Power Reactor
Event Number: 35492
Facility: FITZPATRICK
Region: 1     State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: ALLEN
HQ OPS Officer: CHAUNCEY GOULD
Notification Date: 03/20/1999
Notification Time: 04:08 [ET]
Event Date: 03/20/1999
Event Time: 02:50 [EST]
Last Update Date: 04/19/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
JACK MCFADDEN (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
THE "A" HPCI WAS DECLARED INOPERABLE, RESULTING IN A 7 DAY LCO ACTION STATEMENT.

THE "A" HPCI ISOLATION LOGIC WAS DE-ENERGIZED, MAKING HPCI INOPERABLE, DUE TO A 120VDC BATTERY GROUND. THIS CONDITION ALSO ACTUATED VALVES "23MOV-15" (INBOARD STEAM ISOLATION VALVE) AND "23MOV-58" (INBOARD TORUS SUCTION VALVE). BOTH PENETRATIONS HAVE BEEN ISOLATED AND DE-ENERGIZED WITHIN 1 HOUR AS REQUIRED BY TECH SPECS. THE CAUSE OF THE GROUND IS UNKNOWN AND BEING INVESTIGATED.

THE RESIDENT INSPECTOR WILL BE NOTIFIED.


***Retraction on 04/19/99 at 1037 ET by Bob Steigerwald taken by MacKinnon****

This event is being retracted because of the following information because HPCI was capable of performing its intended safety function with the DC ground present.

Due to de-energization a portion of the HPCI system Containment Isolation Logic in order to isolate a ground on the 120 VDC bus HPCI was declared inoperable. Subsequent review of the DC ground determined that the ground was located on a surge suppressor for a signal to the plant computer (EPIC), and had no effect on HPCI system operability. The HPCI system isolation logic was taken out of service for the troubleshooting effort and the appropriate Limiting Condition for Operation was taken. Therefore, since HPCI was capable of performing its intended safety function with the DC ground present, this event is not reportable and the notification is being retracted. R1DO (Shanbaky) notified.

The NRC Resident Inspector was not of this retraction by the licensee.


Power Reactor
Event Number: 35493
Facility: PERRY
Region: 3     State: OH
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: ROBERT SOCHIA
HQ OPS Officer: DOUG WEAVER
Notification Date: 03/20/1999
Notification Time: 15:11 [ET]
Event Date: 03/20/1999
Event Time: 14:01 [EST]
Last Update Date: 03/20/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
GEOFFREY WRIGHT (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 90 Power Operation 90 Power Operation
Event Text
OFFSITE NOTIFICATION - SODIUM HYPOCHLORITE LEAK

A sodium hypochlorite leak was discovered emanating from the SW/ESW sodium hypochlorite tank into its surrounding dike. The leak of about 1500 gallons is completely contained within the dike. The licensee notified the U.S. EPA, the Ohio EPA, the U.S. Coast Guard and Lake County.

The NRC resident inspector was informed.


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35494
Facility: PILGRIM
Region: 1     State: MA
Unit: [1] [] []
RX Type: [1] GE-3
NRC Notified By: ERIC OLSON
HQ OPS Officer: DOUG WEAVER
Notification Date: 03/20/1999
Notification Time: 20:20 [ET]
Event Date: 03/20/1999
Event Time: 18:57 [EST]
Last Update Date: 04/21/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(iii)(D) - ACCIDENT MITIGATION
Person (Organization):
JACK MCFADDEN (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N Y 100 Power Operation 100 Power Operation
Event Text
RCIC INOPERABLE

The licensee declared Reactor Core Isolation Cooling (RCIC) inoperable because of a problem found during a surveillance. Relay 13A-k30 contacts 1 - 7 were found to have a high resistance. These contacts close to provide the 'A' channel input to the RCIC high level shutdown. A high resistance across these contacts may prevent the actuating relay (13A-k38) from energizing, and thereby prevent a shutdown of RCIC on a high reactor vessel water level. The RCIC high water level shutdown requires both channels 'A' and 'B' signals be present to occur.

The licensee entered a 14 day LCO because of this condition. Repair efforts are in progress. RCIC remains available for use in the event of an emergency.

The licensee will inform the NRC resident inspector.

* * * UPDATE at 1903 on 04/21/99 by MIKE ENGLAND to JOLLIFFE * * *

After further evaluation of this event, the licensee determined that the as-found condition of the RCIC System did not affect its operability since the last surveillance test. NUREG-1022, Rev 1, Section 3.2.2, Item 3, discusses this instance. Therefore, the RCIC System was not inoperable due to the above problem. Thus, the licensee desires to retract this report.

The licensee notified the NRC Resident Inspector. The NRC Operations Officer notified the R1DO MOHAMED SHANBAKY.