Event Notification Report for June 17, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
06/16/1999 - 06/17/1999
EVENT NUMBERS
35835358363583835839358403584135921
Power Reactor
Event Number: 35835
Facility: GINNA
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DOUGLAS PETERSON
HQ OPS Officer: DOUG WEAVER
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DOUGLAS PETERSON
HQ OPS Officer: DOUG WEAVER
Notification Date: 06/17/1999
Notification Time: 09:06 [ET]
Event Date: 06/17/1999
Event Time: 08:26 [EDT]
Last Update Date: 06/17/1999
Notification Time: 09:06 [ET]
Event Date: 06/17/1999
Event Time: 08:26 [EDT]
Last Update Date: 06/17/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
JIMI YEROKUN (R1)
JIMI YEROKUN (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
A CONTRACTOR HAD HIS SITE ACCESS REVOKED DUE TO A DISCOVERY MADE RELATING TO HIS PREVIOUS WORK HISTORY. THE LICENSEE WILL NOTIFY THE NRC RESIDENT INSPECTOR.
Power Reactor
Event Number: 35836
Facility: LIMERICK
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: PETER GARDNER
HQ OPS Officer: WILLIAM POERTNER
Region: 1 State: PA
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: PETER GARDNER
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 06/17/1999
Notification Time: 12:01 [ET]
Event Date: 06/17/1999
Event Time: 10:15 [EDT]
Last Update Date: 06/17/1999
Notification Time: 12:01 [ET]
Event Date: 06/17/1999
Event Time: 10:15 [EDT]
Last Update Date: 06/17/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
JIMI YEROKUN (R1)
JIMI YEROKUN (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
INADVERTENT ESF ACTUATION.
During preparations for overspeed surveillance testing of the D23 diesel generator an inadvertent 'C' emergency service water pump start signal was received causing the pump to start. The cause of the event was personnel error by an I&C technician during installation of a speed signal generator. The speed tachometer was being calibrated and was set at 900 rpm when the speed signal generator used for overspeed testing was hooked up. Normally the calibration would be complete and the signal generator set at zero rpm prior to hookup. All systems responded as expected.
The NRC resident inspector was notified.
During preparations for overspeed surveillance testing of the D23 diesel generator an inadvertent 'C' emergency service water pump start signal was received causing the pump to start. The cause of the event was personnel error by an I&C technician during installation of a speed signal generator. The speed tachometer was being calibrated and was set at 900 rpm when the speed signal generator used for overspeed testing was hooked up. Normally the calibration would be complete and the signal generator set at zero rpm prior to hookup. All systems responded as expected.
The NRC resident inspector was notified.
Power Reactor
Event Number: 35838
Facility: BROWNS FERRY
Region: 2 State: AL
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: DON SMITH
HQ OPS Officer: WILLIAM POERTNER
Region: 2 State: AL
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4,[3] GE-4
NRC Notified By: DON SMITH
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 06/17/1999
Notification Time: 17:27 [ET]
Event Date: 06/17/1999
Event Time: 13:37 [CDT]
Last Update Date: 06/17/1999
Notification Time: 17:27 [ET]
Event Date: 06/17/1999
Event Time: 13:37 [CDT]
Last Update Date: 06/17/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION 50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION 50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
CAUDLE JULIAN (R2)
CAUDLE JULIAN (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
INADVERTENT ESF ACTUATION.
During the performance of a scheduled surveillance 2-SR-3.3.5.1.2(ATU C)/Core and Containment Cooling Systems Analog Trip Unit Functional Test, Relay 2-RLY-073-23A-K36 was required to have inhibits (boots) installed to prevent HPCI valves (PCIS GP-4 isolation) from actuating due to a simulated high steam flow condition. At 1337 CDT on June 17, 1999, Unit 2 received a group 4 HPCI isolation during the performance of step 7.15.15 of the surveillance procedure. The licensee determined that the wrong contacts had been inhibited allowing the actuation to occur. The inhibits were removed and the PCIS GP-4 isolation was reset at 1402 CDT returning HPCI to an operable condition.
The licensee notified the NRC resident inspector.
