Event Notification Report for April 27, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/26/1999 - 04/27/1999

EVENT NUMBERS
3564335644356373563835639356403564135642

Fuel Cycle Facility
Event Number: 35643
Facility: PORTSMOUTH GASEOUS DIFFUSION PLANT
Region: 3     State: OH
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: RON CRABTREE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 21:48 [ET]
Event Date: 04/27/1999
Event Time: 13:12 [EDT]
Last Update Date: 04/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN MADERA (R3)
FREDERICK COMBS (NMSS)
Event Text
VALID ACTUATION OF A 'Q' SAFETY SYSTEM (24-HOUR REPORT)

The following text is a portion of a facsimile received from Portsmouth:

"At approximately 1312 hours [on] 04/27/99, operations personnel responded to a smokehead alarm (#SSWE) at the X-33O Tails Withdrawal facility. While no smoke was discovered during the investigation of the alarm, additional investigation revealed visible evidence of a minor UF6 leakage on the stem of valve WL-1. Due to the evidence of outgassing on valve WL-1, which is physically located in the vicinity of smokehead #SSWE, [Portsmouth] is reporting this discovery as a valid actuation of a 'Q' safety system."

"This is reportable to the NRC as a valid actuation of a 'Q' safety system in accordance with Safety Analysis Report, Section 6.9. (24-hour report)."

"There was no radioactive/radiological contamination exposure as a result of this event."

Portsmouth personnel notified the NRC resident inspector and the Department of Energy site representative.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35644
Facility: DIABLO CANYON
Region: 4     State: CA
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RODERTO ARROYO
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 22:14 [ET]
Event Date: 04/27/1999
Event Time: 18:45 [PDT]
Last Update Date: 05/21/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
DAVID GRAVES (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 50 Power Operation 50 Power Operation
Event Text
DISCOVERY OF A SAFEGUARDS SYSTEM DEGRADATION RELATED TO A VITAL AREA BARRIER

Security personnel discovered a safeguard system degradation related to the vital area barrier. Immediate compensatory actions were taken upon discovery. (Contact the NRC Operations Officer for additional details and for a licensee contact telephone number.)

The licensee notified the NRC Resident Inspector.

* * * UPDATE AT 1746 ON 05/26/99 BY JOHN HUBBLE TO JOLLIFFE * * *

The licensee is retracting this event since adequate compensatory measures were already in place when this degradation was discovered. (Contact the NRC Operations Officer for additional details.)

The licensee plans to notify the NRC Resident Inspector.

The NRC Operations Officer notified the R4DO Gary Sanborn.


Power Reactor
Event Number: 35637
Facility: CALVERT CLIFFS
Region: 1     State: MD
Unit: [1] [2] []
RX Type: [1] CE,[2] CE
NRC Notified By: DOUG BAUDER
HQ OPS Officer: BOB STRANSKY
Notification Date: 04/27/1999
Notification Time: 14:36 [ET]
Event Date: 04/27/1999
Event Time: 13:50 [EDT]
Last Update Date: 04/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(v) - EMERGENCY SIREN INOP
Person (Organization):
CLIFFORD ANDERSON (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N N 0 Refueling 0 Refueling
Event Text
24 OF 49 EMERGENCY SIRENS INOPERABLE

The licensee declared 24 of 49 emergency sirens inoperable after they failed silent pulse tests. The licensee is troubleshooting the problem; however, the sirens have not yet been returned to service. The NRC resident inspector has been informed of this notification.


Power Reactor
Event Number: 35638
Facility: GINNA
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: KEVIN McLAUGHLIN
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 16:04 [ET]
Event Date: 04/27/1999
Event Time: 12:48 [EDT]
Last Update Date: 04/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
CLIFFORD ANDERSON (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 A/R Y 90 Power Operation 0 Hot Standby
Event Text
AUTOMATIC REACTOR TRIP DUE TO A SPURIOUS OVER-TEMPERATURE DELTA TEMPERATURE (OT DELTA T) SIGNAL ON ONE CHANNEL WHILE ANOTHER CHANNEL WAS IN A TRIPPED CONDITION FOR TESTING

The following text is a portion of a facsimile received from the licensee:

"At about 1248 [EDT], the reactor tripped [from 90% power] due to a spurious OT Delta T [signal] on channel 3. Channel 2 was already in the tripped condition due to [reactor protection channel] testing per [procedure] CPI-Trip-Test-5.20. All [automatic] actions occurred as designed. All control rods [fully] inserted."

