Skip to main content

Event Notification Report for March 15, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/14/1999 - 03/15/1999

EVENT NUMBERS
3547135472354733547435475

!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35471
Facility: CLINTON
Region: 3     State: IL
Unit: [1] [] []
RX Type: [1] GE-6
NRC Notified By: TIM HOLLAND
HQ OPS Officer: LEIGH TROCINE
Notification Date: 03/15/1999
Notification Time: 03:57 [ET]
Event Date: 03/15/1999
Event Time: 01:05 [CST]
Last Update Date: 03/17/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
RONALD GARDNER (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
UNANTICIPATED REACTOR CORE ISOLATION COOLING (RCIC) SUCTION VALVE ISOLATION DURING PERFORMANCE OF A REVISED TEST PROCEDURE

The following text is a portion of a facsimile received from the licensee:

"During the performance of CPS No. 9054.04 (RCIC Automatic Suction Shift Test), the RCIC suction valve from the suppression pool (1E51-F031) automatically isolated on a valid low steam line pressure signal. This isolation was not intended to occur during the performance of this procedure."

"The isolation occurred following the removal of a simulated RCIC steam line pressure signal of > 60 psig. When the current steam line pressure of 0 psig was picked up by the logic, the 1E51-F031 isolated as designed." Upon receipt of the valid low steam line pressure signal, all systems functioned as required. There was nothing unusual or not understood.

The licensee stated that the test procedure was newly revised and that some of the steps had been swapped. The steps should have requested opening of the other suction source, closure of this suction source, and then removal of the simulator.

The licensee notified the NRC resident inspector.

* * * RETRACTION 1511 3/17/1999 FROM SCHOFFAL TAKEN BY STRANSKY * * *

"The Low RCIC steam supply line pressure indicates that the pressure of the steam may be too low to continue operation of the RCIC turbine. The isolation function for this valve is for equipment protection and is not assumed in any transient or accident analysis in the UFSAR. However, the instrumentation providing the trip isolation signal also provides a diverse signal to indicate a possible system break.

"A review of this event has concluded that this issue is not reportable under the provisions of 10CFR50.72 as an actuation of an engineered safety feature. The basis for this conclusion is the isolation of valve 1E51-F031 is an actuation of a single component in a complex system (including the RCIC, Containment and Reactor Vessel Isolation, and Leak Detection Systems), and the actuation of this valve, by itself, would not mitigate the consequences of the possible system leak that could cause the low RCIC steam line pressure condition. This determination is consistent with the guidance provided in NUREG 1022, Section 3.32."

The NRC Resident Inspector has been informed of this retraction. The NRC Operations Officer notified the R3DO (Geoffrey Wright).


Power Reactor
Event Number: 35472
Facility: MILLSTONE
Region: 1     State: CT
Unit: [1] [] []
RX Type: [1] GE-3,[2] CE,[3] W-4-LP
NRC Notified By: DAVID DVORAK
HQ OPS Officer: BOB STRANSKY
Notification Date: 03/15/1999
Notification Time: 13:46 [ET]
Event Date: 03/15/1999
Event Time: 13:12 [EST]
Last Update Date: 03/15/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
JACK MCFADDEN (R1)
FEMA, DOE, DOA, HHS (FAX)
EPA, DOT (VIA NRC) (FAX)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Refueling 0 Refueling
Event Text
OFFSITE NOTIFICATION DUE TO OIL SPILL ONSITE

The licensee notified the Connecticut Department of Environmental Protection regarding a small release of oil into the Long Island Sound. A vehicle fire outside of the protected area (near the training facility) resulted in the spillage of approximately 30 gallons of a gasoline/oil mixture onto the ground. Attempts were made to contain the spill, but less than one gallon of the gasoline/oil mixture entered the storm drains and was released to the Long Island Sound. The licensee is currently working to clean up the spill. The NRC resident inspector has been informed of this event by the licensee.


