Event Number: 35874
Facility: HATCH
Region: 2     State: GA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: FRANK GORLEY
HQ OPS Officer: DOUG WEAVER
Notification Date: 06/28/1999
Notification Time: 03:55 [ET]
Event Date: 06/28/1999
Event Time: 03:00 [EDT]
Last Update Date: 06/28/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION 50.72(b)(1)(iv) - ECCS INJECTION
Person (Organization):
AL BELISLE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 100 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC REACTOR SCRAM ON LOW REACTOR WATER LEVEL

The reactor automatically scrammed on low reactor vessel water level because of maintenance activities on the 'B' level keep fill system. Operators venting the keep fill system unintentionally vented the 'B' reference leg because the isolation valve between the two systems is apparently leaking. This venting caused level instruments using the 'B' reference leg to indicate high. The mismatch on level indicators caused the feed system to switch to the 'B' leg (which happened to be the failed system). This resulted in a decrease in feed flow and an actual decrease in reactor vessel water level.

The decrease in reactor water level caused a reactor scram and High Pressure Coolant Injection (HPCI) initiation. Reactor Core Isolation Cooling (RCIC) did not initiate because it uses the 'B' reference leg as an input.
All control rods fully inserted. The plant is stable in mode 3. Water level has been restored to the normal band and is being maintained by the feed system. The recirculating pumps are operating and no safety relief valves lifted. The lowest indicated level was -45".

The licensee notified the NRC resident inspector.


Fuel Cycle Facility
Event Number: 35875
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: JEFF CASTLE
HQ OPS Officer: BOB STRANSKY
Notification Date: 06/28/1999
Notification Time: 14:52 [ET]
Event Date: 06/28/1999
Event Time: 01:05 [EDT]
Last Update Date: 06/28/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MIKE JORDAN (R3)
DON COOL (NMSS)
Event Text
LICENSEE 24 HOUR REPORT - CRANE STOPPED WHILE MOVING UF6 CYLINDER

"On June 28, 1999 at approximately 0105, the X-343 south crane movement stopped completely and would not operate in any direction. The crane failed while a full liquid UF6 cylinder was being removed from autoclave #6. The crane brakes functioned as designed to prevent further movement of the UF6 cylinder. Following failure of the crane, the UF6 cylinder was suspended approximately two feet above the autoclave rollers. The exact cause of the crane movement failure is currently under investigation. The actuation of the crane brake is believed to have been necessary as a result of the opening of the thermal overloads. Pending further investigation of the cause for the brake actuation, the brake actuation is being considered a valid safety system actuation, and reportable in accordance with SAR Table 6.9, Criterion J2. As a precautionary measure, all liquid UF6 handling cranes have been tagged out of service pending the noted investigation. Support cradles have been positioned to support the suspended liquid UF6 cylinder."

The NRC resident inspector has been informed of this event.


Power Reactor
Event Number: 35877
Facility: WASHINGTON NUCLEAR
Region: 4     State: WA
Unit: [2] [] []
RX Type: [2] GE-5
NRC Notified By: BRIAN GARDES
HQ OPS Officer: BOB STRANSKY
Notification Date: 06/28/1999
Notification Time: 19:29 [ET]
Event Date: 06/28/1999
Event Time: 12:44 [PDT]
Last Update Date: 06/28/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
LINDA SMITH (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
AUTOMATIC CLOSURE OF MSIVs

The licensee reported that the main steam isolation valves (MSIVs) automatically closed due to unknown reasons.; however, surveillance procedure ESP-RPS-X301 (Turbine Throttle Valves Channel Check) was being performed at the time. The unit is currently in Cold Shutdown for a fuel savings dispatch.

The NRC resident inspector has been informed of this notification by the licensee.


Power Reactor
Event Number: 35878
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: DAVE JESTER
HQ OPS Officer: BOB STRANSKY
Notification Date: 06/28/1999
Notification Time: 21:43 [ET]
Event Date: 06/28/1999
Event Time: 18:42 [EDT]
Last Update Date: 06/28/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
AL BELISLE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 70 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC TURBINE TRIP/REACTOR SCRAM DUE TO LOSS OF CONDENSER VACUUM

At 1842 EDT, an automatic turbine trip/reactor scram occurred due to low condenser vacuum after all four circulating water pumps tripped. All control rods inserted following the scram, and the main steam isolation valves (MSIVs) remained open. No safety/relief valves lifted during the event. All systems functioned as expected with primary containment isolation system (PCIS) Group 2 (drywell floor and equipment drains), Group 6 (containment atmosphere cooling) and Group 8 (RHR shutdown cooling) isolations occurring due to low reactor vessel water level following the scram. The scram signal was reset at 1850 EDT.

The unit is currently stable in Hot Shutdown. Reactor vessel pressure is being controlled using the main turbine bypass valves. The licensee has restored circulating water system flow to the main condenser.

The licensee reported that the circulating water pumps tripped as a result of excessive differential pressure across the intake screens caused by a fish run in the intake canal. Operators had manually reduced power from 100% prior to the event in an attempt to stabilize condenser vacuum. Unit 1 experienced similar increased differential pressure in the circulating water system, but were able to stabilize condenser vacuum after reducing power to 70%. The fish run has subsided, and the licensee is currently returning Unit 1 to 100% or rated power.

The NRC resident inspector has been informed of this event by the licensee.