Event Notification Report for August 09, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/08/1999 - 08/09/1999

EVENT NUMBERS
3600936010

Power Reactor
Event Number: 36009
Facility: INDIAN POINT
Region: 1     State: NY
Unit: [] [3] []
RX Type: [2] W-4-LP,[3] W-4-LP
NRC Notified By: TOM McKEE
HQ OPS Officer: STEVE SANDIN
Notification Date: 08/09/1999
Notification Time: 12:15 [ET]
Event Date: 08/09/1999
Event Time: 10:30 [EDT]
Last Update Date: 08/09/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
HAROLD GRAY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
LICENSEE NOTIFIED NEW YORK STATE OF MINOR SEWAGE SPILL TO HUDSON RIVER

"THE NYS DEPARTMENT OF ENVIRONMENTAL CONSERVATION WAS NOTIFIED OF A SEWAGE SPILL FROM THE WAREHOUSE SEWAGE PIT INTO A STORM DRAIN (AND THUS TO THE HUDSON RIVER). THE EXACT QUANTITY OF LEAKAGE WAS UNKNOWN, THE LEAKAGE LASTED APPROXIMATELY 20 MINUTES. [REFERENCE] DER 99-1603."

THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.


Fuel Cycle Facility
Event Number: 36010
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: RICK LARSON
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 08/10/1999
Notification Time: 09:49 [ET]
Event Date: 08/09/1999
Event Time: 11:30 [EDT]
Last Update Date: 08/12/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
BRUCE BURGESS (R3)
DON COOL (NMSS)
Event Text
NRC BULLETIN 91-01 RESPONSE (24-HOUR REPORT)

Operations personnel during a walkdown of the seal exhaust system discovered that a nuclear criticality safety approval (NCSA) requirement, maximum oil volume, could not be verified when an oil level was observed in the pumps separator's sight glass. The pumps in question were used for the highly enriched uranium program, and after it's suspension, prior to March 1997, the pumps were placed out of service. Visible oil level in the sight glass without supporting documentation for oil capacity of these pumps constitutes a loss of one control (Volume) for double contingency. The second control (Interaction) was maintained.

There was no loss of hazardous/radioactive material or radioactive/radiological contamination exposure as a result of this event.

Portsmouth personnel notified the NRC Resident Inspector and the DOE Site Representative.


* * * UPDATE AT 0130 ON 08/12/99 BY SPAETH TO GOULD * * *

WALKDOWNS OF SEAL EXHAUST PUMPS IN THE X-326 BUILDING REVEALED THAT SEVERAL OLD STYLE/OUT OF SERVICE PUMPS (KDH-80, DVD-8810) HAD INDICATION OF OIL IN THE SEPARATOR SITE GLASS, ABOVE THE LEVEL OF THE OVERFLOW. THIS IS A LOSS OF ONE CONTROL (VOLUME) OF THE DOUBLE CONTINGENCY PRINCIPLE. THE SECOND CONTROL (INTERACTION) REMAINS IN PLACE. THIS UPDATE IS BEING SUBMITTED TO IDENTIFY THE FACT THAT ADDITIONAL PUMPS WERE IDENTIFIED IN WHICH THE MAXIMUM AMOUNT OF OIL COULD NOT BE VERIFIED.

PORTSMOUTH PERSONNEL NOTIFIED THE NRC RESIDENT INSPECTOR AND DOE SITE REPRESENTATIVE.

THE NRC OPERATIONS OFFICER NOTIFIED R3DO (BURGESS) AND NMSS EO (HICKEY).


* * * UPDATE AT 0811 ON 08/13/99 BY CASTLE TO GOULD * * *

X-326 BUILDING FOLLOW-UP WALKDOWNS OF SEAL EXHAUST PUMPS REVEALED THAT NCSA 0326_0914.A01 REQUIREMENT #6 WAS NOT PERFORMED FOR THE OLD STYLE/OUT OF SERVICE PUMPS (KDH-80, DVD-8810). REQUIREMENT #5 STATES "OIL OVERFLOW LINES SHALL BE CHECKED SEMIANNUALLY TO VERIFY OPERATION (i.e., CLARITY CHECK)." THIS IS A LOSS OF ONE CONTROL (VOLUME) OF THE DOUBLE CONTINGENCY PRINCIPLE. THE SECOND CONTROL (INTERACTION) REMAINS IN PLACE.

CRITICALITY COULD OCCUR IF THE PUMPS AND SEPARATORS ARE FULLY LOADED WITH AN OPTIMALLY MODERATED UF6 AND OIL MIXTURE AND MULTIPLE SPACING VIOLATIONS OCCUR WITH OTHER URANIUM BEARING MATERIAL.

VOLUME CONTROL WAS NOT MET, BUT WAS STILL WITHIN THE BOUNDS OF NCSA 0326_014.E01 EVALUATION.

NCS ENGINEERS DETERMINED THE VOLUME OF OIL IN EACH PUMP WAS LESS THAN 1.125 GALLONS. AS OF 2000, ALL OLD STYLE/OUT OF SERVICE PUMPS HAD BEEN DRAINED OF OIL.

PORTSMOUTH PERSONNEL NOTIFIED THE NRC RESIDENT INSPECTOR.

THE NRC OPERATIONS OFFICER NOTIFIED R3DO (BURGESS) AND NMSS EO (PICCONE).