General Information or Other
Event Number: 35473
Rep Org: FOXBORO COMPANY
Licensee: FOXBORO COMPANY
Region: 1
City: FOXBORO   State: MA
County:
License #:
Agreement: Y
Docket:
NRC Notified By: GEORGE JOHNSON
HQ OPS Officer: BOB STRANSKY
Notification Date: 03/15/1999
Notification Time: 16:10 [ET]
Event Date: 03/15/1999
Event Time: 00:00 [EST]
Last Update Date: 03/15/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
21.21 - UNSPECIFIED PARAGRAPH
Person (Organization):
VERN HODGE (via fax) (NRR)
Event Text
10 CFR PART 21 REPORT REGARDING INSPECTION DOCUMENTATION FOR SPARE PARTS

The following facsimile was submitted to the NRC Operations Center:

"In accordance with 10 CFR [Part] 21, this letter is to inform you that Foxboro Co. can not provide detail documentation of the inspection criteria to support the inspection process for spare parts that may have been released to customers in support of Foxboro Nuclear Qualified products. The time period affected is from March 31, 1998, to March 12, 1999."

"There is no evidence of any failures or defects in these parts. Foxboro is taking immediate corrective action to rectify the situation and will notify all utilities affected. Foxboro Co. will be notifying those nuclear utilities that have purchased commercial spare parts since April 1998. A review for corrective action is still under investigation."


!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Hospital
Event Number: 35474
Rep Org: WASHINGTON UNIV MEDICAL CTR
Licensee: WASHINGTON UNIV MEDICAL CTR
Region: 3
City: ST. LOUIS   State: MO
County:
License #: 24-00167-11
Agreement: N
Docket:
NRC Notified By: GILBERT NUSBAUM
HQ OPS Officer: BOB STRANSKY
Notification Date: 03/15/1999
Notification Time: 16:30 [ET]
Event Date: 03/15/1999
Event Time: 10:30 [CST]
Last Update Date: 03/30/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
35.33 - MED MISADMINISTRATION
Person (Organization):
GEOFFREY WRIGHT (R3)
JOE HOLONICH (NMSS)
Event Text
MEDICAL MISADMINISTRATION

A female patient was prescribed a dose of 3,000 cGy (rads) for gynecological treatment to be delivered in six fractions via a high dose rate (HDR) afterloader device. The dose was to be administered over a 30-mm linear distance, beginning at a distance of 960 mm from the HDR device head. The first five fractions were delivered as prescribed. The sixth fraction was delivered using the same spacing and dwell times as the other fractions; however, the treatment was started at a distance of 988 mm from the HDR device head. Thus, dose was administered to unintended tissue adjacent to the prescribed treatment site.

The referring physician has been notified, and the hospital plans to contact the patient. The licensee has contacted the NRC Region III office regarding this event.

* * * RETRACTION 1002 3/30/1999 FROM JOHN EICHLING TAKEN BY STRANSKY * * *

The licensee is retracting this notification. After consultation with NRC Region III (John Jones), the licensee has determined that this event did not constitute a medical misadministration. HOO notified R3DO (Ring).


Power Reactor
Event Number: 35475
Facility: ROBINSON
Region: 2     State: SC
Unit: [2] [] []
RX Type: [2] W-3-LP
NRC Notified By: DAVID COOK
HQ OPS Officer: LEIGH TROCINE
Notification Date: 03/16/1999
Notification Time: 01:20 [ET]
Event Date: 03/15/1999
Event Time: 22:12 [EST]
Last Update Date: 03/16/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
Person (Organization):
EDWARD MCALPINE (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
Event Text
COURTESY NOTIFICATION REGARDING A FATALITY WITHIN THE OWNER CONTROLLED AREA OUTSIDE THE 1,400-FOOT BARRIER

The following text is a portion of a facsimile received from the licensee:

"At approximately 2212 on 03/15/99, Robinson Security [personnel] notified the Control Room of an automobile with a fatality on the West Entrance Road access to the plant outside the site boundary. The cause of the fatality is unknown, and this occurrence is being investigated by local law enforcement agencies and the State Law Enforcement Division. Due to the fatality occurring off-site, but on CP&L property adjacent to the site boundary, and [due to] the interaction of several off-site agencies responding to the scene, the NRC Operations Center is being notified as a courtesy. This call is for informational purposes only and does not fall within the reporting criteria of 10 CFR 50.72."

The licensee notified the NRC resident inspector. The licensee does not plan to issue a press release.