During the performance of a scheduled surveillance 2-SR-3.3.5.1.2(ATU C)/Core and Containment Cooling Systems Analog Trip Unit Functional Test, Relay 2-RLY-073-23A-K36 was required to have inhibits (boots) installed to prevent HPCI valves (PCIS GP-4 isolation) from actuating due to a simulated high steam flow condition. At 1337 CDT on June 17, 1999, Unit 2 received a group 4 HPCI isolation during the performance of step 7.15.15 of the surveillance procedure. The licensee determined that the wrong contacts had been inhibited allowing the actuation to occur. The inhibits were removed and the PCIS GP-4 isolation was reset at 1402 CDT returning HPCI to an operable condition.
The licensee notified the NRC resident inspector.
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35839
Facility: PILGRIM
Region: 1 State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: G FIEDLER
HQ OPS Officer: WILLIAM POERTNER
Region: 1 State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: G FIEDLER
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 06/17/1999
Notification Time: 18:16 [ET]
Event Date: 06/17/1999
Event Time: 16:30 [EDT]
Last Update Date: 07/09/1999
Notification Time: 18:16 [ET]
Event Date: 06/17/1999
Event Time: 16:30 [EDT]
Last Update Date: 07/09/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
JIMI YEROKUN (R1)
JIMI YEROKUN (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Refueling | 0 | Refueling |
THREE OF FOUR MAIN STEAM RELIEF VALVES (MSRV) CONEX CONNECTORS INSTALLED BACKWARDS.
While shutdown the licensee determined that 3 of 4 MSRV's had the conex connectors installed backwards. The connectors provide the environmental qualification seal to the pilot solenoid valve. ADS may not have functioned under elevated drywell temperature conditions.
The licensee plans to notify the NRC resident inspector.
*** RETRACTION OF EVENT AT 1120 ON 7/9/99 RECEIVED BY POERTNER ***
Further engineering review has determined that the valves would have operated as designed.
The licensee will notify the NRC resident inspector.
Notified R1DO (J. TRAPP).
While shutdown the licensee determined that 3 of 4 MSRV's had the conex connectors installed backwards. The connectors provide the environmental qualification seal to the pilot solenoid valve. ADS may not have functioned under elevated drywell temperature conditions.
The licensee plans to notify the NRC resident inspector.
*** RETRACTION OF EVENT AT 1120 ON 7/9/99 RECEIVED BY POERTNER ***
Further engineering review has determined that the valves would have operated as designed.
The licensee will notify the NRC resident inspector.
Notified R1DO (J. TRAPP).
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35840
Facility: LASALLE
Region: 3 State: IL
Unit: [] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: S MARIK
HQ OPS Officer: WILLIAM POERTNER
Region: 3 State: IL
Unit: [] [2] []
RX Type: [1] GE-5,[2] GE-5
NRC Notified By: S MARIK
HQ OPS Officer: WILLIAM POERTNER
Notification Date: 06/17/1999
Notification Time: 21:01 [ET]
Event Date: 06/17/1999
Event Time: 17:22 [CDT]
Last Update Date: 06/22/1999
Notification Time: 21:01 [ET]
Event Date: 06/17/1999
Event Time: 17:22 [CDT]
Last Update Date: 06/22/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
JOHN MADERA (R3)
JOHN MADERA (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
ESF ACTUATION.
At 1722 CDT the 2D primary containment vacuum breaker 2PC001D went from the closed (normal) position to an indicated dual position. The valve is actuated by a differential pressure between the suppression chamber and the drywell air space and is designed to open at 0.5 psid or less. Differential pressure at 1722 CDT was 0.23 psid. An operator was dispatched and the containment vacuum breaker was manually cycled. After being manually cycled the containment vacuum breaker returned to the closed position. The licensee subsequently satisfactorily performed an operability test on the containment vacuum breaker.
The licensee has notified the NRC resident inspector.
