Event Notification Report for March 05, 1999

U.S. Nuclear Regulatory Commission
Operations Center

EVENT REPORTS FOR
03/04/1999 - 03/05/1999

EVENT NUMBERS
3544635441354423544335444

Power Reactor
Event Number: 35446
Facility: BEAVER VALLEY
Region: 1     State: PA
Unit: [] [2] []
RX Type: [1] W-3-LP,[2] W-3-LP
NRC Notified By: GEORGE E. STOROLIS
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/05/1999
Notification Time: 20:02 [ET]
Event Date: 03/05/1999
Event Time: 18:30 [EST]
Last Update Date: 03/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
MICHAEL MODES (R1)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N N 0 Cold Shutdown 0 Cold Shutdown
Event Text
Discrepancies in the post-fire plant operating procedures identified.

A review with engineering fire protection self-assessment has identified discrepancies in the post-fire plant operating procedures. Various steps require manual actions to be performed in the fire area of concern. Smoke and heat from the postulated fire could prevent the actions from being accomplished as per the procedure instructions. Specifically in fire area PA-4 (Auxiliary Building, Elevation 755 feet), spurious operation of 2CHS*LCV115C or 2CHS*LCV115E, Volume Control Tank (VCT) outlet to charging pump suction valves, requires that the valve's breaker be opened to allow local closing of the associated valve. Even though the valves are located outside fire area PA-4, the operator has to travel through fire area PA-4 to get to the breakers. This action may not be able to be accomplished due to the fire event. If the VCT outlet is not isolated, there could be intrusion of gases from the VCT which could cause a loss of charging capability. The procedure provides inadequate actions to recover from this scenario. This could result in the plant not being able to achieve a safe shutdown as required by the fire protection analysis.

A condition report has been written to document this issue along with other potential procedure discrepancies. Currently Unit 2 is in Mode 5 (Cold Shutdown) where this issue is not an operability concern at this time. The root cause and corrective actions are being addressed via the corrective action program.

Similar reviews of Unit 1 are ongoing.

The NRC resident inspector was notified of this event by the licensee.

HOO Note: Refer to Event #35481, #35537 and #35538.


Power Reactor
Event Number: 35441
Facility: CRYSTAL RIVER
Region: 2     State: FL
Unit: [3] [] []
RX Type: [3] B&W-L-LP
NRC Notified By: RICHARD SWEENY
HQ OPS Officer: FANGIE JONES
Notification Date: 03/05/1999
Notification Time: 10:49 [ET]
Event Date: 03/05/1999
Event Time: 09:51 [EST]
Last Update Date: 03/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
CAUDLE JULIAN (R2)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
3 N Y 100 Power Operation 100 Power Operation
Event Text
STATE NOTIFIED OF A KEMP'S RIDLEY SEA TURTLE RETRIEVED FROM THE PLANT INTAKE WATER

A young healthy Kemp's Ridley sea turtle was taken from the water at the intake of Crystal River Unit 3. The turtle was transported to the Crystal River Mariculture Center. The Florida Department of Environmental Protection was notified of the retrieval of the sea turtle. The turtle will be transported to the Clearwater Marine Science Center.

The licensee plans to notify the NRC Resident Inspector.


Other Nuclear Material
Event Number: 35442
Rep Org: UNIVERSITY RADIOLOGY GROUP
Licensee: UNIVERSITY RADIOLOGY GROUP
Region: 1
City: NEW BRUNSWICK   State: NJ
County:
License #: 29-17475-01
Agreement: N
Docket:
NRC Notified By: BOB TOKARZ
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/05/1999
Notification Time: 12:15 [ET]
Event Date: 03/05/1999
Event Time: 07:30 [EST]
Last Update Date: 03/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
MICHAEL MODES (R1)
DON COOL (NMSS)
Event Text
LOSS AND RECOVERY OF DISPOSABLE RUBBER GLOVES CONTAMINATED WITH LESS THAN 10 MILLICURIES OF IODINE-131.

Last night a cleaning crew accidentally removed a clear plastic bag from the licensee's hot lab and placed the plastic bag into the facilities regular trash system. The trash was picked up by the local trash company early this morning. Before the trash truck arrived at the dump the licensee had stopped the trash truck and recovered the clear plastic bag containing the contaminated disposable rubber gloves. No one was contaminated or received exposure from the contaminated disposable rubber gloves. The plastic bag is back in the hot lab and the licensee's corrective action is not to let the cleaning crew enter the hot lab.

NRC Region 1 (Lodhi) was notified of this event by the NRC Headquarters Operations Officer.


