Event Number: 35540
Rep Org: H & G INSPECTION
Licensee: H & G INSPECTION
Region: 4
City: HOUSTON   State: TX
County:
License #: 42-26838-01
Agreement: Y
Docket:
NRC Notified By: CRAIG KONIECZNY
HQ OPS Officer: STEVE SANDIN
Notification Date: 04/02/1999
Notification Time: 11:08 [ET]
Event Date: 04/02/1999
Event Time: 04:40 [CST]
Last Update Date: 04/02/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
30.50(b)(2) - SAFETY EQUIPMENT FAILURE 30.50(b)(2)(ii) - EQUIP DISABLED/FAILS 30.50(b)(2)(iii) - REDUNDANT EQUIP INOP
Person (Organization):
LINDA HOWELL (R4)
DON COOL (NMSS)
Event Text
SUSPECTED FAILURE OF AUTO LOCKING MECHANISM PREVENTING RETRACTION OF IR-192 SOURCE IN A RADIOGRAPHY CAMERA.

DURING A CAMERA SHOT AT A POWER PLANT LOCATED A COUPLE MILES FROM THE EVANSTON, WYOMING, OFFICE, THE IRIDIUM-192 SOURCE WOULD NOT RETRACT INTO THE SHIELDED VOLUME. THE LICENSEE (H & G INSPECTION COMPANY) AREA MANAGER RESPONDED TO THE SCENE AND TRANSFERRED THE SOURCE TO AN EMPTY CAMERA. BOTH THE RADIOGRAPHER AND THE AREA MANAGER ARE ESTIMATED TO HAVE RECEIVED LESS THAN 200 MREM/EACH. (THE DOSIMETRY REMAINED ON-SCALE.)

SPECIFIC INFORMATION IS AS FOLLOWS:

1. THE CAMERA WAS MANUFACTURED BY INDUSTRIAL NUCLEAR LOCATED IN CALIFORNIA, MODEL
IR100.
2. THE SOURCE WAS MANUFACTURED BY SOURCE PRODUCTION COMPANY LOCATED IN
LOUISIANA, S/N 4258.

THE LICENSEE REQUIRED APPROXIMATELY 5 HOURS TO RECOVER THE FRESHLY INSTALLED SOURCE (ABOUT 100 CURIES) DURING WHICH TIME THE POWER PLANT WAS SHUTDOWN. THE LICENSEE IS CONDUCTING AN INVESTIGATION AND PLANS ON RETURNING THE CAMERA TO THE MANUFACTURER FOR EVALUATION. AT THIS TIME, THE LICENSEE SUSPECTS A FAILURE IN THE AUTO LOCKING MECHANISM.

AN NRC REGION 4 INSPECTOR (CRUZ) WAS PRESENT IN THE HOUSTON OFFICE AND WAS AWARE OF THE INCIDENT. THE LICENSEE PLANS TO SUBMIT A WRITTEN REPORT.

CALL THE HEADQUARTERS OPERATIONS OFFICER FOR CONTACT INFORMATION.


Power Reactor
Event Number: 35541
Facility: OYSTER CREEK
Region: 1     State: NJ
Unit: [1] [] []
RX Type: [1] GE-2
NRC Notified By: STEVE FULLER
HQ OPS Officer: FANGIE JONES
Notification Date: 04/02/1999
Notification Time: 12:11 [ET]
Event Date: 04/02/1999
Event Time: 12:00 [EST]
Last Update Date: 04/02/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
KATHLEEN MODES (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
THREE CABLE TRAYS FOUND IN REACTOR BUILDING DO NOT MEET SEPARATION CRITERIA.

The licensee discovered three cable trays in the reactor building that do not meet the design criteria for separation of trains. The discovery was during a walkdown of cable trays in the plant following review of similar events in the industry.

Corrective action will be to install fire barrier material between the division 1 and 2 cable trays. The design for the barriers has been started, and the actual work is expected to be complete within 2 weeks. It has been determined that interim measures, such as a fire watch, are not necessary because the cable trays carry only low amperage instrument and control cables and because they are fused.

The licensee intends to notify the NRC Resident Inspector.