Event Notification Report for August 05, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
08/04/1999 - 08/05/1999

EVENT NUMBERS
3600435992359933599435995

Other Nuclear Material
Event Number: 36004
Rep Org: WASHINGTON HOSPITAL CENTER
Licensee: WASHINGTON HOSPITAL CENTER
Region: 1
City: Washington   State: DC
County:
License #: SNM-1446
Agreement: N
Docket:
NRC Notified By: DR. BASS, JOHN GLENN
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/06/1999
Notification Time: 16:41 [ET]
Event Date: 08/05/1999
Event Time: 17:00 [EDT]
Last Update Date: 08/06/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
RICHARD BARKLEY (R1)
SUSAN SHANKMAN (NMSS)
Event Text
EXPLANT OF AN IMPLANTED NUCLEAR-POWERED CARDIAC PACEMAKER FOLLOWING DEATH OF A PATIENT

A representative from the Washington Hospital Center located in Washington D.C. reported the explant of an implanted nuclear-powered cardiac pacemaker due to death of the patient at Georgetown Medical Center located in Washington D.C. The patient passed away on 08/05/99, and Washington Hospital Center was notified at approximately 1700 on 08/06/99. The cause of death was unknown, but it was reported that the pacemaker was not the cause of death. The pacemaker has been explanted and has been in secure storage at Washington Hospital Center since this afternoon (08/06/99).

The pacemaker contains 2.8 curies of Plutonium-238 (approximately 175 milligrams). It was manufactured by Cordis model OMNI Stancor (model #184A, serial #586).

The licensee has contacted the manufacturer and plans to ship the pacemaker to the manufacturer for proper disposal. The licensee also notified the NRC Region 1 office (Jim Dwyer).

(Call the NRC operations officer for a site contact telephone number and address.)


Power Reactor
Event Number: 35992
Facility: PILGRIM
Region: 1     State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: JOHN HOUSE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/05/1999
Notification Time: 12:45 [ET]
Event Date: 08/05/1999
Event Time: 09:47 [EDT]
Last Update Date: 08/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
RICHARD BARKLEY (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC REACTOR SCRAM DUE TO A MAIN TURBINE TRIP ON MOISTURE SEPARATOR HIGH LEVEL DUE TO A CONTROLLER MALFUNCTION

At 0947, the unit automatically scrammed from 100% power due to a main turbine trip. All control rods fully inserted. The main turbine trip resulted from moisture separator high level due to a controller malfunction. Following the reactor scram, reactor pressure vessel level decreased to less than 12", and preliminary investigations have shown that all required engineered safety feature (ESF) actuations functioned as expected. The ESF actuations included a full reactor scram, the scram function of the hydraulic control units, a reactor building isolation, a standby gas treatment system initiation, a Group II (miscellaneous containment) isolation, and a Group VI (reactor water cleanup) isolation. The licensee is still investigating this event, but stated that there may have been a momentary safety relief valve actuation on the main turbine trip. The safety relief valve is closed at this time.

The only problem following the scram was that the 'C' source range monitor would not drive into the core. This was the result of a blown fuse, and it has been rectified.

The unit is currently stable in Hot Shutdown. Steam is being dumped to the main condenser, and normal feedwater is supplying water to the reactor vessel. The recirculation pumps are operating. There were no unusual radiological releases during or after this event, and there were no safety injections or emergency core cooling system actuations. There was no loss of offsite power, and there were no emergency diesel generator actuations.

The licensee notified the NRC resident inspector and plans to notify the state tomorrow.


Power Reactor
Event Number: 35993
Facility: PRAIRIE ISLAND
Region: 3     State: MN
Unit: [1] [2] []
RX Type: [1] W-2-LP,[2] W-2-LP
NRC Notified By: BRAD ELLISON
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/05/1999
Notification Time: 14:54 [ET]
Event Date: 08/05/1999
Event Time: 12:50 [CDT]
Last Update Date: 08/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
MARK RING (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
INOPERABILITY OF BOTH CONTROL ROOM SPECIAL VENTILATION SYSTEM TRAINS DUE TO A BROKEN DOOR LATCH MECHANISM

At 1250 CDT, door 158 (the entry door to the 122 control room/chiller room) was identified as having a broken latch mechanism, and the broken latch resulted in a breech of the control room special ventilation system such that both trains were considered to be inoperable. Door 158 was returned to an operable status at 1335 CDT (45 minutes after discovery of the problem) following maintenance repairs on the latch mechanism. Therefore, the 1-hour limiting condition for operation action statement for Technical Specification 3.13.a.1 was met.