Power Reactor
Event Number: 35443
Facility: SAN ONOFRE
Region: 4     State: CA
Unit: [] [2] [3]
RX Type: [1] W-3-LP,[2] CE,[3] CE
NRC Notified By: CONOSCENTI/PENNA
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/05/1999
Notification Time: 13:26 [ET]
Event Date: 03/05/1999
Event Time: 10:15 [PST]
Last Update Date: 03/05/1999
Emergency Class: ALERT
10 CFR Section:
50.72(a)(1)(i) - EMERGENCY DECLARED
Person (Organization):
DALE POWERS (R4)
ELINOR ADENSAM (NRR)
JOHN DAVIDSON, IAT
ROBERTA WARREN, IAT
ROSANO, IAT
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
2 N Y 100 Power Operation 100 Power Operation
3 N Y 100 Power Operation 100 Power Operation
Event Text
BOMB THREAT. IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY. OUTSIDE AGENCY INVOLVED, (FBI).

LICENSEE NOTIFIED THE NRC RESIDENT INSPECTOR.

AT 1343 ET THE UNITED STATES NUCLEAR REGULATORY COMMISSION ENTERED MONITORING PHASE OF NORMAL MODE.

***COMMISSIONER'S ASSISTANCE BRIEFING ON 03/05/99 AT 1600 ET BRIEFED BY PAT GWYNN (ACTING NRC REGION 4 REGIONAL ADMINISTRATOR)

PARTICIPANTS: IRO (FRANK CONGEL), PAO (SUE GAGNER), STATE PROGRAMS (SOLLENBERGER), CAO (TOM COMBS), EDO OFFICE (TOM HILTZ), DEDE (MAL KNAPP & J. MITCHELL), NRR (SAM COLLINS), CHAIRMAN'S OFFICE (MARK MILLER), COMM. MCGAFFIGAN'S OFFICE (JIM BEALL), COMM. DIAZ'S OFFICE (TONY HSIA), COMM. DICUS' OFFICE (TERENCE CHAN), COMM. MERRIFIELD'S OFFICE (BRIAN McCABE), NMSS (LIZ TEN EYCK), & IAT (ROBERTA WARREN). R4DO (DID NOT PARTICIPATE).

***** UPDATE AT 1527 ET ON 03/05/99 BY MACKINNON **********

THE UNITED STATES NUCLEAR REGULATORY COMMISSION EXITED MONITORING PHASE OF NORMAL MODE AFTER THE ALERT WAS TERMINATED AT 1227 PST.

FEDERAL AGENCIES NOTIFIED OF THE ENTERING AND EXITING OF THE ABOVE EVENT(NOTIFIED BETWEEN APPROXIMATELY 1610 HOURS AND ABOUT 1640 HOURS ON 03/05/99):
USDA (RON GRAHAM), DOE (BRAD ZACHMAN), HHS (JIM RABB), FEMA (CHARLIE BAGWELL), DOT-NRC (LT. HUDSPETH), EPA REGION IX (ROBIN CLEMENS), AND FBI (TOM CASH).

MR. JOSE LUIS DELGADO OF THE MEXICAN NUCLEAR SAFETY COMMISSION WAS NOTIFIED OF THIS EVENT. THE NRC RESIDENT INSPECTOR WAS NOTIFIED OF THIS EVENT UPDATE BY THE LICENSEE.


Power Reactor
Event Number: 35444
Facility: LACROSSE
Region: 3     State: WI
Unit: [1] [] []
RX Type: [1] AC (ALLIS CHAMBERS)
NRC Notified By: MIKE JOHNSEN
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/05/1999
Notification Time: 18:04 [ET]
Event Date: 03/05/1999
Event Time: 15:45 [CST]
Last Update Date: 03/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(i) - DEG/UNANALYZED COND
Person (Organization):
JAMES CREED (R3)
Power Reactor Unit Info
Unit SCRAM Code RX Crit Initial PWR Initial RX Mode Current PWR Current RX Mode
1 N N 0 Decommissioned 0 Refueling
Event Text
SEISMIC CONCERN WITH MAINTAINING SPENT FUEL POOL WATER LEVEL IF THE SPENT FUEL POOL RETURN LINE (ENTERS BOTTOM OF THE SPENT FUEL POOL) RUPTURES DURING A SEISMIC EVENT.

The spent fuel pool has a return line which enters through the bottom of the spent fuel pool. During surveillance testing of the spent fuel pool it was determined that two in series 4 inch check valves (58-26-007, 008; fuel storage well return check valves) have back leakage of between 15 to 16 gallons per minute. Makeup capacity to the spent fuel pool (fuel storage well system) is 5 gallons per minute. If a seismic event (they have never had a seismic event) caused the spent fuel pool return line to rupture the spent fuel pool water inventory could be decreasing between 15 to 16 gallons per minute and regular makeup to the spent fuel pool would be 5 gallons per minute.

The spent fuel pool contains 333 fuel assemblies. The cladding for the spent fuel rods is made of stainless steel and the fuel has been in the spent fuel pool since 1987. The temperature of the spent fuel pool is between 110 to 111 degrees F with no spent fuel pooling cooling.

Contingency actions being taken by the license:

Isolate manual isolation valves as close to the check valves as possible if the line breaks.
Reduce spent fuel pool temperature (this weekend) from 110 degrees to between 70 and 80 degrees F.


An LER will be submitted within 30 days concerning the potential loss of spent fuel pool water inventory via the return line if it is ruptured during a seismic event.