*** UPDATE ON 6/22/99 @ 1611 BY MARIK TO GOULD *** RETRACTION
BASED ON A REVIEW BY STATION MANAGEMENT AND CONCURRENCE FROM CORPORATE REGULATORY ASSURANCE, THE LICENSEE IS RETRACTING THIS EVENT. FOLLOWING ADDITIONAL REVIEWS OF 10CFR50.72 AND NUREG-1022 REV 1, IT HAS BEEN DETERMINED THE ACTUATION OF THE "D" CONTAINMENT VACUUM BREAKER IS AN ACTUATION OF A SINGLE COMPONENT OF THE CONTAINMENT VACUUM RELIEF SYSTEM(CVARS). THIS ACTUATION BY ITSELF WOULD NOT BE CAPABLE OF PROVIDING THE CVARS ESF DESIGN FUNCTION OF PROTECTING THE DRYWELL FLOOR AGAINST ADVERSE NEGATIVE PRESSURE DIFFERENTIALS. THEREFORE, THIS EVENT IS NOT REPORTABLE AS AN ESF ACTUATION AND ACCORDINGLY IS BEING RETRACTED.
THE RESIDENT INSPECTOR WAS NOTIFIED. REG 3 RDO (JORDAN) WAS NOTIFIED.
At 1722 CDT the 2D primary containment vacuum breaker 2PC001D went from the closed (normal) position to an indicated dual position. The valve is actuated by a differential pressure between the suppression chamber and the drywell air space and is designed to open at 0.5 psid or less. Differential pressure at 1722 CDT was 0.23 psid. An operator was dispatched and the containment vacuum breaker was manually cycled. After being manually cycled the containment vacuum breaker returned to the closed position. The licensee subsequently satisfactorily performed an operability test on the containment vacuum breaker.
The licensee has notified the NRC resident inspector.
*** UPDATE ON 6/22/99 @ 1611 BY MARIK TO GOULD *** RETRACTION
BASED ON A REVIEW BY STATION MANAGEMENT AND CONCURRENCE FROM CORPORATE REGULATORY ASSURANCE, THE LICENSEE IS RETRACTING THIS EVENT. FOLLOWING ADDITIONAL REVIEWS OF 10CFR50.72 AND NUREG-1022 REV 1, IT HAS BEEN DETERMINED THE ACTUATION OF THE "D" CONTAINMENT VACUUM BREAKER IS AN ACTUATION OF A SINGLE COMPONENT OF THE CONTAINMENT VACUUM RELIEF SYSTEM(CVARS). THIS ACTUATION BY ITSELF WOULD NOT BE CAPABLE OF PROVIDING THE CVARS ESF DESIGN FUNCTION OF PROTECTING THE DRYWELL FLOOR AGAINST ADVERSE NEGATIVE PRESSURE DIFFERENTIALS. THEREFORE, THIS EVENT IS NOT REPORTABLE AS AN ESF ACTUATION AND ACCORDINGLY IS BEING RETRACTED.
THE RESIDENT INSPECTOR WAS NOTIFIED. REG 3 RDO (JORDAN) WAS NOTIFIED.
Power Reactor
Event Number: 35841
Facility: PALISADES
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: BRUCE HOWARD
HQ OPS Officer: DOUG WEAVER
Region: 3 State: MI
Unit: [1] [] []
RX Type: [1] CE
NRC Notified By: BRUCE HOWARD
HQ OPS Officer: DOUG WEAVER
Notification Date: 06/18/1999
Notification Time: 01:41 [ET]
Event Date: 06/17/1999
Event Time: 22:40 [EDT]
Last Update Date: 06/18/1999
Notification Time: 01:41 [ET]
Event Date: 06/17/1999
Event Time: 22:40 [EDT]
Last Update Date: 06/18/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
JOHN MADERA (R3)
JOHN MADERA (R3)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
INFORMATION CALL - A FIRE ON OWNER CONTROLLED PROPERTY
A fire of undetermined origin was discovered by a janitor at 2240 on 06/17/99 in a temporary office trailer, north of the Palisades Training Building. The trailer complex is located one-half mile from the operating plant. There was no impact to the Training Building or the plant's operation, and the plant remained at full power.
