Event Notification Report for April 11, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
04/10/1999 - 04/11/1999

EVENT NUMBERS
35589355733557435575

Fuel Cycle Facility
Event Number: 35589
Facility: PADUCAH GASEOUS DIFFUSION PLANT
Region: 3     State: KY
Unit: [] [] []
RX Type: URANIUM ENRICHMENT FACILITY
Comments: 2 DEMOCRACY CENTER
6903 ROCKLEDGE DRIVE
BETHESDA, MD 20817 (301)564-3200
NRC Notified By: HALICKS
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 04/13/1999
Notification Time: 14:40 [ET]
Event Date: 04/11/1999
Event Time: 21:45 [CDT]
Last Update Date: 04/13/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
76.120(c)(2)(ii) - EQUIP DISABLED/FAILS
Person (Organization):
JOHN JACOBSON (R3)
FRED COMBS (NMSS)
Event Text
THE PLANT SHIFT SUPERINTENDENT(PSS) WAS NOTIFIED THAT THERE HAD BEEN A FAILURE OF THE UF6 RELEASE DETECTION SYSTEM IN THE C-333 PROCESS BUILDING UNIT 5 CELL 4. THE FAILURE OCCURRED DURING THE TWICE-PER-SHIFT TSR SURVEILLANCE WHICH REQUIRES "TEST FIRING" OF THE DETECTOR HEADS. THE PSS IMMEDIATELY DECLARED THE SAFETY SYSTEM INOPERABLE AND DIRECTED THE IMPLEMENTATION OF TSR-REQUIRED ACTIONS WHICH INCLUDE PLACING A "SMOKE WATCH" IN THE AFFECTED AREA. IN ADDITION, THE OPERATING PRESSURE OF THE AFFECTED EQUIPMENT WAS REDUCED TO BELOW ATMOSPHERIC PRESSURE WHICH PLACED THE EQUIPMENT IN A MODE IN WHICH THE SAFETY SYSTEM WAS NOT REQUIRED TO BE AVAILABLE AND OPERABLE. THE PSS WAS SUBSEQUENTLY NOTIFIED (AT 0130 ON 4/12/99) THAT THE EQUIPMENT HAD ACTUALLY FAILED DURING THE TEST AT APPROXIMATELY 2145. COMPENSATORY ACTIONS WERE NOT IMPLEMENTED IN A TIMELY MANNER IN ACCORDANCE WITH THE APPLICABLE TSR. THE TSR-REQUIRED ACTIONS WERE REQUIRED TO BE IMPLEMENTED WITHIN 1 HOUR AND WERE IMPLEMENTED APPROXIMATELY 80 MINUTES LATE.

THIS EVENT IS BEING SUBMITTED LATE DUE TO A MISINTERPRETATION OF THE EVENT REPORTING CRITERIA.

THE RESIDENT INSPECTOR HAS BEEN NOTIFIED.


Power Reactor
Event Number: 35573
Facility: WATTS BAR
Region: 2     State: TN
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: RICK O'REAR
HQ OPS Officer: FANGIE JONES
Notification Date: 04/11/1999
Notification Time: 02:46 [ET]
Event Date: 04/11/1999
Event Time: 00:42 [EDT]
Last Update Date: 04/11/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - RPS ACTUATION
Person (Organization):
WALTER RODGERS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 M/R N 0 Hot Standby 0 Hot Standby
Event Text
MANUAL REACTOR TRIP DUE TO CONTROL ROD DRIVE MALFUNCTION

"Watts Bar Unit 1 experienced a Manual Reactor Trip during Control Rod Testing while in Mode 3 (with Reactor shutdown for Refueling Outage). At 0042 on 04/11/1999, the Main Control Room Crew manually opened the
Reactor Trip Breakers when the Control Rod Drive system continued to withdraw Shutdown Bank A following a Manual withdrawal to 10 steps. The rods should have stopped at 10 steps withdrawn. This was the first in a
sequence of rod withdrawals per Surveillance instruction 1-S I-85-2.

"All other rods were fully inserted at the time of testing Shutdown Bank A with RCS Boron concentration at 2184 PPM. When Shutdown Bank A continued to withdraw, the SRO directed the Reactor Trip breakers to be
opened and verified all rods fully inserted. All systems responded as expected. The Unit remains stable in Mode 3.

"In addition, this generated a Main Feedwater Isolation Signal. At the time of the event, all feedwater lines were isolated for outage work.

"At present, an investigation is in progress to determine cause of event and Control Rod Testing has been suspended pending outcome of that investigation."

The licensee notified the NRC Resident Inspector.


Power Reactor
Event Number: 35574
Facility: SALEM
Region: 1     State: NJ
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: PETE JONES
HQ OPS Officer: BOB STRANSKY
Notification Date: 04/11/1999
Notification Time: 17:52 [ET]
Event Date: 04/11/1999
Event Time: 15:54 [EDT]
Last Update Date: 04/11/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
JOHN KINNEMAN (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Refueling 0 Refueling
Event Text
CONTAINMENT VENTILATION ISOLATION

During the process of lifting the reactor vessel head, the containment noble gas monitor (2R12A) alarmed, causing a containment ventilation isolation. The containment purge isolation valves closed as a result of the isolation. Nonessential personnel were immediately evacuated from containment, and all remaining personnel (except the crane operator) were evacuated after the reactor vessel head was placed onto its stand. The crane operator is required to be on station in accordance with station procedures. The licensee is analyzing samples taken from the containment atmosphere. The NRC resident inspector will be informed of this notification by the licensee.


Power Reactor
Event Number: 35575
Facility: CATAWBA
Region: 2     State: SC
Unit: [1] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: GARY HAMILTON
HQ OPS Officer: BOB STRANSKY
Notification Date: 04/11/1999
Notification Time: 21:13 [ET]
Event Date: 04/11/1999
Event Time: 20:21 [EDT]
Last Update Date: 04/11/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(i)(A) - PLANT S/D REQD BY TS 50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
WALTER RODGERS (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
2 N Y 100 Power Operation 100 Power Operation
Event Text
CONTROL ROOM CHILLERS DECLARED INOPERABLE

Both control room ventilation chillers were declared inoperable due to high temperature in the Standby Nuclear Service Water pond. The system had been operating in an "operable but degraded" condition due to fouling of tubes in the chiller condensers. The engineering analysis in support of continued system operation specified a maximum Standby Nuclear Service Water pond temperature of 70°F (the normal temperature limit for the pond is 91.5°F). The licensee is currently attempting to cool the pond, but stated that preparations are also being made to commence a dual unit shutdown. The NRC resident inspector will be informed of this notification by the licensee.

* * * UPDATE 2148 4/11/1999 FROM HAMILTON TAKEN BY STRANSKY * * *

The licensee commenced shutdowns of both units at 2120. At 2133, the "B" control room chiller was restored to operable, and the shutdowns were terminated. Reactor power had been decreased to 98%, and is being returned to rated. The NRC resident inspector will be informed of this notification by the licensee.