"[The] cause of the OT Delta T [signal] on channel 3 is under investigation."

The licensee stated that there were no emergency core cooling system actuations. Auxiliary feedwater automatically as expected due to steam generator level shrink, and main feedwater was subsequently secured. The licensee also stated that the condenser was not available as the heat sink due to the cooldown of the reactor coolant system. The unit recently exited a refueling outage, and there is not much decay heat. As a result, the main steam isolation valves were manually closed and the atmospheric steam dumps were used. (There have been no recent indications of steam generator tube leakage.)

The reactor is currently stable in Mode 3 (Hot Standby). The reactor coolant pumps, pressurizer heaters and sprays, and normal charging and letdown are currently being utilized for primary system transport, pressure, and inventory control. All containment parameters appear to be normal. Auxiliary feedwater is currently supplying water to the steam generators, and the atmospheric steam dumps are being used to relieve secondary steam. The emergency diesel generators are operable, and offsite power is also available.

The licensee notified the NRC resident inspector.


Fuel Cycle Facility
Event Number: 35639
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 3     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: K. A. BEASLEY
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 16:45 [ET]
Event Date: 04/27/1999
Event Time: 11:10 [CDT]
Last Update Date: 04/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2)(ii) - EQUIP DISABLED/FAILS
Person (Organization):
JOHN MADERA (R3)
FREDERICK COMBS (NMSS)
Event Text
FAILURE TO IMPLEMENT ACTIONS WITHIN THE ALLOWED TIME FRAME DUE TO FAILURE TO REALIZE THAT THE SAFETY FUNCTION OF THE PROCESS GAS LEAK DETECTION SYSTEM HAD BEEN RENDERED INOPERABLE (24-HOUR REPORT)

The following text is a portion of a facsimile received from Paducah:

"On 04/27/99 at 1110 CDT, the Plant Shift Superintendent (PSS) was notified that the C-333, Unit-5, Cell-1, Process Gas Leak Detection (PGLD) system had been rendered inoperable, and a failure to meet the required Limiting Condition for Operation (LCO) action had occurred. At approximately 0922 CDT, a PGLD alarm for detector head YE-45 was received on the control room panel for Unit 5, Cell 1, which was operating in Cascade Mode 2 (Above Atmospheric Pressure). This detector head alarms on the Unit-5 Cell-1 panel; however, it serves the #2 Purge and Evacuation Pump, which was in a non-applicable Mode. An operator responded to the local cell panel according to the alarm response procedure. At this time, while in contact with the area control room, the operators assumed that the head had failed because the head would not reset. They then determined that the equipment that this head serves was in a non-applicable mode. The PGLD system that head YE-45 is located on also serves Unit 5, Cell 1, which is in an applicable mode. Due to the alarm not resetting, this left the alarm in the area control room in an alarm condition, thus preventing subsequent notification or any future alarms. Since the operators did not realize that the safety function of the PGLD system had been rendered inoperable, the appropriate LCO actions were not implemented within the [1-hour] allowed time frame."

"It has been determined that this event is reportable under 10CFR76.120(c)(2) as an event in which equipment is [disabled] or fails to function as designed."

Paducah personnel notified the NRC resident inspector.