The control room was notified after discovery of the blaze. The control room dispatched the plant's fire brigade and Covert Fire and Ambulance department to the scene. The plant fire brigade began immediate setup of hoses and began initial fire fighting until the Covert Fire department arrived, some 15 minutes later.
The cause of the fire has not been determined. An investigation will be initiated. There were no injuries and no one was in the trailer office at the time.
A safety inspection of all plant offices and trailers for potential fire hazards will be conducted on 06/18/99.
The licensee notified the NRC Resident Inspector.
A fire of undetermined origin was discovered by a janitor at 2240 on 06/17/99 in a temporary office trailer, north of the Palisades Training Building. The trailer complex is located one-half mile from the operating plant. There was no impact to the Training Building or the plant's operation, and the plant remained at full power.
The control room was notified after discovery of the blaze. The control room dispatched the plant's fire brigade and Covert Fire and Ambulance department to the scene. The plant fire brigade began immediate setup of hoses and began initial fire fighting until the Covert Fire department arrived, some 15 minutes later.
The cause of the fire has not been determined. An investigation will be initiated. There were no injuries and no one was in the trailer office at the time.
A safety inspection of all plant offices and trailers for potential fire hazards will be conducted on 06/18/99.
The licensee notified the NRC Resident Inspector.
Other Nuclear Material
Event Number: 35921
Rep Org: MIDWEST MEDICAL GROUP
Licensee: MIDWEST MEDICAL GROUP
Region: 3
City: ELKHART State: IN
County:
License #: 13-26679-01
Agreement: N
Docket:
NRC Notified By: BARBARA IANELLO
HQ OPS Officer: STEVE SANDIN
Licensee: MIDWEST MEDICAL GROUP
Region: 3
City: ELKHART State: IN
County:
License #: 13-26679-01
Agreement: N
Docket:
NRC Notified By: BARBARA IANELLO
HQ OPS Officer: STEVE SANDIN
Notification Date: 07/15/1999
Notification Time: 16:00 [ET]
Event Date: 06/17/1999
Event Time: 00:00 [CST]
Last Update Date: 07/15/1999
Notification Time: 16:00 [ET]
Event Date: 06/17/1999
Event Time: 00:00 [CST]
Last Update Date: 07/15/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
10 CFR Section:
Person (Organization):
RONALD GARDNER (R3)
DON COOL (NMSS)
RONALD GARDNER (R3)
DON COOL (NMSS)
THE LICENSEE RECEIVED A SHIPMENT WHOSE EXTERIOR NON-FIXED CONTAMINATION LEVELS EXCEEDED THE ALLOWABLE LIMITS.
ON 6/17/99 THE MIDWEST MEDICAL GROUP LOCATED AT 500 ARCADE BLVD IN ELKHART, INDIANA, RECEIVED A SHIPMENT FROM SPECTRUM PHARMACY CONTAINING TECHNETIUM 99. A SWIPE OF THE EXTERIOR READ 37,551 DPM WHICH EXCEEDS THE ALLOWABLE CONTAMINATION LIMITS OF 10CFR20.1906 FOR A GAMMA EMITTER. THE PACKAGE WAS ISOLATED AND ALLOWED TO DECAY. THE SHIPPER WAS NOTIFIED BY THE LICENSEE. THE LICENSEE IS MAKING THIS REPORT FOLLOWING AN ONSITE INSPECTION BY REGION III (BOB GATTONE).
ON 6/17/99 THE MIDWEST MEDICAL GROUP LOCATED AT 500 ARCADE BLVD IN ELKHART, INDIANA, RECEIVED A SHIPMENT FROM SPECTRUM PHARMACY CONTAINING TECHNETIUM 99. A SWIPE OF THE EXTERIOR READ 37,551 DPM WHICH EXCEEDS THE ALLOWABLE CONTAMINATION LIMITS OF 10CFR20.1906 FOR A GAMMA EMITTER. THE PACKAGE WAS ISOLATED AND ALLOWED TO DECAY. THE SHIPPER WAS NOTIFIED BY THE LICENSEE. THE LICENSEE IS MAKING THIS REPORT FOLLOWING AN ONSITE INSPECTION BY REGION III (BOB GATTONE).