CONTAMINATION
Person (Organization):
BRENT CLAYTON (R3)
PETER ESELGROTH (R1)
JOHN HICKEY (NMSS)
BRENT CLAYTON (R3)
PETER ESELGROTH (R1)
JOHN HICKEY (NMSS)
UNPLANNED CONTAMINATION IN AN ARMS ROOM AT FORT DRUM (A U.S. ARMY FACILITY) LOCATED IN WATERTOWN, NEW YORK
At 1400 EDT on 08/12/99, individuals located in an arms room were performing maintenance on an M224 mortar range indicator when one of the four sources broke causing an unplanned contamination. The sources each contained 0.8 Ci of tritium. Two individuals were close by, and two bioassays were performed. The bioassay results are currently pending. However, the following wipe test results were received today (08/16/99):
6,300,000 dpm at the site of the broken source,
1,358,000 dpm on the mortar housing,
31,000 dpm on the mortar,
74,000 dpm on an adjacent table top,
74,000 dpm (highest reading) on a wall, and
34,000 - 35,000 dpm on four walls.
It was also reported that the maintenance activities should have occurred in a maintenance shop rather than in the arms room (which is used for storage). As a result, there may be additional items with contamination. The arms room has been cordoned off.
(Call the NRC operations officer for a contact telephone number.)
At 1400 EDT on 08/12/99, individuals located in an arms room were performing maintenance on an M224 mortar range indicator when one of the four sources broke causing an unplanned contamination. The sources each contained 0.8 Ci of tritium. Two individuals were close by, and two bioassays were performed. The bioassay results are currently pending. However, the following wipe test results were received today (08/16/99):
6,300,000 dpm at the site of the broken source,
1,358,000 dpm on the mortar housing,
31,000 dpm on the mortar,
74,000 dpm on an adjacent table top,
74,000 dpm (highest reading) on a wall, and
34,000 - 35,000 dpm on four walls.
It was also reported that the maintenance activities should have occurred in a maintenance shop rather than in the arms room (which is used for storage). As a result, there may be additional items with contamination. The arms room has been cordoned off.
(Call the NRC operations officer for a contact telephone number.)