Other Nuclear Material
Event Number: 35640
Rep Org: U.S. ARMY (ACALA)
Licensee: U.S. ARMY (ACALA)
Region: 0
City: OVERSEAS   State:
County:
License #: 12-00722-06
Agreement: Y
Docket:
NRC Notified By: JEFF HAVENER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 16:53 [ET]
Event Date: 04/27/1999
Event Time: 16:45 [EDT]
Last Update Date: 04/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(i) - LOST/STOLEN LNM>1000X
Person (Organization):
JOHN MADERA (R3)
FREDERICK COMBS (NMSS)
CLIFFORD ANDERSON (R1)
Event Text
DISCOVERY OF THE POSSIBLE LOSS OF FOUR M43A1 CHEMICAL AGENT DETECTORS (EACH CONTAINING 250 µCi OF AMERICIUM-241) AND TWO CHEMICAL AGENT MONITORS (EACH CONTAINING UP TO 15 mCi OF NICKEL-63) OVERSEAS

The U.S. Army (located in Rock Island, Illinois) reported that four M43A1 chemical agent detectors and two CAMs (chemical agent monitors) may have been lost overseas. Each missing M43A1 contains 250 µCi of Americium-241, and each missing CAM contains up to up to 15 mCi of Nickel-63.

These items were issued to a battalion of the 10th Infantry Division. The battalion returned from Bosnia approximately 6 months ago and is currently located at Fort Drum in New York. Discovery of the missing items occurred during performance of an inventory (possibly a change-of-command inventory/date unknown). At approximately 1545 CDT on 04/27/99, a battalion representative informed the U.S. Army at Rock Island, Illinois, that the missing items may have been lost overseas.

(Call the NRC operations officer for a licensee contact telephone number.)


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35641
Facility: DRESDEN
Region: 3     State: IL
Unit: [] [2] [3]
RX Type: [1] GE-1,[2] GE-3,[3] GE-3
NRC Notified By: DAVID THRONE
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 17:53 [ET]
Event Date: 04/27/1999
Event Time: 15:55 [CDT]
Last Update Date: 04/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
JOHN MADERA (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 99 Power Operation 99 Power Operation
3 N Y 99 Power Operation 99 Power Operation
Event Text
DISCOVERY OF A SAFEGUARDS SYSTEM DEGRADATION RELATED TO THE PERIMETER AREA
(1-HOUR REPORT)

Security personnel discovered a safeguard system degradation related to the perimeter area. Immediate compensatory actions were taken upon discovery. (Contact the NRC operations officer for additional details.)

The licensee plans to notify the NRC resident inspector.

* * * UPDATE AT 2007 ON 4/29/99 BY BORING TAKEN BY WEAVER * * *

The licensee is retracting this event based on further review and concluding that the event did not constitute a reportable condition. This conclusion is based on the fact that compensatory measures were re-established within specified time standards. The licensee will inform the NRC resident inspector. The HOO notified the R3DO (Madera).


Fuel Cycle Facility
Event Number: 35642
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 3     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: ERIC WALKER
HQ OPS Officer: LEIGH TROCINE
Notification Date: 04/27/1999
Notification Time: 18:31 [ET]
Event Date: 04/27/1999
Event Time: 09:25 [CDT]
Last Update Date: 04/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
JOHN MADERA (R3)
FREDERICK COMBS (NMSS)
Event Text
SAFETY SYSTEM ACTUATION DUE TO A VALID SIGNAL (24-HOUR REPORT)

The following text is a portion of a facsimile received from Paducah:

"At 0925 CDT on 04/27/99, [the] C-337a Autoclave Position 2 West received a High Autoclave Steam Pressure Alarm while in TSR mode 5. The Autoclave Steam Pressure Control System is required to be operable while in mode 5 per LCO 2.2.3.3. Systems actuated as designed. TroubleshootIng of [the] system revealed failure of the steam controller. When the controller failed, an increase in autoclave steam pressure was observed by the Autoclave Steam Pressure Control System, and steam was isolated from the autoclave. [The] cause of the steam controller failure is being investigated by system engineer."

"The safety system activation is reportable to the NRC as required by Safety Analysis Report, Section 6.9, Table 1, Criteria J.2, safety system actuation due to a valid signal as a 24-hour event notification."

Paducah personnel notified the NRC resident inspector.