The licensee notified the NRC resident inspector.


Power Reactor
Event Number: 35994
Facility: WOLF CREEK
Region: 4     State: KS
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: SHANE FERGUSON
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/05/1999
Notification Time: 15:32 [ET]
Event Date: 08/05/1999
Event Time: 12:58 [CDT]
Last Update Date: 08/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
TOM STETKA (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 100 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP DUE TO CLOSURE OF THE 'D' STEAM GENERATOR FEEDWATER REGULATION VALVE

At 1258 CDT, an automatic reactor trip occurred due to the failure of the 'D' steam generator feedwater regulation valve. The valve failed closed, and steam generator level decreased to the reactor trip setpoint of 23%. The minimum steam generator level was approximately 20%. The unit also received a feedwater isolation and auxiliary feedwater actuation (both motor-driven and turbine-driven) due to the low-low steam generator levels. The licensee stated that these were expected for this event. All control rods fully inserted, and all safety equipment performed as designed. One cooldown steam dump valve failed to fully close, and it was isolated to allow automatic control of reactor coolant system (RCS) temperature using the remaining cooldown valves. The licensee stated that there was not an excessive cooldown and that RCS temperature decreased to 553 °F. None of the primary safety relief valves lifted. Secondary (atmospheric) relief valves lifted and reseated, and there has been no history of steam generator tube leakage. There were no radiological releases.

The licensee's investigation is currently in progress, and it is currently believed that the valve failure may have been the result of an electronic problem. The controller for this valve had a 0% output while the others had 100% output. There were no maintenance or surveillance activities associated with the 'D' steam generator feedwater regulation valve ongoing at the time of the event. The licensee stated that there was nothing that was unusual or not understood.

The unit is currently stable in Hot Standby with the RCS at approximately 559 °F and 2,235 psi, steam generator levels at approximately 40%, and pressurizer level at 28%. Normal charging and letdown, pressurizer heaters and sprays, and the reactor coolant pumps are being utilized for primary system level, pressure, and transport control. Secondary steam is being dumped to the main condenser, and auxiliary feedwater is supplying water to the steam generators. Grid stability is good, and all normal power feeds are available.

The licensee notified the NRC resident inspector and the applicable state and county agencies.

***************** UPDATE AT 1749 EDT ON 08/05/99 FROM SHANE FERGUSON TO TROCINE *****************

The licensee plans to issue a media/press release. The cause of the problem was identified to be a failed valve controller circuitry card. The unit may be restarted as early as tonight between 2100 CDT and 2200 CDT.

The licensee plans to notify the NRC resident inspector. The NRC operations officer notified the R4DOs (Stetka and Pellet).


Fuel Cycle Facility
Event Number: 35995
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: RON CRABTREE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 08/05/1999
Notification Time: 20:22 [ET]
Event Date: 08/05/1999
Event Time: 17:38 [EDT]
Last Update Date: 08/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MARK RING (R3)
SUSAN SHANKMAN (NMSS)
CHARLES MILLER (IRO)
Event Text
NOTIFICATION TO ANOTHER GOVERNMENT AGENCY (4-HOUR REPORT)

The following text is a portion of a facsimile received from Portsmouth:

"At 1738 hours on 08/05/99, it was determined that a Nuclear Criticality Safety Approval (NCSA) requirement was violated in the X-705 West Annex which is a Department of Energy (DOE) regulated area of the PORTS site. This event was reportable to DOE as a loss of one (1) NCSA control. This notification to another government agency is reportable to the NRC as a 4-hour notification report."

Portsmouth personnel notified the NRC resident inspector and the DOE site representative.