Skip to main content

Event Notification Report for April 29, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/28/1999 - 04/29/1999

EVENT NUMBERS
356593565135653356543565535656

General Information or Other
Event Number: 35659
Rep Org: NRC REGION III
Licensee: STERIGENICS
Region: 3
City: GURNEE   State: IL
County:
License #: IL-01220-01
Agreement: Y
Docket:
NRC Notified By: JIM LYNCH
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/30/1999
Notification Time: 13:54 [ET]
Event Date: 04/29/1999
Event Time: 19:15 [CDT]
Last Update Date: 04/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN MADERA (R3)
SCOTT MOORE (NMSS)
Event Text
A SOURCE RACK FAILED TO RETURN TO THE POOL AT AN IRRADIATOR FACILITY

A source rack failed to return to the shielded position in the pool at Sterigenic's irradiator facility in Gurnee, IL. The licensee investigated the problem and determined that a bolt was getting hung up in the guide cable and mechanically binding. They were able to lower and unload the source rack and make repairs. The source rack has been reloaded and the facility is back in operation. No injuries or over exposures occurred as a result of this event.

This event was phoned in to the NRC Operations Center by NRC Region III.


Power Reactor
Event Number: 35651
Facility: SUMMER
Region: 2     State: SC
Unit: [1] [] []
RX Type: [1] W-3-LP
NRC Notified By: APRIL RICE
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 04/29/1999
Notification Time: 11:17 [ET]
Event Date: 04/29/1999
Event Time: 09:28 [EDT]
Last Update Date: 04/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
AL BELISLE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
- DEATH OF A CONTRACT EMPLOYEE -

At 0928 on 04/29/99, South Carolina Electric & Gas Company was notified that a Fluor Daniel contract employee had passed away. The individual had fallen unconscious earlier in the day while on a break and had been evacuated to a local hospital (Richland County Memorial Hospital). The individual was not contaminated and this event is not attributed to a work related injury. The exact cause of death is not known at this time. Local officials (e.g. the Fairfield County coroner) and the NRC Resident Inspector have been notified. The licensee does not plan to issue a press release at this time.


Power Reactor
Event Number: 35653
Facility: NORTH ANNA
Region: 2     State: VA
Unit: [1] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: RICHARD WESLEY
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/29/1999
Notification Time: 12:11 [ET]
Event Date: 04/29/1999
Event Time: 12:05 [EDT]
Last Update Date: 04/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - OTHER ASMT/COMM INOP
Person (Organization):
AL BELISLE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
MAINTENANCE ON TECHNICAL SUPPORT CENTER POWER SUPPLY

Planned maintenance is being performed on the TSC electrical supply which results in a loss of the electrical service to the TSC for more than one hour. The maintenance is expected to last four hours and started at 1205 on 4/29/99.

The licensee will notify the NRC resident inspector.


Power Reactor
Event Number: 35654
Facility: BRAIDWOOD
Region: 3     State: IL
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GREG BAKER
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/29/1999
Notification Time: 14:14 [ET]
Event Date: 04/29/1999
Event Time: 07:58 [CDT]
Last Update Date: 04/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
26.73 - FITNESS FOR DUTY
Person (Organization):
JOHN MADERA (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N N 0 Refueling 0 Refueling
Event Text
A CONTRACT SUPERVISOR WAS DETERMINED TO BE UNDER THE INFLUENCE OF ALCOHOL DURING A FOR-CAUSE TEST. THE EMPLOYEE'S ACCESS TO THE SITE HAS BEEN TERMINATED. CONTACT THE OPERATIONS CENTER FOR ADDITIONAL DETAILS. THE LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR.


Power Reactor
Event Number: 35655
Facility: DIABLO CANYON
Region: 4     State: CA
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: DAVID PATTY
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/29/1999
Notification Time: 16:21 [ET]
Event Date: 04/29/1999
Event Time: 12:45 [PDT]
Last Update Date: 04/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
DAVID GRAVES (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 50 Power Operation 50 Power Operation
Event Text
MISSED SURVEILLANCE ON POWER RANGE LOWER POWER TRIP

Technical Specification 4.3.1.2 Surveillance Requirement for Reactor Trip System Response Time for the Power Range Low Set Point Trip for was performed during initial startup testing. It has not been performed since 1975 on Unit 1 and 1984 on Unit 2. This function is required to be operable in Mode 2 and in Mode 1 below P-10 (10% power). Each unit has been in Modes 1 and 2 many times without a current response time test. The next time each unit goes below P-10, Technical Specification 4.0.3 Action will be applied (the surveillance will be performed).

The licensee notified the NRC resident inspector.

This discrepancy was discovered during an engineering department review of Standard Technical Specifications.


Other Nuclear Material
Event Number: 35656
Rep Org: TRIAD ENGINEERING
Licensee: TRIAD ENGINEERING
Region: 2
City: WINCHESTER   State: VA
County:
License #:
Agreement: N
Docket:
NRC Notified By: DENNIS CHAMBERS
HQ OPS Officer: DOUG WEAVER
Notification Date: 04/29/1999
Notification Time: 18:52 [ET]
Event Date: 04/29/1999
Event Time: 16:00 [EDT]
Last Update Date: 04/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
AL BELISLE (R2)
FREDERICK COMBS (NMSS)
Event Text
STOLEN TROXLER GAUGE

A TROXLER moisture density gauge was stolen from a work site in Fairfax, VA. The gauge was in the back of a pickup truck when the truck was stolen late in the afternoon of 4/29/99. A report has been filed with the police.
The gauge contains Cs-137 and Am-241. The gauge was a model 3411B, the first character of the serial number was not clearly legible on the paperwork, but ended with the numbers 929.