Event Notification Report for March 29, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/28/1999 - 03/29/1999

EVENT NUMBERS
3552535529355303552235523

Power Reactor
Event Number: 35525
Facility: BEAVER VALLEY
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: TOM COTTER
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/29/1999
Notification Time: 20:22 [ET]
Event Date: 03/29/1999
Event Time: 18:01 [EST]
Last Update Date: 03/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
KATHLEEN MODES (R1)
STUART RICHARDS (NRR)
FRANK CONGEL (IRO)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
PARTIAL LOSS OF POWER DUE TO 4.10KV BUS UNIT STATION SERVICE TRANSFORMER SUPPLY OVERCURRENT TRIP. EMERGENCY DIESEL GENERATOR 2-1 SUPPLYING POWER TO VITAL BUS "AE".

At 1801 hours, "4160V Bus Unit Station Service Transformer Supply Overcurrent Trip" alarm was received. This alarm indicates that the supply breaker, 42C, to the normal 4kV bus "2A" opened and deenergized the bus. The "2A" bus supplies train "A" emergency 4kV bus "AE" so it also deenergized. The emergency diesel generator 2-1 started and reenergized the "AE" emergency bus. The "B" train of electrical power and safeguards equipment remained fully operable, the emergency diesel generator is fully operable if needed. Prior to the overcurrent trip, the plant was in mode 5 (cold shutdown) with Reactor Coolant System temperature at 97°F and 280 psig. Their was no interruption to core cooling during the event. Core cooling was being provided by the "B" train of the residual heat removal system and was unaffected. Both trains of residual heat removal remain operable. The site maintenance department is evaluating the cause for the relay protection actuation. The 2-1 emergency diesel generator will continue to supply the emergency bus until this investigation is completed and normal power is restored. The vital buses cannot be cross connected and emergency diesel generator 2-1 has plenty of fuel to keep it operating. Spent fuel pool cooling was not lost.

Offsite power is stable, and the other emergency bus "2DF" can supply enough electrical power to safe plant operation while shutdown if electrical power is lost from emergency bus "2AE".

The NRC Resident Inspector was notified of this event by the licensee.


***Update on 03/30/99 at 1542 ET from R. Scheib taken by MacKinnon***

Emergency Diesel Generator 2-1 secured after offsite power was restored to Bus 2A at 1148 ET.

The licensee checked out relays and breakers before restoring offsite power. The licensee said that DC Charger Bus 5, which supplies "2A" 4kV bus protection relays with power had been oscillating. The licensee found Technical Manual information that indicated that the overcurrent relays are susceptible to ripples. 5% ripples can cause an overcurrent trip. The licensee had regulating problems with the Bus 5 Charger, and they think that the regulating problems caused the overcurrent trip. R1DO (Kathleen Modes) notified.

The NRC Resident Inspector was notified of this event update.


Power Reactor
Event Number: 35529
Facility: SOUTH TEXAS
Region: 4     State: TX
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: WAYNE HARRISON
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/30/1999
Notification Time: 14:21 [ET]
Event Date: 03/29/1999
Event Time: 21:29 [CST]
Last Update Date: 03/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
LINDA HOWELL (R4)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
CONTROL ROOM HVAC PLACED IN RECIRCULATION MODE OF OPERATION OF INSTEAD OF BEING PLACED IN FILTERED RECIRCULATION AND MAKE-UP FILTRATION MODE.

This event was reported per paragraph 2.G of South Texas Project Operating License.

On 03/29/99 at 2129 CST, Unit 1 was in mode 6 (refueling) and the "C" Train battery was removed from service. With the "C" Train battery inoperable, the Control Room HVAC was required to be put in filtered Recirculation and Make-up Filtration Mode within 48 hours per Technical Specification (TS) 3.3.2.10.C, Action 27. Instead, on 03/29/99 at 2129, the Control Room HVAC in the Make-up Filtration Mode resulted in a non-compliance with Technical Specification actions, which is a condition prohibited by TS per 50.73 (a)(2)(i)(B); and a 24 hour notification is required by 2G of the Operating License. The condition was identified and corrected at 0635 on 03/30/99.

