Event Notification Report for July 25, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
07/24/1999 - 07/25/1999

EVENT NUMBERS
35958

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35958
Facility: LASALLE
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: WILLIAMS
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 07/25/1999
Notification Time: 22:32 [ET]
Event Date: 07/25/1999
Event Time: 20:21 [CDT]
Last Update Date: 07/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(A) - UNANALYZED COND OP
Person (Organization):
PATRICK HILAND (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 87 Power Operation 87 Power Operation
Event Text
PLANT ENTERED TECH SPEC 3.2.3 LCO ACTION STATEMENT

AT 2021 CDT ON 07/25/99, THE "1B21-N500" PRESSURE TRANSMITTER INDICATION DROPPED FROM 1000 PSIG TO INDICATED 600 PSIG REACTOR PRESSURE. THIS TRANSMITTER IS THE PRIMARY PRESSURE TRANSMITTER TO THE ELECTROHYDRAULIC CONTROL (EHC) SYSTEM. DUE TO THIS CHANGE IN PRESSURE INDICATION, THE BACKUP TRANSMITTER TOOK CONTROL. IN THIS LINEUP (BACKUP TRANSMITTER IN CONTROL OF THE EHC SYSTEM), THERE IS NO OTHER BACKUP TRANSMITTER AVAILABLE AND PROCEDURE "LOA-EH-101" STATES THAT THIS CONDITION IS AN UNANALYZED CONDITION AND THE PLANT IS TO ENTER TS 3.2.3. TS 3.2.3 REQUIRES THE REACTOR TO BE <25% POWER WITHIN 4 HOURS. THIS CONDITION WAS NOT DETERMINED TO BE AN UNANALYZED CONDITION UNTIL 2045 CDT ON 07/25/99 UTILIZING THE ABOVE PROCEDURE AND THE UFSAR. THE PROBLEM WITH THE TRANSMITTER IS BEING INVESTIGATED TO DETERMINE WHY IT DOES NOT INDICATE 1000 PSIG.

THE LICENSEE WILL INFORM THE NRC RESIDENT INSPECTOR.

* * * RETRACTION AT 2253 ON 07/29/99 FROM GRANWALD TO STRANSKY * * *

"It was subsequently determined from a detailed evaluation that was performed in May, 1999, which clearly shows that operation with a pressure regulator out of service at LaSalle is bounded by the thermal limits calculated for the slow closure of one or more turbine control valves (TCVs). The use of the thermal limits reported in the LaSalle Unit 1 Cycle 8 Core Operating Limits Report for the slow closure of one or more TCVs for operations with a pressure regulator out of service does not result in operation of the plant in an unanalyzed condition. The thermal limits were adjusted to be in line with the TCV slow closure analysis and plant thermal limits were declared operable and Tech Spec 3.2.3 exited within 4 hours. Therefore, LaSalle Unit 1 was not in an unanalyzed condition as reported in Event No. 35958."

The licensee will notify the NRC resident inspector and the NRC Operations Officer notified the R3DO Wright.