The NRC Resident Inspector was notified of this event by the licensee.


Other Nuclear Material
Event Number: 35530
Rep Org: TENNESSEE DIV. OF RAD. HEALTH
Licensee: METHODIST CENTRAL HOSPITAL,
Region: 2
City: MEMPHIS   State: TN
County:
License #: TN-99-047
Agreement: Y
Docket:
NRC Notified By: DEBRA SHULTS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/30/1999
Notification Time: 16:35 [ET]
Event Date: 03/29/1999
Event Time: 00:00 [EST]
Last Update Date: 03/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
CHARLES OGLE (R2)
SCOTT MOORE (NMSS)
Event Text
A MAN SCHEDULED FOR A THERAPY DOSE TO HIS COLON WAS GIVEN A BRAIN TREATMENT INSTEAD.

The text following information is a portion of a facsimile received from the Tennessee Department of Environmental and Conversation Division of Radiological Health:

"On 03/30/99, the Radiation Safety Officer at Methodist Central Hospital, Memphis, reported a therapeutic misadministration to the Memphis Field Office Manager. The event occurred on 03/29/99. A man scheduled for a therapy dose to his colon was given a brain treatment instead. The dose to the brain was 200 rad. The man answered to the wrong name when called for treatment. A written report will be submitted to the State of Tennessee Department of Environmental and Conservation Division of Radiological Health within 15 days."

The machine used was a linear accelerator.


Power Reactor
Event Number: 35522
Facility: BRUNSWICK
Region: 2     State: NC
Unit: [] [2] []
RX Type: [1] GE-4,[2] GE-4
NRC Notified By: MARK SCHALL
HQ OPS Officer: BOB STRANSKY
Notification Date: 03/29/1999
Notification Time: 11:35 [ET]
Event Date: 03/29/1999
Event Time: 08:37 [EST]
Last Update Date: 03/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
MARK LESSER (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 A/R Y 97 Power Operation 0 Hot Shutdown
Event Text
AUTOMATIC TURBINE TRIP/REACTOR SCRAM DUE TO SPURIOUS HIGH VIBRATION SIGNAL

The unit received an automatic turbine trip/reactor scram due to a suspected spurious turbine high vibration signal. Following the scram, all control rods inserted, and all systems functioned as expected. Two safety/relief valves lifted but immediately reseated. Primary Containment Isolation System (PCIS) Group 2 (drywell equipment and floor drains, TIP, radwaste, and process sampling), 6 (containment atmosphere and post-accident sampling), and 8 (RHR shutdown cooling) isolations occurred due to reactor vessel water level shrinkage following the scram. Reactor vessel water level recovered shortly after the scram.

The licensee is currently investigating the cause of the turbine vibration signal. The NRC resident inspector has been informed of this event by the licensee.


Other Nuclear Material
Event Number: 35523
Rep Org: FLORIDA BUREAU OF RADIATION CONTROL
Licensee: H.W. LOCHNER
Region: 2
City: CLEARWATER   State: FL
County:
License #: 2333-1
Agreement: Y
Docket:
NRC Notified By: CHARLES ADAMS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/29/1999
Notification Time: 12:45 [ET]
Event Date: 03/29/1999
Event Time: 00:00 [EST]
Last Update Date: 03/29/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
MARK LESSER (R2)
FRED COMBS (NMSS)
Event Text
- AGREEMENT STATE REPORT - TROXLER MOISTURE DENSITY GAUGE RUN OVER -

While taking a measurement, a Troxler #3440 gauge (serial number 029358) was run over by a dump truck. The handle was broken off, and the source could not be retracted into the case. The source was extended approximately 12 inches. Investigators responded and put a pig over the source and transported the gauge to the state environmental lab. The gauge was placed in the Radioactive Activity Material storage facility until the owner can get a special shipping case from Troxler: to return the gauge for repair. Any further actions are referred to Materials Licensing. The licensee is the H. W. Lochner facility which is located in Clearwater, Florida.

Troxler Model #3440 contains 8 mCi of Cesium-137 and 40 mCi of Americium-241/Beryllium.

Call the NRC Operations Officer for contact numbers.